Stop Operation CC - This type is integral with casting, actuated by screwdriver, and require a 90 ° turn to open or close. When the screwdriver slot is vertical, the rubber stop is closed, and when the slot is horizontal, the rubber stop is open. IPS - This type has been added to the basic shower ca...
Disassembly Turn "OFF" both hot and cold water supplies, then open faucet to relieve pressure. Remove handle cover from handle knob. Take out handle screw andremove handle knob, washer, and stop tube. Lift out retainer clip. Rotate cartridge shell back and forth with Moen cartridge twist wre...
25300 Al Moen Dr., North Olmsted, OH 44070-8022 U..S.A. HELPLINE: Call our toll free Helpline number, for answers to any product, installation, replacementparts, or warranty questions. MT620J AUG '96 To Eliminate Cross-Piping On Back-To-Back Installations or To Correct Reversed Rough-In Where Hot an...