Page 3 - encourage proper operation and maintenance.; NTENDED; SVTR
3 2 C AUTIONARY I NFORMATION 1. Read these instructions entirely before beginning any part of the installation. Save these instructions for any future repairs. 2. Use these instructions as a guide during the installation of the fireplace. 3. Be sure these instructions become the property of and are ...
Page 6 - LEARANCES
6 C LEARANCES F IGURE 3 ( ALL DIMENSIONS IN INCHES .) NOTE: DIMENSIONS MAY VARY SLIGHTLY DUE TO MANUFACTURING TOLERENCES. NOTE: DIMENSIONS MAY VARY SLIGHTLY DUE TO MANUFACTURING TOLERENCES. 4 5/16 16 1/16 9 13/16 25 9/16 12 3/16 30 3/4 21 13/16 46 3/8 27 13/16 56 3/4 30 5/16 61 1/16 SE30ELBOW S12 S1...
Page 7 - CAUTION: Do not install fireplace over carpeting.; FULL PROJECTION
7 F IREPLACE L OCATION CAUTION: Do not install fireplace over carpeting. This fireplace does not weigh more than large pieces of furniture and can normally be located near a loadbearing wall without requiring additional foundations or supports. If however, the fireplace is to be trimmedwith a heavy ...
Page 9 - MULTIPLE STORY INSTALLATION; NSTALLATION
9 INSTALLATION HEIGHT STORM COLLAR(INCLUDED WITH CAP) (612 OR 1212) FLASHING SF FIRESTOP SPACER(1 3/4" AIR SPACECLEARENCE TO COMBUSTIBLES) 2" MIN. CLEARENCE TO COMBUSTIBLES 14 1/2" SQUARE OPENING IN JOIST FLASHING (612 OR 1212) SEE TABLE 1 FOR ROOF OPENING SIZE SC CHIMNEY CAP SINGLE STOR...
Page 11 - METAL SAFETY STRIP
11 16" (MIN) METALSAFETYSTRIP 52" (MIN) The ability of insulating material to retard the transfer of heat may be expressed as either Thermal Conduc-tance (C), Thermal Conductivity (K), or Thermal Resistance (R). The mathematical relationship of thesevalues and the formulas for converting one...
Page 13 - SEE FIGURE 13 FOR ILLUSTRATION OF MODELS DESCRIBED BELOW.
13 F IREPLACE C OMPONENTS SEE FIGURE 13 FOR ILLUSTRATION OF MODELS DESCRIBED BELOW. 53D9033. Rev 1 03/03 * * 48" x 84" flat chase flashing with single 11" diameter hole. 16-inch x 52-inch Hearth extension for protecting floor against sparks and radiant heat. 4-inch duct connector for spl...
Page 15 - Nail the support straps tightly to a
15 C HIMNEY I NSTALLATION 1. Lay out, cut and frame openings through all ceilings and the roof at the point where the chimney will pass through. Unless the chimney is to be offset, the point where the center line of the chimney will passthrough the ceiling and roof can be determined with a plumb lin...
Page 17 - LBOW; and elbows required from the offset chart. Refer to Table 2.
17 30∞ ELBOW 8-PENNY NAILS PER STRAP. AROUND THE ELBOW WITH TO FRAMING MEMBER A MINIMUM OF TWO (2) STRAPS MUST BE NAILED ALL FOUR SUPPORT FLUE PIPE INLET AIR PIPE SURROUNDING STRUCTURE. BE NAILED SECURELY TO THE ON TOP OF THE FIREPLACE SHOULD ELBOWS NOT INSTALLED DIRECTLY THE SUPPORT STRAPS OF ALL C...
Page 18 - SF30 FIRESTOP SPACER; HIMNEY
18 CONTINUE CHIMNEY TO PROPER CONTINUE CHIMNEY TO PROPERHEIGHT AND INSTALL ROUND HEIGHT AND INSTALL ROUNDCHIMNEY CAP OR CHIMNEY CHIMNEY CAP OR CHIMNEYHOUSING. HOUSING. FASTEN SUPPORT STRAPS SECURELY FASTEN SUPPORT STRAPS SECURELY ROOF ROOF FLASHING FLASHING STORM COLLAR STORM COLLAR NOTE: TWO ELBOWS...
Page 19 - ODEL; SC C; the flashing under the shingles.
19 C HIMNEY C AP I NSTALLATION M ODEL SC C HIMNEY C AP S PECIAL N OTE : The proper height as previously explained is important to assure proper draft and safety. The chimney cap extends the flue outlet four inches above the top of the last section of chimney. This should bekept in mind when determin...
Page 21 - metal chimney components.; installation and that all parts have been installed properly.
21 C HIMNEY C AP C HASE I NSTALLATION The preinstalled chimney sections should be no more than 10 inches below the top of the chase. The installationshould be planned so that either an 18-inch or 36-inch chimney section will be used for the top section. Thisis necessary to ensure complete engagement...
Page 22 - INSTALLATION OF; CONNECTING OUTSIDE AIR STARTING COLLAR AND AIR DUCT TO FIREPLACE
22 O UTSIDE C OMBUSTION A IR P RECAUTIONS & R ECOMMENDATIONS NOTICE: Outside air for combustion is optional in residential type installations unless required bylocal codes; it is mandatory in manufactured home installations. An AK4 outside combustion air kit isoffered for use in residential type...
Page 23 - fumes such as gasoline might be drawn into the fireplace.
23 O UTSIDE C OMBUSTION A IR P RECAUTIONS & R ECOMMENDATIONS 1. Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly should be avoided. These conditions will increase the resistance to the free flow of air throughthe duct. See Figure 27 for...
Page 24 - OR; right side of the fireplace. DO
24 C OMBUSTION A IR A SSEMBLY T O I NSTALL T HE O UTSIDE C OMBUSTION A IR K IT 1. Remove the cover plate from the outside air opening located on the left OR right side of the fireplace. DO NOT remove the cover plate if the outside air will not be connected. 2. Insert the outside air starting collar ...
Page 25 - position at all times.; local code authorities before proceeding with the installation.; DANGER: Do not use candles, matches or other ignition sources
25 G AS A PPLIANCE I NSTALLATION Fireplaces, ANSI Z21.60. If a decorative gas appliance is installed, it must be installed in accordance withthe National Fuel Gas Code, ANSI Z223.1. C AUTION : When a decorative gas appliance is installed, the fireplace damper must be set in the fully open position a...
Page 26 - GAS LINE PLUMBING; Seal the face of the fireplace to the surrounding wall with non-; RIM
26 G AS A PPLIANCE I NSTALLATION OPEN POSITION. BACK REFRACTORY BRICK SIDE REFRACTORY BRICK SIDE BRICK INNER FIREPLACE WRAP OUTER FIREPLACE WRAP COMBUSTIBLE MATERIALS MAY BE LOCATED AT ZERO CLEARANCE TO GAS LINE BEYOND 4" FROM FIREPLACE SIDE. MAINTAIN 1/2" MINIMUM AIR SPACE CLEARENCETO COMBU...
Page 28 - LASS; The SWB400I fireplace may be equipped with an FA2 fan; IF; the fireplace is also equipped with optional
28 BLACK TO FUSE OR 120V, 60HZ CORDSET GROUND WHITE CIRCIUT BREAKER FAN 1 FAN 2 SPST SWITCH FA2 FAN JB1 JUNCTION BOX ON SIDE OF FIREPLACE NOTE: THE JBI JUNCTION BOX SHOULD BE INSTALLED AND ITS RECEPTACLE WIRED TO THE ELECTRICAL SYSTEM OF THE DWELLING DURING INSTALLATION OF THE FIREPLACE ON WHICH THE...
Page 30 - or other improper fuels.
30 F IREPLACE O PERATION A F EW W ORDS OF C AUTION Beware of burning certain material in your fireplace. Among these are plastics, poison ivy twigs and stems,and chemically treated woods such as discarded poles and railroad ties. These not only create air pollution,but can induce extreme irritation ...
Page 32 - DO’S; prevent contact with and possible damage to the chimney.; AINTENANCE
32 F IREPLACE M AINTENANCE At the end of each heating season or when the fireplace will not be in use for an extended time, the ashes should beremoved and the hearth area should be swept as clean as is practical. The slow absorption of moisture into theashes over a long period of time could cause a ...
Page 33 - DON’TS
33 20. Do build fires of moderate intensity in the fireplace for the first three fires to allow materials to adjust and cure before being subjected to the intense heat of a large fire. DON’TS 1. Don’t allow other installations or operation considerations to take priority over safety considerations.2...
Page 34 - WELDMENT AIR DOOR ROD; ARTS; Technical Service Department
34 PART NUMBER 069726020293076694 077558 049418047619078117078355077557 PART NAME UPPER PANEL PNTD. ASSY. WELDMENT AIR DOOR ROD FIRESCREEN PANELFIREBRICK BACK ASSY.FIREBRICK LEFT SIDE LOWER PANEL PNTD. ASSY.GRATE PNTD. ASSY.HEARTH REFRACTORY ASSY.HEARTH FRONT LEDGE 077559 KEY NO. 1 23456789 QTY. 12 ...
Page 36 - FACTORY-BUILT FIREPLACE AND COMPONENTS; EXCEPT; This limited warranty does not cover:; Monessen Hearth Systems
36 L IMITED W ARRANTY FACTORY-BUILT FIREPLACE AND COMPONENTS ( EXCEPT BLOWERS ) W HAT IS COVERED AND FOR HOW LONG • F IVE -Y EAR C OVERAGE - For five years from the date this fireplace and components are first purchased for use, Monessen Hearth Systems will, at its option, repair or replace any defe...
Page 37 - IMITED
37 Y OUR D UTIES This fireplace must be installed by a qualified installer according to your local building codes and installation instructionsand operated according to the owner’s instructions. You must keep an invoice, canceled check or payment record to verifythe purchase date of the fireplace. I...