Summary

Page 6 - Uninstalling IM-2G Modules

5 STEP 2 : Mounting the EDS-728/828 on the wall requires 4 screws to ensure that the switch does not come loose from the wall. Use the switch, with wall mounting plates attached, as a guide to mark the correct locations of the 4 screws. The heads of the screws should be less than 6.0 mm in diameter,...

Page 7 - Wiring Requirements; Grounding Moxa EtherDevice Switch; Wiring the Relay Contact

6 Wiring Requirements WARNING Safety First! Be sure to disconnect the power cord before installing and/or wiring your Moxa EDS-728/828. Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size. ...

Page 8 - Wiring the Redundant Power Inputs

7 RELAY1 RELAY2 PWR1 PWR2 V2+ V2- V1+ V1- D I 1 I 1 I 2 D I 2 Top View Front View FAULT : The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-configured events. The two wires attached to the Fault contacts form an open circuit when a user-configured event is ...