Page 2 - BBV, SBV Series Natural Vent Gas Fireplaces; TABLE OF CONTENTS; Pre-Installation Information
62D4036 2 BBV, SBV Series Natural Vent Gas Fireplaces TABLE OF CONTENTS Thank you and congratulations on your purchase of an MHSC Fireplace Please read the Installation and Operation Instructions before using the appliance! IMPORTANT: Read all instructions and warnings carefully before starting inst...
Page 3 - IMPORTANT SAFETY INFORMATION; CARBON MONOXIDE POISONING:; Cleaning and Mainte-; Any change to this fireplace or its controls can be dangerous.; ARNING
62D4036 3 BBV, SBV Series Natural Vent Gas Fireplaces IMPORTANT SAFETY INFORMATION INSTALLER Please leave these instructions with the appliance. OWNER Please retain these instructions for future reference. This fireplace is a decorative gas appliance. This fire-place must be properly installed by a ...
Page 4 - CODE APPROVAL; LISTED VENTED GAS FIREPLACE; Canadian Electrical; For Massachusetts Residents Only:; PLEASE READ THE FOLLOWING CAREFULLY; California Health and Safety Code Sec. 25249.6
62D4036 4 BBV, SBV Series Natural Vent Gas Fireplaces CODE APPROVAL These appliances have been tested by CSA and found to comply with the established standards for VENTED GAS FIREPACES in the US and Canada as follows: LISTED VENTED GAS FIREPLACE TESTED TO: ANSI Z21.50a-2008 CSA2.22a-2008 14. Do not ...
Page 6 - FIREPLACE DIMENSIONS & FRAMING; FIREPLACE FRAMING; Figures 2 or 3
62D4036 6 BBV, SBV Series Natural Vent Gas Fireplaces FIREPLACE DIMENSIONS & FRAMING Do not fill spaces around firebox with insulation or other materials. This could cause a fire. W ARNING 31 6 ” (797 mm) 8” (203 mm) 14” (356 mm) 14 56O ” (368 mm) Min. Rough OpeningDepth 40 56O ” (1029 mm) Min. ...
Page 7 - Framing Dimensions; NOTE
62D4036 7 BBV, SBV Series Natural Vent Gas Fireplaces FIREPLACE DIMENSIONS & FRAMING 21” (533 mm) 21 56O ” (546 mm) Min. Rough OpeningDepth 4” B-Vent 1/2” or 5/8”Drywall Spacers 40" (1016 mm) 34” (864 mm) 21 56O ” (546 mm) B A 40 56O ” (1029 mm) Min. RoughOpening Height 1/2" or 5/8" ...
Page 8 - PRE-INSTALLATION INFORMATION; Never obstruct the front opening of the fireplace.; CLEARANCES TO COMBUSTIBLES
62D4036 8 BBV, SBV Series Natural Vent Gas Fireplaces FP2406BBV 400 clearances PRE-INSTALLATION INFORMATION FIREPLACE LOCATION Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, a...
Page 9 - SECURE FIREPLACE TO FLOOR OR FRAMING; Figure 5; FINISHING MATERIAL
62D4036 9 BBV, SBV Series Natural Vent Gas Fireplaces SECURE FIREPLACE TO FLOOR OR FRAMING The fireplace must be secured to the floor and/or to framing studs as shown in Figure 5 . Use two (2) wood screws or masonry/con-crete screws to secure fireplace to the floor. Use four (4) screws to attach fir...
Page 10 - VENT INSTALLATION; “B” VENT PIPE; Pages; Attaching 4” Flue to BBV:
62D4036 10 BBV, SBV Series Natural Vent Gas Fireplaces VENT INSTALLATION INSTALLATION PLANNING “B” VENT PIPE See venting installation instructions provided by the B-Vent manufacturer. NOTE: This APPLIANCE MUST BE INSTALLED using “B” vent type pipe that has been listed by a nationally rec-ognized tes...
Page 11 - TERMINATE THE PIPE; Termination Height Table
62D4036 11 BBV, SBV Series Natural Vent Gas Fireplaces VENT INSTALLATION FIRESTOPS • Locate chimney centerline dimension from a com- bustible back wall. Figures 2 & 3. Minimum firestop dimensions are found in the vent manufacturer’s in-structions. Clearances to combustibles may also be found on ...
Page 12 - OUTSIDE COMBUSTION AIR; Figure 9
62D4036 12 BBV, SBV Series Natural Vent Gas Fireplaces OUTSIDE COMBUSTION AIR NOTE: The use of outside air for combus- tion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of fireplace. Use model OAC4 combustion air kit (refer to Page ...
Page 13 - COMBUSTION AIR ASSEMBLY
62D4036 13 BBV, SBV Series Natural Vent Gas Fireplaces COMBUSTION AIR ASSEMBLY MODEL OAC-4 COMBUSTION AIR ASSEM-BLY 1. Remove the cover plate from the 4” outlet opening location on the left outside of the fireplace. 2. Place starting collar (4”) into hole on left side of fire- place. Fireplace short...
Page 14 - FIREPLACE INSTALLATION; INSTALLATION ITEMS NEEDED
62D4036 14 BBV, SBV Series Natural Vent Gas Fireplaces FIREPLACE INSTALLATION CHECK GAS TYPE Use proper gas type for the fireplace you are installing. If you have conflicting gas types, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type. INS...
Page 16 - CHECKING GAS PRESSURE; the gas supply is different from the fireplace,
62D4036 16 BBV, SBV Series Natural Vent Gas Fireplaces CHECKING GAS PRESSURE 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately. 2. To eas...
Page 17 - ELECTRICAL INSTALLATION; Verify proper operation after servicing.; REMOTE WALL MOUNTED SWITCH; Do not extend beyond
62D4036 17 BBV, SBV Series Natural Vent Gas Fireplaces ELECTRICAL INSTALLATION Verify proper operation after servicing. REMOTE WALL MOUNTED SWITCH A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired ...
Page 18 - Position the wall switch. Do not extend beyond the 15’ of wire.; OPTIONAL DC REMOTE SYSTEMS
62D4036 18 BBV, SBV Series Natural Vent Gas Fireplaces ELECTRICAL INSTALLATION ELECTRONIC PILOT IGNITION WIRING W ARNING Do not connect 110-120V AC to the Re-mote Wall Switch. The appliance will malfunction or destroyed. &0ELECTRONICIGNITIONWIRING Figure 17 - Electronic Ignition System Wiring Di...
Page 19 - FINAL INSTALLATION; Place rock wool on burner to provide glowing
62D4036 19 BBV, SBV Series Natural Vent Gas Fireplaces LG662BBV SBV400 logs FINAL INSTALLATION ROCK WOOL PLACEMENT 1. Place rock wool on burner to provide glowing embers. For best results, pull the rock wool apart into pieces the size of a nickel or dime. 2. Distribute one layer of rock wool to cove...
Page 20 - OPERATING INSTRUCTIONS; FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS:; LIGHTING PILOT FOR THE FIRST TIME; INITIAL LIGHTING
62D4036 20 BBV, SBV Series Natural Vent Gas Fireplaces OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal in-jury or loss of life. A. This appliance is equipped with a ...
Page 22 - LIGHTING BURNER; MAIN BURNER SWITCH; Depress and turn the knob counterclockwise; PILOT POSITION; Depress and turn knob clockwise
62D4036 22 BBV, SBV Series Natural Vent Gas Fireplaces OPERATING INSTRUCTIONS LIGHTING BURNER LIGHTING PILOT T O L I P O F F P IL O T ON &0CONTROLKNOBPILOT Figure 23 - Pilot Position MAIN BURNER SWITCH The “ON/OFF” switch for the main burner can be found behind the door of the fireplace. This sw...
Page 23 - LIGHTING ELECTRONIC IGN; What to Do if You; TO TURN OFF GAS
62D4036 23 BBV, SBV Series Natural Vent Gas Fireplaces OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal in-jury or loss of life. A. This appliance is equipped with an...
Page 24 - CLEANING and MAINTENANCE; The pilot flame has; BURNER
62D4036 24 BBV, SBV Series Natural Vent Gas Fireplaces LG663BBV SBV400 log flame LG663 CLEANING and MAINTENANCE W ARNING Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. BURNER, PILOT AND C...
Page 25 - Final; ROCK WOOL; Final Installation
62D4036 25 BBV, SBV Series Natural Vent Gas Fireplaces CLEANING and MAINTENANCE VENT SYSTEM The fireplace and venting system should be inspected before initial use and at least annually by a quali-fied field service person. Inspect the external vent cap on a regular basis to make sure that no debris...
Page 26 - REPLACEMENT PARTS
62D4036 26 BBV, SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS FIREBOX COMPONENTS 4a 4b 4c ""63"6FIREBOXPARTS 1 2 3 5 6 7
Page 27 - LOGS; Item Description
62D4036 27 BBV, SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS FIREBOX COMPONENTS Item Description Qty. BBV400 SBV400 SBV500 1. Pull Screen Panel 2 61D0001 61D0001 61D0003 2. Refractory Side 2 n/a 61D0101 61D0101 3. Refractory Back 1 n/a 61D0102 61D0102 4a. Left Refractory 1 n/a 62D1015 62...
Page 29 - LP to Natural Gas
62D4036 29 BBV, SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS STANDING PILOT - MILLIVOLT CONTROL Item Description Qty. BBV400NV BBV400PV SBV400NV SBV400PV SBV500NV SBV500PV 1. Gas Valve Assembly 1 37D0117 37D0118 37D0117 37D0118 37D0117 37D0118 2. Pilot Assembly 1 37D0018 37D0019 37D0018 ...
Page 32 - TROUBLESHOOTING; SYMPTOM
62D4036 32 BBV, SBV Series Natural Vent Gas Fireplaces TROUBLESHOOTING STANDING PILOT IGNITION SYMPTOM 1. Spark igniter will not light pi-lot after repeat-ed triggering of piezo. 2. Pilot will not stay lit after carefully fol-lowing lighting instructions. 3. Pilot burning, valve knob tuned to “ON”, ...
Page 38 - NOTE REGARDING VENTED PRODUCTS
62D4036 38 BBV, SBV Series Natural Vent Gas Fireplaces NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.Any residence with a direct vent product must have a CO detector installed in the residence...
Page 39 - LIMITED LIFETIME WARRANTY POLICY; LIFETIME WARRANTY; DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF.
62D4036 39 BBV, SBV Series Natural Vent Gas Fireplaces LIMITED LIFETIME WARRANTY POLICY LIFETIME WARRANTY The following components are warranted for life to the original owner, subject to proof of purchase; Firebox, Combus-tion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. FIVE YEAR WA...
Page 40 - MHSC
MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com