Page 2 - Software in whole or in part.
2 July 2005 IPD1-A2-GZ40-10 executed a separate written agreement covering the Software supplied to you under this purchase, such separate written agreement shall govern. Paradyne Corporation (“Paradyne”) grants to you, and you (“Licensee”) agree to accept a personal, non-transferable, non-exclusive...
Page 3 - regard to its provisions concerning conflicts of laws.; Introduction; – Rubber Bumper Screws
IPD1-A2-GZ40-10 July 2005 3 9. Upon such termination, the Licensee shall refrain from any further use of the Software and destroy the original and all copies of the Software in the possession of Licensee together with all documentation and related materials. 10. This Agreement shall be governed by t...
Page 4 - Installation Options; Installation on a Tabletop
4 July 2005 IPD1-A2-GZ40-10 If there is visible damage, do not attempt to connect the device. Contact your sales representative. Installation Options The 12000E BLC is designed for installation in a Restricted Access area where admittance is limited to trained and authorized service personel. It may...
Page 5 - Installing in a Rack; Procedure
IPD1-A2-GZ40-10 July 2005 5 Installing in a Rack Procedure 1. Using a Phillips screwdriver, attach the two provided rack mount brackets to the sides of the 12000E with eight of the ten provided bracket screws. There are seven position options for the rack brackets; position them as best suited to th...
Page 6 - Installing Your Management Module; Installing a Management Module
6 July 2005 IPD1-A2-GZ40-10 2. Mount the chassis onto the rack and secure the rack mount brackets to the sides of the rack using one of the two provided sets of eight rack screws (whichever size fits the rack being utilized). 3. Check the rack for stability, ensuring that installation of the 12000E ...
Page 8 - screws on the management module faceplate.
8 July 2005 IPD1-A2-GZ40-10 2. With the management module printed circuit board (PCB) facing right and the management module model name upright, align the upper and lower edges of the PCB with the slot module guides. 3. Slide the management module firmly into the chassis. Tighten the fastening screw...
Page 10 - on the interface module faceplate.
10 July 2005 IPD1-A2-GZ40-10 3. Slide the interface module firmly into the chassis. Tighten the fastening screws on the interface module faceplate. Fastening Screws
Page 11 - Do not operate the 12000E without a ground connection.
IPD1-A2-GZ40-10 July 2005 11 Powering Up Your 12000E CAUTION: Turn your DC power source(s) OFF until you have completed connection of the 12000E as outlined in the following sections. Do not operate the 12000E without a ground connection. Procedure 1. Connect a ground wire to the 12000E: Line up the...
Page 13 - Observe proper polarity.
IPD1-A2-GZ40-10 July 2005 13 4. Using a Phillips screwdriver, remove the left-hand screw from the chosen terminal block (labeled "+" on the chassis). Slide the ring terminal of your positive power lead around the shaft of the screw and insert the screw into the same "+" terminal from...
Page 14 - Establishing Your Uplink Connections
14 July 2005 IPD1-A2-GZ40-10 7. Verify the connection. Turn your power source(s) on. The PWR (power) LED on the interface module and management module faceplates will illuminate solid green to indicate the modules are receiving power. Establishing Your Uplink Connections No configuration is necessar...
Page 15 - Connecting Your Subscriber Lines
IPD1-A2-GZ40-10 July 2005 15 Connecting Your Subscriber Lines No configuration is necessary for the interface module(s) installed in your 12000E to operate at default settings. However, if you wish to run your subscriber connections at settings other than the defaults, configure the interface module...
Page 18 - Configuration and Management; Refer to the following documentation for further information:; Product Documentation Online; Complete documentation for Paradyne products is available at; Document
18 July 2005 IPD1-A2-GZ40-10 Configuration and Management Although no configuration is necessary to run subscriber lines at the default settings, all 12000E parameter settings are software selectable via Command Line Interface (CLI), Simple Network Management Protocol (SNMP), or the Network Manageme...
Page 20 - Specifications; Table 1. Specifications
20 July 2005 IPD1-A2-GZ40-10 Specifications Table 1. Specifications Specification Criteria Environment Operating Temperature: –40° F to 149° F (–40° C to 65° C) Storage Temperature: –40° F to 158° F (–40° C to 70° C) Humidity: 5 % to 95 %, non-condensing Altitude: –200 ft to 16,500 ft (–60 m to 5,00...
Page 21 - Important Safety Instructions
IPD1-A2-GZ40-10 July 2005 21 Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous high voltage points or oth...
Page 22 - CLASS 1 LASER PRODUCT:; UNITED STATES – EMI NOTICE:
22 July 2005 IPD1-A2-GZ40-10 12. In addition, if the equipment is to be used with telecommunications circuits, take the following precautions: — Never install telephone wiring during a lightning storm. — Never install telephone jacks in wet locations unless the jack is specifically designed for wet ...