ACCULINK 316x DSU/CSU A December 1996 3160-A2-GB22-10 ACCULINK 316x Data Service Unit/Channel Service Unit(includes Terminal User Interface)Operator’s Guide3160-A2-GB22-10 2nd Edition (December 1996) Changes and enhancements to the product and to the information herein will be documented and issued ...
Safety Instructions B 3160-A2-GB22-10 December 1996 Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product orincluded in the manual. 2. This product is intended to be used with a three-wire grounding type plug - a plugwhich has a grounding pin. Th...
ACCULINK 316x DSU/CSU C December 1996 3160-A2-GB22-10 Notices
Government Requirements D 3160-A2-GB22-10 December 1996 Government Requirements and Equipment Return Certain governments require that instructions pertaining to DSU/CSU and modem connection tothe telephone network be included in the installation and operation manual. Specific instructionsare listed ...
ACCULINK 316x DSU/CSU E December 1996 3160-A2-GB22-10 5. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephonecompany will provide advance notice in order for you to make the nec...
Government Requirements F 3160-A2-GB22-10 December 1996 CAUTION Users should not attempt to make such connectionsthemselves, but should contact the appropriate electricinspection authority, or electrician, as appropriate. The load number is labeled on the equipment. The load number (LN) assigned to ...
i 3160-A2-GB22-10 December 1996 Table of Contents Preface Objectives and Reader Assumptions vii . . . . . . . . . . . . . . . . . . . . . . . . . . . Related Documents vii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reference Documents vii . . . . . . . . . . . . ...
ACCULINK 316x DSU/CSU ii December 1996 3160-A2-GB22-10 3. Operation Operating the Front Panel 3-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring the DSU/CSU 3-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring DS0 Channels 3-34 . . ....
Table of Contents iii 3160-A2-GB22-10 December 1996 List of Figures Figure Page 1-1 3160 DSU/CSU Front Panel 1-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 3164 DSU/CSU Front Panel 1-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Table of Contents v 3160-A2-GB22-10 December 1996 List of Tables Table Page 1-1 Models 3160/3614 DSU/CSUs Rear Panel Connectors 1-7 . . . . . . . . . . . . . . . . . . . . . . 1-2 Auxiliary Backplane Connectors 1-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 S...
vii 3160-A2-GB22-10 December 1996 Preface Objectives and ReaderAssumptions This operator’s guide contains installation and operation information for the ACCULINK r 316x Data Service Unit (DSU)/Channel Service Unit (CSU). Related Documents Contact your sales representative for additional product docu...
1-1 3160-A2-GB22-10 December 1996 Introduction Overview 1-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features 1-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
ACCULINK 316x DSU/CSU 1-2 December 1996 3160-A2-GB22-10 • Independently selectable DTE interfaces (V.35,EIA-530A, V.11, and/or RS449/422). • Flexible timing source, available from the T1 network interface, the DSX-1 T1 interface, atleast one of the synchronous DCE data ports, aninternal clock, or an...
Introduction 1-3 3160-A2-GB22-10 December 1996 Front Panel Emulation The 3160/3164 DSU/CSU offers the same functionality through Front Panel Emulation software as that providedby the DSU/CSU front panel. The DSU/CSU can either belocally attached to a 286 or higher PC, or remotelythrough a local 3160...
ACCULINK 316x DSU/CSU 1-4 December 1996 3160-A2-GB22-10 SNMP is an industry-standard network management system that is used to monitor network performance andstatus, and to report alarms (i.e., traps). To function,SNMP requires a manager consisting of a softwareprogram housed within a workstation; a...
Introduction 1-7 3160-A2-GB22-10 December 1996 Table 1-1 Models 3160/3164 DSU/CSUs Rear Panel Connectors Connector Name Function POWER A modular connector that supplies power to the DSU/CSU. AUX PORT An auxiliary communications port for future use. COM PORT A communications port that provides access...
ACCULINK 316x DSU/CSU 1-8 December 1996 3160-A2-GB22-10 Carrier-Mounted Model 3161 DSU/CSU The 3161 DSU/CSU is a circuit card that is installed into the 3000 Series Carrier. A single carrier can house upto 16 DSU/CSUs; the DSU/CSUs are controlled by thecarrier’s Shared Diagnostic Control Panel (SDCP...
2-1 3160-A2-GB22-10 December 1996 Installation Overview 2-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Planning 2-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
ACCULINK 316x DSU/CSU 2-2 December 1996 3160-A2-GB22-10 In addition, a 3160 DSU/CSU, acting as an SNMP agent, can be connected to and managed from an SNMPmanagement system in one of two ways: • Serial connection via the COM or MODEM port toan SNMP management system using eitherPoint-to-Point Protoco...
Installation 2-3 3160-A2-GB22-10 December 1996 FRACTIONAL T1 NETWORK T1 T1 T1 LAN ROUTER LAN ROUTER LAN ROUTERS 496-14313a-01 ACCULINK 3160/3164 DSU/CSU ACCULINK 3160/3164 DSU/CSU ACCULINK 3160/3164 DSU/CSU Figure 2-3. Multiport T1 DSU/CSU in a Fractional T1 Network Configuration Figure 2-4. Central...
ACCULINK 316x DSU/CSU 2-4 December 1996 3160-A2-GB22-10 Figure 2-5. Serial Connection to SNMP Figure 2-6. Serial Connection through a Router to SNMP
Installation 2-5 3160-A2-GB22-10 December 1996 Box Contents The 3160/3164 DSU/CSU product arrives in a single box and should contain the following: • One 3160/3164 DSU/CSU standalone unit • One 14.5 foot VF cable • One power transformer • One ACCULINK 3160/3164 DSU/CSU ReferenceCard • One ACCULINK 3...
ACCULINK 316x DSU/CSU 2-6 December 1996 3160-A2-GB22-10 5. If you intend to manage the 3160/3164 DSU/CSU with SNMP, cable either the COM or MODEMport (as appropriate for your configuration). Then,configure the SNMP management link. SeeChapter 3, Operation, and Appendix C,Configuration Options, for m...
Installation 2-7 3160-A2-GB22-10 December 1996 Installing the Single – ā 48 Vdc Power Supply To install the 3160/3164 DSU/CSU using a single source – 48 Vdc power supply, refer to Figure 2-8 and usethe following procedure. To install the – 48 Vdc single source power supply, 1. Connect the black and ...
ACCULINK 316x DSU/CSU 2-8 December 1996 3160-A2-GB22-10 Installing the Redundant – ā 48 Vdc Power Supply To install the 3160/3164 DSU/CSU using a redundant – 48 Vdc power supply, refer to Figure 2-9 and use thefollowing procedure. To install the redundant – 48 Vdc power supply, 1. Connect the black ...
Installation 2-9 3160-A2-GB22-10 December 1996 Power-Up Self-Test After you connect the 3160/3164 DSU/CSU to a power outlet, the power-up self-test is performed to ensure thatthe unit is in good working order. The DSU/CSUperforms this test on itself upon power-up or after a devicereset unless it has...
ACCULINK 316x DSU/CSU 2-10 December 1996 3160-A2-GB22-10 Differences Using the Async Terminal: To monitor the self-test from the async terminal, select Health, TestStatus, and Self Test Results from the main/status menu.The full screen display capacity provides a complete testresults screen that inc...
ACCULINK 316x DSU/CSU 2-12 December 1996 3160-A2-GB22-10 6. Enter the desired ID. Press F1 (Up) and F2 (Down) to scroll up and down through the validcharacters/numbers for the customer ID. Validcharacters are 0 through 9, #, -, ., /, A to Z, andblank space. Press F3 (Save) to save the ID. F1 CustID=...
Installation 2-13 3160-A2-GB22-10 December 1996 To set a password, 1. Press the key on the top-level menu screen to bring the Ctrl branch onto the front panel LCD. F1 DSU ESFStat Test Cnfig F2 F3 2. Press F3 to select Ctrl from the top-level menu screen. F1 DSU ESFTest Cnfig Ctrl F2 F3 3. Press the ...
ACCULINK 316x DSU/CSU 2-14 December 1996 3160-A2-GB22-10 3160/3164 DSU/CSU Cabling The 3160/3164 DSU/CSU is supplied with an ac power transformer and a VF cable for the integral modem. Youmust provide the DTE cable to connect the DTE to theDSU/CSU. Optional cables you can order from the company are ...
Installation 2-19 3160-A2-GB22-10 December 1996 NOTE This page of the manual is self-supporting and can be removed toprevent unwanted knowledge of thesecurity access levels and theirselection. Changing User Interface Access Security To change user interface access security, 1. Press the key two time...
Operation 3-3 3160-A2-GB22-10 December 1996 Operating the Front Panel The 3160 DSU/CSU front panel (Figure 3-1) consists of an LCD that displays messages, a keypad, 12 LEDs,and six test jacks. The Model 3161 CSU faceplatecontains these same 12 LEDs and six test jacks (seeFigure 3-2), however, the LC...
Operation 3-5 3160-A2-GB22-10 December 1996 LCD The LCD displays messages and the front panel menu in an easy-to-read English format, including easilyrecognizable abbreviations and symbols (Figure 3-4). F1 LCD F2 F3 Figure 3-4. LCD The LCD displays two types of data: • Messages such as alarms, comma...
ACCULINK 316x DSU/CSU 3-6 December 1996 3160-A2-GB22-10 Use the Function (F1, F2, F3) keys to make selections from the choices presented on the second line of the LCD.When this line presents choices, it is generally dividedinto three sections, each displayed directly above one ofthe Function keys. W...
Operation 3-7 3160-A2-GB22-10 December 1996 Table 3-1 System LEDs Name Color Meaning OK Green Indicates the current operational state of the DSU/CSU. ON : The DSU/CSU is operational and has power. OFF : The DSU/CSU is performing a power-up self-test or a system failure has occurred. BLINKING : A sof...
ACCULINK 316x DSU/CSU 3-8 December 1996 3160-A2-GB22-10 Table 3-2 NETWORK Interface LEDs Name Color Meaning SIG Green Monitors the signal being received from the network. ON : A recoverable signal is being received from the network. OFF : The signal cannot be recovered from the network (a Loss of Si...
Operation 3-9 3160-A2-GB22-10 December 1996 Table 3-3 DSX-1 Drop/Insert Port LEDs Name Color Meaning SIG Green Monitors the signal being received from the DSX-1. ON : A recoverable signal is being received from the DSX-1. OFF : The signal cannot be recovered from the DSX-1 (a Loss of Signal conditio...
ACCULINK 316x DSU/CSU 3-10 December 1996 3160-A2-GB22-10 Table 3-4 Data Port LEDs Name Color Meaning DTR Green Monitors the state of interchange circuit CD (CCITT 108/1, /2) – DTE Ready receivedfrom the DTE. ON : DTR is being asserted by the DTE. OFF : DTR is not being asserted. TXD Yellow Monitors ...
Operation 3-11 3160-A2-GB22-10 December 1996 Displaying LED Conditions on the Front Panel The same conditions monitored by the front panel LEDs can also be monitored by the LED command. Thiscommand is most useful when the DSU/CSU is beingaccessed remotely. NOTE No LEDs are shown on the PC’sfront pan...
ACCULINK 316x DSU/CSU 3-12 December 1996 3160-A2-GB22-10 Customer ID: New Cust main/status/ledsModel: ACCULINK XXXX LEDs Test NET T1 Sig OOF Alrm EER DTE T1 Sig OOF Alrm PDV BPV Port1 DTR TXD RXD CTS RTS Refresh Main Previous Cntrl–x to Disconnect Port2 DTR TXD RXD CTS RTS Port3 DTR TXD RXD CTS RTS ...
Operation 3-13 3160-A2-GB22-10 December 1996 Figure 3-8 shows an example of this selection screen. You can set the front panel LED display to be DTE or aport. Customer ID: New Cust main/control/miscellaneousModel: ACCULINK XXXX Save Main Previous Cntrl–x to Disconnect Miscellaneous Control Options F...
ACCULINK 316x DSU/CSU 3-14 December 1996 3160-A2-GB22-10 Table 3-5 Front Panel Emulation Screen Icons Icon Name Meaning Help Help Click on this pull-down menu to display onlineHELP. Options Options Click on this pull-down menu to access thefollowing options: Phone Numbers F1 Open COM Window F2 Chang...
ACCULINK 316x DSU/CSU 3-16 December 1996 3160-A2-GB22-10 Table 3-6 Test Jack Functions Test Jack Name Function Net In(Network In) A break-in and test jack that allows a signal to be inserted toward the network byexternal test equipment. The signal is inserted on the DSX-1 side of theDSU/CSU. Net Out...
Operation 3-17 3160-A2-GB22-10 December 1996 Configuration Procedures Use the Configuration (Cnfig) branch of the front panel menu tree to display or change DSU/CSU configurationoptions (see Figure 3-14). Figure 3-14. Configuration Branch for the Front Panel
ACCULINK 316x DSU/CSU 3-18 December 1996 3160-A2-GB22-10 Differences using the Async Terminal: Figure 3-15 shows the Configuration branch for the async terminalinterface. Figure 3-15. Configuration Branch for the Async Terminal Displaying/Editing Configuration Options To display/edit configuration o...
Operation 3-19 3160-A2-GB22-10 December 1996 4. From the Edit screen, select the functional group you want to edit by pressing the appropriatefunction key. Use the scroll keys, if necessary. F1 Edit:DTE Port NET F2 F3 The configuration options for the selectedfunctional group appear on the front pan...
ACCULINK 316x DSU/CSU 3-20 December 1996 3160-A2-GB22-10 The bottom of the screen shows the addition of the Edit and Save functions. The Save To: field can be populated with Active or Cust to enable a 1-step copy of one configuration optionset into another when the Save function is subsequentlyselec...
Operation 3-21 3160-A2-GB22-10 December 1996 To protect you from accidentally exiting an edit session before saving your changes, the system prompts SaveOptions? if you select either Main or Cntrl-x from anedit screen (see Figure 3-18). If you respond No, thesystem exits without saving the changes. ...
ACCULINK 316x DSU/CSU 3-22 December 1996 3160-A2-GB22-10 Differences Using the Async Terminal: To select a port, use the Ports selection from the main/configuration/editmenu. The subsequent ports menu provides a list of theconfigured ports (see Figure 3-19). Prt1 Options Value Port Type E530, V.35, ...
Operation 3-23 3160-A2-GB22-10 December 1996 To Copy to One or All Ports To copy the configuration options to one or all ports, 1. Press F3 to select Cnfig from the top-level menu screen. F1 DSU ESFStat Test Cnfig F2 F3 2. Select the configuration option set to be copied into the Edit area by using ...
ACCULINK 316x DSU/CSU 3-24 December 1996 3160-A2-GB22-10 Configuring the 3160/3164 DSU/CSU forSNMP Management To configure a 3160/3164 DSU/CSU for management by an SNMP management system you must, • Select and configure the port (COM or MODEM)providing the link to the SNMP managementsystem. • Set th...
ACCULINK 316x DSU/CSU 3-26 December 1996 3160-A2-GB22-10 3. Press F1 to select Edit. F1 Choose Funct:Edit Save F2 F3 4. Press the key from the Edit screen to display the User selection. F1 Edit:DTE Port NET F2 F3 5. Press F3 to select User. F1 Edit:Chan Gen User F2 F3 6. Press the F1 (Next) key unti...
ACCULINK 316x DSU/CSU 3-28 December 1996 3160-A2-GB22-10 9. Use the and keys to position the cursor under the digit you want to change. Press F1 (Up)to increment the digit or F2 (Down) to decrementthe digit. In this example, you would press once to place the cursor under the middle digit inthe first...
Operation 3-29 3160-A2-GB22-10 December 1996 2. Select the configuration option set to be copied into the Edit area by using the appropriatefunction key. Use the scroll keys, if necessary. F1 Load from:Activ Cust Fact1 F2 F3 3. Press F1 to select Edit. F1 Choose Funct:Edit Save F2 F3 4. Press the ke...
Operation 3-31 3160-A2-GB22-10 December 1996 10. When you are through changing the community name, you must press F3 (Save) to save the value.Otherwise, the original value will be retained. F1 newnameUp Down Save F2 F3 11. Press the F1 (Next) key until the Access 1 configuration option appears. F1 C...
ACCULINK 316x DSU/CSU 3-32 December 1996 3160-A2-GB22-10 Selecting the Number of Trap Managers If you intend to issue traps to an SNMP manager(s) from this device, you must specify the number of SNMPmanagers that are to receive the traps. To specify the number of SNMP managers to receive traps from ...
ACCULINK 316x DSU/CSU 3-34 December 1996 3160-A2-GB22-10 8. Press F2 (Edit) to edit the IP address. You have the option of using F3 (Clear) to reset the IP addressto the factory default 000.000.000.000. Refer tothe Setting the IP Address section earlier in thischapter for more information on setting...
ACCULINK 316x DSU/CSU 3-36 December 1996 3160-A2-GB22-10 Network T1 Interface Network Channel Allocation N1 D1 N2 D2 N3 D3 N4 D4 N5 D5 N6 N7 Prt1 N8 Prt1 N9 Prt1 N10 Prt1 N11 Prt1 N12 Prt1 N13 Prt3 N14 Prt2 N15 Prt2 N16 Prt2 N17 Prt2 N18 Prt2 N19 Prt2 N20 Prt2 N21 Prt2 N22 Prt2 N23 Prt2 N24 Prt3 All...
Operation 3-37 3160-A2-GB22-10 December 1996 DTE Chan Config Assign: (N1 – 24) Voice (RBS or Data) D1 N1 RBS D2 N2 RBS D3 N3 RBS D4 N4 RBS D5 N5 Data D6 D7 D8 D9 D10 D11 D12 D13 D14 D15 D16 D17 D18 D19 D20 D21 D22 D23 D24 Figure 3-26. DS0 Channels Containing RBS Information Worksheet
ACCULINK 316x DSU/CSU 3-38 December 1996 3160-A2-GB22-10 Port Chan Conf Options Value Assign To NET, DTE Assign By Block, ACAMI, Chan If Assign By Block Port Rate Nx64: 64, 128, 192, 256, 320, 384, 448, 512, 576,640, 704, 768, 832, 896, 960, 1024, 1088, 1152,1216, 1280, 1344, 1408, 1472, 1536 Nx56: ...
ACCULINK 316x DSU/CSU 3-40 December 1996 3160-A2-GB22-10 Displaying DS0 Channel Assignments Use the Display command for channel configuration to view how the DS0 channels for either the DSX-1Drop/Insert T1 interface or the Network interface arecurrently allocated. The display appears on the front pa...
Operation 3-41 3160-A2-GB22-10 December 1996 7. From the Display Chan screen, press F1 (NET) to display the channels allocated to the Network T1interface. F1 Display Chan:NET DTE F2 F3 NOTE If the DSX-1 Drop/Insert T1Network interface is disabled, theNetwork T1 interface channelsare displayed immedi...
ACCULINK 316x DSU/CSU 3-42 December 1996 3160-A2-GB22-10 Allocating Data Ports You have the capability of assigning a specific port (Prt1...Prt2 for Models 3160/3161, Prt1...Prt4 for Model 3164) to DS0 channels on either the Networkinterface or the DSX-1 Drop/Insert T1 interface using theconfigurati...
Operation 3-43 3160-A2-GB22-10 December 1996 3. Press F1 to select Edit. F1 Choose Funct:Edit Save F2 F3 4. Press the key from the Edit screen to display the Chan selection. F1 Edit:DTE Port NET F2 F3 5. Press F3 to select Chan. F1 Edit:DTEPort NET Chan F2 F3 6. From the Channel Config screen, press...
ACCULINK 316x DSU/CSU 3-44 December 1996 3160-A2-GB22-10 3. Use the or key to scroll the desired port rate onto the screen. Rates scroll in groups ofthree. Available selections depend on the currentbase rate selected for the port. Press thecorresponding Function key to select the port rate.Then, sel...
ACCULINK 316x DSU/CSU 3-46 December 1996 3160-A2-GB22-10 2. Select the configuration option set to be copied into the Edit area by using the appropriatefunction key. Use the scroll keys, if necessary. F1 Load from:Activ Cust Fact1 F2 F3 3. Press F1 to select Edit. F1 Choose Funct:Edit Save F2 F3 4. ...
Operation 3-47 3160-A2-GB22-10 December 1996 Differences Using the Async Terminal: To allocate DS0 channels from the DSX-1 Drop/Insert T1 interface to theNetwork interface, select DTE Assign from themain/configuration/edit/channel menu. Figure 3-30 showsan example of the DTE Assignment screen. Custo...
ACCULINK 316x DSU/CSU 3-48 December 1996 3160-A2-GB22-10 Clearing DS0 Channel Allocation You can clear (unallocate) all the DS0 channels currently allocated to either the Network T1 interface orthe DSX-1 Drop/Insert T1 interface. To clear DS0 channel allocation, 1. Press F3 to select Cnfig from the ...
Operation 3-49 3160-A2-GB22-10 December 1996 Timing The 316x DSU/CSU provides the ability to select a master clock (timing) source that is used to synchronizeall of the T1 and data port interfaces on the DSU/CSU.When a master clock source is selected, the DSU/CSUwill synchronize to the master clock ...
ACCULINK 316x DSU/CSU 3-50 December 1996 3160-A2-GB22-10 Configuring for Network Timing Example To configure network timing, 1. Press F3 to select Cnfig from the top-level menu screen. F1 DSU ESFStat Test Cnfig F2 F3 2. Select the configuration option set to be copied into the Edit area by using the...
Operation 3-51 3160-A2-GB22-10 December 1996 Configuring for External Timing Example To configure network timing, 1. Press F3 to select Cnfig from the top-level menu screen. F1 DSU ESFStat Test Cnfig F2 F3 2. Select the configuration option set to be copied into the Edit area by using the appropriat...
Operation 3-53 3160-A2-GB22-10 December 1996 8. Press F2 to select Enab. F1 MasterCom:DisabNext Enab Disab F2 F3 Checking the Status of theDSU/CSU You can request various types of status information from the 316x DSU/CSU’s front panel. Access thisinformation from the Status branch of the front panel...
ACCULINK 316x DSU/CSU 3-54 December 1996 3160-A2-GB22-10 Table 3-9 Health and Status Messages Message Description LOS at Net A Loss Of Signal (LOS) condition (declared after 175 consecutive zeros) has been detected onthe network interface. The condition is cleared when the density of ones to zeros r...
Operation 3-55 3160-A2-GB22-10 December 1996 Displaying Device Health and Status To display device health and status, 1. Press F1 to select Stat from the top-level menu screen. F1 DSU ESFStat Test Cnfig F2 F3 2. From the Status screen, press F1 to select DevHS. F1 Status:DevHS STest Perf F2 F3 Alarm...
ACCULINK 316x DSU/CSU 3-56 December 1996 3160-A2-GB22-10 Table 3-10 Self-Test Health Messages Message Description Passed No problems found during power-up. CPU fail Central Processing Unit failed internal testing. DTE T1 fail Unit failed to internally loop data on the DTE circuit. Failure xxxxxxxx A...
Operation 3-57 3160-A2-GB22-10 December 1996 Performance Report Network performance is continuously monitored and maintained in internal memory registers when the networkinterface is configured for ESF operation. The DSU/CSUmaintains two sets of registers: Carrier Network InterfaceRegisters (Telco) ...
Operation 3-59 3160-A2-GB22-10 December 1996 Displaying User Performance Registers To display a Performance Report on the front panel LCD, 1. Press F1 to select Stat from the top-level menu screen. F1 DSU ESFStat Test Cnfig F2 F3 2. From the Status screen, press F3 to select Perf. F1 Status:DevHS ST...
ACCULINK 316x DSU/CSU 3-60 December 1996 3160-A2-GB22-10 Differences Using the Async Terminal: To display a performance report, select Telco Performance or UserPerformance from the main/status menu. Select Refreshto force an update to these screens. Figure 3-36 shows anexample of the Telco Performan...
Operation 3-61 3160-A2-GB22-10 December 1996 3. From the Control screen, press to scroll ClrUsr on the screen. F1 Control:Call Rel LED F2 F3 4. Press F3 to select ClrUsr. F1 Control:Rel LED ClrUsr F2 F3 5. From the Clear Registers screen, press F1 to clear the User registers or press F2 if you have ...
ACCULINK 316x DSU/CSU 3-62 December 1996 3160-A2-GB22-10 Acquiring/Releasing the Active PhysicalInterface You can access a user interface from either the front panel, the SDCP (for 3161 DSU/CSUs only), theMODEM port (for 3160/3164 DSU/CSUs only), or theCOM port. The 316x DSU/CSU allows only one phys...
Operation 3-63 3160-A2-GB22-10 December 1996 3. From the Control screen, press F2 to select Rel. F1 Control:Call Rel LED F2 F3 The active physical interface is released. A screenwith this message appears. No physical interface isactive until input is received from a physicalinterface. F1 Ft. Panel:R...
Operation 3-65 3160-A2-GB22-10 December 1996 6. When the number of the desired directory appears on the screen, press F3 (Dial) to place the call. Differences Using the Async Terminal: To initiate a call at the local DSU/CSU, select Call Setup from themain/control menu. Figure 3-40 shows an example ...
ACCULINK 316x DSU/CSU 3-66 December 1996 3160-A2-GB22-10 Disconnecting the Modem Connection The Disconnect command enables you to force a disconnect of an active modem connection from the frontpanel of the DSU/CSU. This command is only availablewhen the DSU/CSU modem is connected, either throughalar...
Operation 3-67 3160-A2-GB22-10 December 1996 Differences Using the Async Terminal: To disconnect an established modem connection, select Disconnect fromthe main/control/call_setup screen. Figure 3-41 shows anexample of the screen that appears. The Async Terminalfeature does not support the pass-thro...
ACCULINK 316x DSU/CSU 3-68 December 1996 3160-A2-GB22-10 6. Press F3 (Edit) to change the displayed directory’s phone number (phone numbers can be up to 40characters). If you select Edit, the Edit screenappears. F1 1: xxxxxxxxxxxxxxxxxNext Prev Edit F2 F3 7. Use the and keys to position the cursor u...
Operation 3-69 3160-A2-GB22-10 December 1996 Deactivating the Alarm Relay The Alarm Cut-off command forces a deactivation of the alarm relay on the 3000 Series Carrier during an alarmcondition. Since this function only affects the 3000 SeriesCarrier, it is only available for Model 3161 DSU/CSUs.The ...
ACCULINK 316x DSU/CSU 3-70 December 1996 3160-A2-GB22-10 3. Double click on the Front Panel icon that appears after the Front Panel Emulation program isinstalled on the PC. The Front Panel Emulationscreen appears. 4. Enter the Com Port and Speed from the drop-down selection list boxes. The Com Port ...
Operation 3-71 3160-A2-GB22-10 December 1996 Activating Interface Option Changes After the async terminal configuration options are set, the changes must be saved and made active. Depending onyour preference, changes are saved to the Customer (Cust)Configuration option set which, in turn, must be wr...
ACCULINK 316x DSU/CSU 3-72 December 1996 3160-A2-GB22-10 Async Terminal feature displays all selections for a menuor configuration option in full screen format withfunctions available to operate on the screen informationappearing at the bottom of the screen. All functions operate the same throughout...
Operation 3-73 3160-A2-GB22-10 December 1996 Table 3-14 Hard-Key Representations for Edit Screens Key Usage Tab key Moves between fields. Backspace Moves cursor one positionto the left. Spacebar Steps through validselections in a field. Delete key Deletes character atcurrent cursor position. Carriag...
ACCULINK 316x DSU/CSU 3-74 December 1996 3160-A2-GB22-10 Display screens support the following Function keys for invoking an operation (Figure 3-16): Table 3-16 Function Representations for Display Screens Function Key Usage Refresh Updates the display to thecurrent period. Up main/status/performanc...
4-1 3160-A2-GB22-10 December 1996 Maintenance Overview 4-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting 4-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
ACCULINK 316x DSU/CSU 4-2 December 1996 3160-A2-GB22-10 Alarms The 316x DSU/CSU monitors alarm conditions occurring on either the network interface or the DSX-1Drop/Insert port (DTE). For Model 3160/3164DSU/CSUs, you can route these alarms to the MODEMport, the COM port, or both. Each alarm is prece...
Maintenance 4-3 3160-A2-GB22-10 December 1996 Test Commands The test commands enable you to run loopbacks and test patterns on the DSU/CSU, and to test the front panelLEDs. These tests can help you isolate areas of trouble incase you are having problems with your 316x DSU/CSU.Access all Test command...
ACCULINK 316x DSU/CSU 4-4 December 1996 3160-A2-GB22-10 When you select T1 Interface Loopbacks and Patterns, the subsequent screen displays the RemoteLoopback, Local Loopback, Send, Monitor, and Abortoperations that are available to run on the T1 interface, asshown in Figure 4-2. Likewise, from one ...
Maintenance 4-5 3160-A2-GB22-10 December 1996 Sending a V.54/ANSI FT1Activation/Deactivation To send a V.54 or ANSI FT1 Activation or Deactivation loopback sequence to the far-end DSU/CSU, 1. Press F2 to select Test from the top-level menu screen. F1 DSU ESFStat Test Cnfig F2 F3 2. From the Test scr...
ACCULINK 316x DSU/CSU 4-6 December 1996 3160-A2-GB22-10 Table 4-2 Valid Loopback Combinations LLB PLB DLB RLB DCLB DTLB LLB N/A NO YES YES NO YES PLB NO N/A YES NO NO YES DLB YES YES N/A NO YES YES RLB YES NO NO N/A NO YES DCLB NO NO YES NO YES (on separate ports) YES (on separate ports) DTLB YES YE...
Maintenance 4-7 3160-A2-GB22-10 December 1996 Starting a Payload Loopback The Payload Loopback command (PLB) loops the received signal on the network interface back to thenetwork. The signal is looped back as close to the DSX-1Drop/Insert port (DTE) as possible (after it has passedthrough the framin...
ACCULINK 316x DSU/CSU 4-8 December 1996 3160-A2-GB22-10 To perform a DTE loopback, 1. Press F2 to select Test from the top-level menu screen. F1 DSU ESFStat Test Cnfig F2 F3 2. From the Test screen, press F2 to select Lpbk. F1 Test:Rlpbk Lpbk Ptrns F2 F3 3. From the Loopback screen, press once to di...
Maintenance 4-9 3160-A2-GB22-10 December 1996 4. Press F3 to select RLB. F1 Loopback:PLB DLB RLB F2 F3 Test Started appears on Line 2. If a Repeaterloopback is already in progress, the AlreadyActive message appears. If an invalid combinationof loopbacks is in progress, the error messageInvalid Test ...
ACCULINK 316x DSU/CSU 4-10 December 1996 3160-A2-GB22-10 Starting a Data Terminal Loopback The Data Terminal loopback command (DTLB) loops the data received from the selected port, for all DS0channels allocated to the port, back out the port. Thisloopback occurs after the data passes through the por...
Maintenance 4-11 3160-A2-GB22-10 December 1996 DTE-initiated Loopbacks The 316x DSU/CSU complies with the V.54 standard for initiating local and remote loopbacks. The localloopback initiates a DTLB, and the remote loopbackinitiates a DCLB. DTLBs and DCLBs can be initiated by the DTEs attached to por...
ACCULINK 316x DSU/CSU 4-12 December 1996 3160-A2-GB22-10 Test Patterns Use the Test Pattern commands to send, monitor, and abort transmission of test patterns on the DSU/CSUnetwork. Available test patterns are: • QRSS – A Quasi-Random Signal Sourceapproximating live data that can be monitored forlog...
Maintenance 4-13 3160-A2-GB22-10 December 1996 Table 4-3 Valid Send Test Pattern Combinations QRSS (Network) QRSS (Port) 1 in 8 (Network) 511 (Port) QRSS (Network) N/A NO NO NO QRSS (Port) NO YES (on separate ports) N/A YES (on separate ports) 1 in 8 (Network) NO NO N/A NO 511 (Port) NO N/A N/A YES ...
ACCULINK 316x DSU/CSU 4-14 December 1996 3160-A2-GB22-10 Aborting Test Patterns Use the Abort command to stop all test patterns or any selected test pattern active on the DSU/CSU. To abort test patterns, 1. Press F2 to select Test from the top-level menu screen. F1 DSU ESFStat Test Cnfig F2 F3 2. Fr...
Maintenance 4-15 3160-A2-GB22-10 December 1996 2. From the Test screen, press once to display the Lamp selection on the screen. F1 Test:Rlpbk Lpbk Ptrns F2 F3 3. From the Test screen, press F3 to select Lamp. F1 Test:Lpbk Ptrns Lamp F2 F3 4. From the Lamp Test screen, press F2 to select Start. F1 La...
ACCULINK 316x DSU/CSU 4-16 December 1996 3160-A2-GB22-10 Displaying DSU/CSU Test Status Use the Test Status command to display the active tests for the DSU/CSU. Status messages that can display on thefront panel LCD are listed in Table 4-4. Table 4-4 Test Status Messages Message Description No Test ...
Maintenance 4-17 3160-A2-GB22-10 December 1996 To display test status, 1. Press F1 to select Stat from the top-level menu screen. F1 DSU ESFStat Test Cnfig F2 F3 2. From the Status screen, press the key once to display the TStat selection. F1 Status:DevHS STest Perf F2 F3 3. Press F3 to select TStat...
ACCULINK 316x DSU/CSU 4-18 December 1996 3160-A2-GB22-10 3. From the Control screen, press the key until the Reset selection appears on the screen. F1 Control:Call Rel LED F2 F3 4. Press F2 to select Reset. F1 Control:ClrUsr Reset F2 F3 5. From the Device Reset screen, press F1 to initiate a reset o...
A-1 3160-A2-GB22-10 December 1996 Front Panel Menu A
B-1 3160-A2-GB22-10 December 1996 Technical Specifications The technical specifications for the Models 3160/3164 DSU/CSUs are listed in Table B-1. The technicalspecifications for the Model 3161 DSU/CSU are listed inTable B-2. Table B-1 (1 of 2) ACCULINK Models 3160/3164 DSU/CSUs Technical Specificat...
Technical Specifications B-3 3160-A2-GB22-10 December 1996 Table B-2 (1 of 2) ACCULINK Model 3161 DSU/CSU Technical Specifications Specifications Criteria POWER REQUIREMENTSSixteen 3161 DSU/CSUs, plus SDU,SDCP and fan module 115 Vac Power Supply– 48 Vdc Power Unit 90 to 132 Vac, 60 Hz ± 3 (2.4 amp, ...
C-1 3160-A2-GB22-10 December 1996 Configuration Options Functional Grouping C-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Context-Sensitive Menu C-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
ACCULINK 316x DSU/CSU C-2 December 1996 3160-A2-GB22-10 Context-Sensitive Menu This DSU/CSU is an intelligent device that displays only those options that are valid for the currentconfiguration. Therefore, you will only be presented withmenu choices that are consistent with the currentconfiguration ...
ACCULINK 316x DSU/CSU C-4 December 1996 3160-A2-GB22-10 Port Configuration Options Table C-2 (1 of 3) Port Configuration Options Port Type: E530 (Factory 1) V.35 (Factory 2)Next E530 V.35 RS449 Prev Data Port Type. Allows selection of the data port type. E530 – Configures the port as an EIA-530A com...
Configuration Options C-7 3160-A2-GB22-10 December 1996 Network InterfaceConfiguration Options Table C-3 (1 of 2) Network Interface Configuration Options NET Framing: ESF (Factory 1) D4 (Factory 2)Next D4 ESF Prev Network Line Framing Format. The framing format to be used on the Network T1 interface...
Configuration Options C-9 3160-A2-GB22-10 December 1996 Channel ConfigurationOptions The Channel configuration options are divided into two tables as follows: • DTE Channel Configuration Options (Table C-4) • Data Port Channel Configuration Options(Table C-5) Table C-4 DTE Channel Configuration Opti...
ACCULINK 316x DSU/CSU C-10 December 1996 3160-A2-GB22-10 Table C-5 (1 of 2) Data Port Channel Configuration Options Prt(1, 2, 3, or 4): Data Port Channel. Assigns the port to DS0 channels on either the Network T1 interface or the DSX-1 Drop/Insert T1interface. When you select a port, some of the fol...
ACCULINK 316x DSU/CSU C-12 December 1996 3160-A2-GB22-10 General Configuration Options Table C-6 General Configuration Options Gen Yellow: EnabNext Enab Disab Prev Generate Yellow Alarm Signals. Determines whether the DSU/CSU generates yellow alarm signals on the Network andDTE Drop/Insert T1 Interf...
Configuration Options C-13 3160-A2-GB22-10 December 1996 User Interface ConfigurationOptions Table C-7 (1 of 4) User Interface Configuration Options Self-Test: EnabNext Enab Disab Prev Initial Self-Test. Specifies whether the DSU/CSU performs a device self-test at power-up and after a device reset. ...
Configuration Options C-17 3160-A2-GB22-10 December 1996 Alarm Configuration Options Table C-8 (1 of 3) Alarm Configuration Options Alrm Msg: DisabNext Disab Modem Com Both Prev Alarm Messages. Controls the generation and routing of alarm messages to an ASCII terminal/printer attached to eitherthe M...
ACCULINK 316x DSU/CSU C-20 December 1996 3160-A2-GB22-10 SNMP Configuration Options The SNMP configuration options are divided into two tables as follows: • General SNMP Configuration Options (Table C-9) • SNMP Trap Configuration Options (Table C-10) Table C-9 (1 of 2) General SNMP Configuration Opt...
ACCULINK 316x DSU/CSU C-22 December 1996 3160-A2-GB22-10 Table C-10 (1 of 2) SNMP Trap Configuration Options Num Trap Mgrs: 1Next 1 2 3 4 5 6 Prev Number of Trap Managers. Specifies the number of trap managers supported by the unit. NOTE: You must configure an IP address for each trap manager that i...
D-1 3160-A2-GB22-10 December 1996 Pin Assignments Cables D-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T1 Network Connector Interface D-1 . . . . . . . . . . . . . . . . . . . . . . . . . . ...
ACCULINK 316x DSU/CSU D-2 December 1996 3160-A2-GB22-10 Figure D-1. T1 Line Interface Cable with RJ48C Connector (Feature Number 3100-F1-500) Table D-1 T1 Network Interface Connector (J4) Signal Pin Number Receiver Ring 1 Receiver Tip 2 Transmitter Ring 4 Transmitter Tip 5
ACCULINK 316x DSU/CSU D-4 December 1996 3160-A2-GB22-10 DSX-1 Port DTE Interface This cable is typically supplied by a DTE vendor and is a 22 AWG solid, individually shielded twisted pair cablewith drain wire (Figure D-3). The cable connector is aDB15 plug. Be sure to connect the shield ground only ...
Pin Assignments D-5 3160-A2-GB22-10 December 1996 Integral Modem Service PortInterface The integral modem VF cable is a 14.5-foot, 26 AWG, 4-conductor keyed cable with an RJ11C-like plugconnector (Figure D-4). This cable is supplied with your3160/3164 DSU/CSU. The integral modem service portconnecto...
ACCULINK 316x DSU/CSU D-6 December 1996 3160-A2-GB22-10 AUX Port Interface The Auxiliary (AUX) port is reserved for future use for extended management functions. No connection should bemade to this port. The port connector is an 8-positionkeyed modular jack (Table D-5). Table D-5 Extended Management...
Pin Assignments D-7 3160-A2-GB22-10 December 1996 COM Port Interface The COM port connects to either a PC for front panel emulation or to an ASCII terminal or printer for alarms.The COM port-to-PC cable is a 14-foot, 26 AWG,8-conductor cable with an 8-position modular plug keyedconnector and a DB9 s...
Pin Assignments D-9 3160-A2-GB22-10 December 1996 EIA-530A DB25 Port InterfaceConnector The EIA-530A Port Interface connector information is shown in Table D-7 and Figure D-7. Table D-7 EIA-530A Port Interface Connector Signal Circuit Mnemonic CCITT Number Direction Pin Shield — — — 1 Signal Common ...
ACCULINK 316x DSU/CSU D-10 December 1996 3160-A2-GB22-10 RS449 Port InterfaceConnector The RS449 Port Interface connector information is shown in Table D-8 and Figure D-7. Table D-8 RS449 Port Interface Connector Signal Circuit Mnemonic CCITT Number Direction Pin Shield — — — 1 Signal Ground SG 102A...
ACCULINK 316x DSU/CSU D-12 December 1996 3160-A2-GB22-10 V.35 Port Interface Connector The V.35 Port Interface connector information is shown in Table D-9 and Figure D-8. Table D-9 V.35 Port Interface Connectors Signal CCITT Number Direction Pin Shield — — A Signal Common 102 — B Transmitted Data 10...
ACCULINK 316x DSU/CSU D-14 December 1996 3160-A2-GB22-10 Power Cable The power cable is a 14.5-foot, 18 AWG stranded cable. The connector is terminated at one end with a6-position Molex 39-01-2060 connector. The other end ofthe cable is terminated with a bare wire that should beconnected to a DC pow...
Pin Assignments D-15 3160-A2-GB22-10 December 1996 External Clock Connector The External Clock connector cable diagram is shown in Figure D-10. This is a customer-supplied cable.Connector pinouts are in Table D-11. Figure D-10. External Clock Connector Table D-11 External Clock Connector Signal Pin ...
ACCULINK 316x DSU/CSU D-16 December 1996 3160-A2-GB22-10 Slide Latch Adapter The Slide Latch Adapter 12-inch cable is shown in Figure D-11. The connector information is in Table D-12. Figure D-11. Slide Latch Adapter Cable (Feature Number 3100-F1-560) Table D-12 Slide Latch Connector Signal DA15P DA...
E-1 3160-A2-GB22-10 December 1996 SNMP MIB Objects Management Information Base (MIB) II (RFC 1213 ) E-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Group, MIB II E-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
ACCULINK 316x DSU/CSU E-2 December 1996 3160-A2-GB22-10 RS- 232-like MIB (RFC 1317) E-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Number of Ports – “rs2 32Number” Object (rs232 1) E-11 . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
SNMP MIB Objects E-3 3160-A2-GB22-10 December 1996 TransmissionGroup Supported on the T1 interfacesusing the DS1/E1 MIB. Supportedon the synchronous DCE data portsusing the RS-232-like MIB. Notsupported on the COM andMODEM ports. SNMP Group Supported. System Group, MIB II The System Group Objects ar...
ACCULINK 316x DSU/CSU E-4 December 1996 3160-A2-GB22-10 Interface Group, MIB II The interfaces group consists of an object indicating the number of interfaces supported by the unit and aninterface table containing an entry for each interface. TheT1 DSU/CSU provides an entry in the interface table fo...
SNMP MIB Objects E-5 3160-A2-GB22-10 December 1996 Interface Group – “ifAdminStatus” Object(ifEntry 7) This object specifies the desired state (configuration) of the interface. This object is supported only for theMODEM port. It provides the ability to switch betweenusing the MODEM port as the SNMP ...
ACCULINK 316x DSU/CSU E-6 December 1996 3160-A2-GB22-10 Interface Group – Output Counters (objects ifEntry 16 to ifEntry 21) The objects used to collect statistics on the data transmitted by an interface apply only to the COM portand the MODEM port when the port is configured as theSNMP management l...
ACCULINK 316x DSU/CSU E-8 December 1996 3160-A2-GB22-10 Near End Group – “dsx1SendCode” Object(dsx1ConfigEntry 7) This object specifies the test patterns/codes being sent over the Network T1 interface. These tests are notsupported on the DTE Drop/Insert T1 Interface. Only thefollowing values are sup...
SNMP MIB Objects E-9 3160-A2-GB22-10 December 1996 Near End Group –“dsx1TransmitClockSource” Object(dsx1ConfigEntry 12) This object specifies the timing source for the transmit clock for this T1 interface. This object differs from theMIB definition in that it is “read-only” (not read/write) forDSU/C...
ACCULINK 316x DSU/CSU E-14 December 1996 3160-A2-GB22-10 • testMonQRSS – Initiates a Monitor QRSS test onthe interface. Supported for the data ports and theNetwork T1 interface. • testMon511 – Initiates a Monitor 511 test on theinterface. Only supported for the data ports. • testSendQRSS – Initiates...
F-1 3160-A2-GB22-10 December 1996 Troubleshooting Table The ACCULINK 316x DSU/CSU is designed to provide you with many years of trouble-free service.However, Table F-1 gives you some direction if a problem occurs. For problems other than those listed inthe table, please contact your service represen...
G-1 3160-A2-GB22-10 December 1996 Configuration Worksheets This appendix contains one set of blank worksheets to be used when configuring your 316x DSU/CSU in thenetwork. It is recommended that you copy these blankworksheets before using them. G
H-1 3160-A2-GB22-10 December 1996 Equipment List Equipment Feature Number COMCODE PEC Code Model 3160 DSU/CSU in housing 3160-A2-211 107575367 2156-AS2 Model 3164 DSU/CSU in housing 3164-A2-211 107575391 2156-AS4 T1 Line Interface Cable, RJ48C-to-RJ48C, 20 feet 3100-F1-500 406941559 21587 Modular CO...
Glossary-1 3160-A2-GB22-10 December 1996 Glossary AIS Alarm Indication Signal. A signal transmitted instead of the normal signal tocontinue transmission continuity and to indicate to the receiving terminal that atransmission fault exists at either the transmitting terminal or upstream of thetransmit...
Index-1 3160-A2-GB22-10 December 1996 Index A abort loopback, 4-11test pattern, 4-14 alarm relay, 1-3, 4-2alarms, 4-2ASCII terminal, 1-2ASCII terminal/printer, 1-2, 2-14, 3-64, D-7async terminal, 3-70 menus, 2-17, 3-70, 3-71selection screens, 3-72terminating a session, 3-74 Auxiliary Backplane, 1-3,...
Paradyne Manuals
-
Paradyne 3160-A4
Manual
-
Paradyne 6700-A2-GB22-00
Manual
-
Paradyne 6310 MVLt
Manual
-
Paradyne MIM-2000F
Manual
-
Paradyne 3511 DSU
Manual
-
Paradyne 6301
Manual
-
Paradyne 3550
Manual
-
Paradyne 8546
Manual
-
Paradyne FrameSaver DSL
Manual
-
Paradyne Hotwire 7984
Manual
-
Paradyne 4000
Manual
-
Paradyne 3161 DSU
Manual
-
Paradyne Model 6039 MVL
Manual
-
Paradyne 8027
Manual
-
Paradyne 8540
Manual
-
Paradyne 9128-II
Manual
-
Paradyne 3163
Manual
-
Paradyne 8779
Manual
-
Paradyne 9783
Manual
- Paradyne 6211-I1 Manual