Page 2 - Product Specifications; CCP FRIDGE·FREEZER; Contents
Important Safety Warnings page 2 Important Product Information page 3 Product Features page 3 LED Control Panel & Operation Instructions page 4-5 Bluetooth Mode Instructions page 6 Two Way Opening and Removable Lid page 7 Emergency Override page 8 Cleaning & Maintenance page 8 Troubleshootin...
Page 3 - Important Product Information
• Best performance is achieved in ambient temperatures between +10 °C and + 43 °C.• Temperatures above +32 °C may see a slight per- formance drop, and power consumption increase.• The lower the ambient temperature, the lower the power usage. In order to maximize effi ciency, keep the unit in a cool lo...
Page 4 - Single Zone; Changing the set temperature:; Dual Zone; Control Panel Single Zone; LED Control Panel & Operation Instructions
Turning the unit on and off: Step 1: Plug in the AC or DC power cable (ensure power is on at source).Step 2: Press the button once to turn on - To switch off press and hold the for 3 seconds. Changing the set temperature: Single Zone Step 1: Press the button once. Step 2: Use the and button to chang...
Page 5 - Setting Battery Protect:; Automatic shut down and re-start voltage levels:
Engaging Turbo mode: What is the purpose of Turbo Mode? It enables the compressor to run at a higher speed, therefore achieving faster cooling to your nominated temperature. Step 1: Press the button once to turn on. The light will illuminate green to indicate that Turbo Mode is engaged.Step 2: To tu...
Page 6 - What can I do through the app now; Bluetooth Mode Instructions
Activate Bluetooth mode: Step 1: Press the and button for 3 seconds together at the same time Step 2: Use the and button to choose either CLO (closed) or OPE (open). Step 3: Once you reach your desired setting you do not need to press any further buttons. Just leave it sit until you see the setting ...
Page 7 - Two Way Opening and Removable Lid; Purpose for removing the lid:; How to remove the lid:
CCP 30/36/44 CCP 60/69/73/85/96/105 CCP 60/69/73/85/96/105 CCP 60/69/73/85/96/105 WARNING: Potential pinch point. Never place fingers or items that can be damaged between the lid and the wall of the fridge as there is potential for injury page 7 Two Way Opening and Removable Lid CCP FRIDGE·FREEZER P...
Page 8 - The second DC socket; How to clean your unit:; Cleaning & Maintenance; Emergency Override; Fuse
The Emergency Override Switch is located just below the main control panel next to the power inlets For normal operation the switch is in the “NORMAL USE” position. If the electronics in the display board fail or controls become non-functional, slide the switch to EMERGENCY OVERRIDE position. NOTE: ...
Page 9 - How to get the most out of your unit:; The unit is not turning on; Unusual noise when refrigerator is working; Troubleshooting
How to get the most out of your unit: • Best performance is achieved at ambient temperatures between +10 °C and +32 °C.• Product is rated as a ‘T Climate’ class (Tropical), which means that the units meet the requirements of ISO -15502 at 43 °C.• Higher ambient temperatures mean that the compressor ...
Page 10 - E0 flash every 4 seconds temperature sensor issue:; flashes every 4 seconds - compressor start issue:; flashes every 4 seconds - low motor speed:; flashes every 4 seconds - over temperature:; Status Indicator
E0 flash every 4 seconds temperature sensor issue: • Contact Leisure-Tec on 1300 07 2018 E1 flash every 4 seconds - low voltage & Battery Protection: • An E1 will occur when the battery protection level has been reached. i.e input voltage to low for protection setting, check power source voltage...
Page 12 - Warranty Terms & Conditions
LEISURE-TEC Australia Pty Ltd50 Metrolink Circuit Campbellfi eld, VIC 3061 Australia 1300 07 2018 Model CCP 30 Single Zone CCP 36 Single Zone CCP 44 Single Zone CCP 60 Single Zone CCP 73 Single Zone CCP 105 Single Zone CCP 69 Dual Zone CCP 85 Dual Zone CCP 96 Dual Zone Dimensions mm Length 610 Width...