Summary
In this manual, Microsoft® Windows® 8.1 Pro is called Windows 8.1, Microsoft® Windows® 7 Professional is Called Windows 7, and Microsoft® Windows Vista® Business is Called Windows Vista. In this manual, Microsoft® Excel 2013/2010/2007 is called Excel. Trademarks MS, Microsoft, Microsoft logo, and Wi...
"HWHP (CAHV)” : Refers to HWHP main (CEH) and HWHP sub (CL) that can be connected to AG-150A/GB-50ADA Ver.2.90 or later and AE-200/AE-50. EB-50 and G-50A cannot be connected. "Advanced HVAC CONTROLLER”: Refers to Advanced HVAC CONTROLLER (AHC) that can be connected to AE-200/AE-50/EB-50....
1 • Please read the Safety Precautions section very carefully before using the unit.• The safety cautions provided here are very important for your safety. Please observe them at all times.• The degree of danger involved with incorrect operation of the unit are indicated in this manual using the fol...
2 Safety Guidelines for the Computer Running with the TG-2000A. (1) Precautions for selecting a computer (2) Precautions for General usage (3) Other precautions Safety Guideline for LAN connection of the centralized controller Select a desktop computer. • Depending on the function, it is recommended...
3 This integrated centralized control software TG-2000A is used to monitor/operate an air conditioner group with multiple centralized controllers connected. The instruction manual for this integrated centralized control software TG-2000A consists of Site adjustment, Management (this manual), and Wid...
4 2.2 Preoperation Check List (1) Installation conditions check Check the wiring, connection, initial settings etc of the computer and peripheral devices. Verify that each device is installed in accordance with its installation and instruction manuals. (2) Site adjustment check Before using the syst...
5 2.3 Items to Check before Starting Operation (1) About the Windows (Reboot function) Be sure to set the Reboot settings. Reboot the PC periodically both manually and automatically. Refer to Section 8.3.2 Reliability Function in the Operation manual (Site adjustment) for how to set the Reboot set...
6 3.1 Screen Configuration The Management screen consists of the following parts: Item Details Group icon Display the state of the air conditioner or etc., and operates On/Off. Function select buttons Select the function. Display units buttons Select the display unit for each function. Floor switchi...
7 3.2 Operations Mouse operation The following description assumes that a mouse is used as the pointing device. When using another pointing device, read the description for that device. Operation on the screen is the same. The keyboard can also be used to input characters and numbers. Move the mouse...
9 The function is selected with the function select buttons (top left-hand side of screen) and the operation object is displayed on the display & operation screen with the display units buttons (top right of screen). 4.1 Function Select Buttons and Display Units Buttons This table shows which fu...
10 4.2 Display Units Buttons Operation The methods of operating the air-conditioners in group units, block units and for the whole building, and the methods of operating the general equipment in group units and in batch units are explained in this section. (1) Floor screen On the floor screen, the a...
11 (2) Block screen The air-conditioners can be operated and monitored in block units using the Block screen. (3) Whole building screen The air-conditioners for the whole building can be operated and monitored using the Whole building screen. (4) System equipment screen The units other than the indo...
12 4.3 Display method for Site change display The following is the display method for “Site change” display of wide area mode. Use menu bar [Tool]-[Site change tool] to display “Site change” display. 4.4 Display method for Mail display The following is the display method for “Mail” display when usin...
13 4.5 Startup and Shutdown Start the TG-2000A application. [Procedure] 1) Restart Windows When Windows (OS) restarts, the user automatically logs on and the TG-2000A program starts. * TG-2000A can also be started by selecting “TG2000” in the Windows Start Menu. TG-2000A Shutdown [Procedure] 1) Sele...
14 The items to be set or checked at the operation start-up are shown in this chapter. Set the functions being used. 5.1 Schedule Setting For a description of the schedule setting method, refer to chapter 7. Schedule Setting. 5.2 Air-conditioning Charge Setting When the [Energy monitoring] button in...
15 [Using the RS-485 WHM] Set the Currency unit [Procedure] 1) Click the [Currency unit] button. Click the [Currency unit] button in the Charge Set screen. The currency unit set screen opens. This screen is also displayed when the currency Set screen is opened. 2) Select the currency unit to be used...
16 Set the settlement date Since the air-conditioning charge is calculated once a month, set the settlement date. [Procedure] 1) Click [Settlement date designation] button. When the [Settlement-date designation] button at the screen is clicked, the Settlement-date designation setting screen opens. 2...
17 [Using PLC WHM or PI controller WHM, and without WHM connection] Set the Currency unit [Procedure] 1) Click the currency unit [Change] button. Select the currency unit [Change] button on the Charge Set screen to open the Currency Unit screen. 2) Set the currency unit. Select the currency unit fro...
18 Weekly charge set-up Set the weekly charge unit and each day's time zone for normal operation and season operation. If the seasonal period is not set, the "Usual charges" and "Seasonal charges" can be selected. [Procedure] 1) Select the weekly charge [Change] button. Select the we...
19 Set the settlement date Since the air-conditioning charge is calculated once a month, set the settlement date. [Procedure] 1) Click [Settlement-date designation] button. When the [Settlement-date designation] button at the bottom right-hand side of the screen is clicked, the Settlement-date desig...
20 6.1 Monitor/Operation Perform normal operation from the Management screen. Display the Management screen by clicking the [Monitor/Operation] function select button (top left-hand side of screen), then selecting the operation object from the display units buttons (top right-hand side of screen). T...
23 Explanation of group icons ( instrumental equipment ) [Icon color] Gray:Normal, Orange:Error Operation status [Thermometer/normal] [Hygrometer/normal] [Thermometer/detection limit] [Hygrometer/detection limit] Error status [Thermometer abnormal] [Hygrometer abnormal] *1:Temperature value and humi...
25 (3) Block screen The details displayed on the Block screen are explained below. (4) Whole building display screen The details displayed on the Whole building display screen are explained below. [Air-conditioner group, General equipment (DIDO) group display] (Including Air To Water (PWFY)) (Green)...
26 6.4 Operation Details Air conditioner operation mode switching, temperature adjustment, and other functions can be monitored and operated. Objects which can be monitored and operated: Floor, block, whole building (1) Display the remote control screen. [Procedure] 1) Select the operation setting. ...
27 Item Details Object name Group : Display the group name (Full). Floor (batch) : Display the floor name. Block : Display the block name. Whole buildings : Display whole buildings. General equipment : Display the general equipment name (Full). On/Off button Display the current On/Off state. (The st...
30 When Fahrenheit is chosen by Centralized controller 6.5 Other Functions The following are displayed on Floor screen of the monitor/operation screen: Full name Block name (Operation block name) Charge block name Energy saving / Peak cut control information [Procedure] 1) Select group. When...
32 The operation mode, temperature, wind velocity, and On/off from the specified time can be set with the schedule setting function. To set a schedule, “On (start)” or “Off (stop)” must always be selected. Today’s schedule, weekly schedule or annual schedule can be set. A schedule for each day can b...
34 7.1 Today’s Schedule Setting 1) Select the today’s schedule. When the today’s schedule is clicked on in the menu, the today’s schedule set screen opens. The information saved in the integrated centralized control software TG-2000A appears on the screen. Perform the following operations from the t...
35 For AE-200/AE-50/EB-50/AG-150A/GB-50ADA only (The setting is not displayed for G-50A) Click the “ ▲ / ▼ ” buttons to make Air direction setting. Click the “ ▲ / ▼ ” buttons to make Fan speed setting. To delete a set schedule, click the [Delete] key. General equipment schedule details setting scre...
36 6) Click the [OK] button after making the settings. The set schedule appears on the current day schedule set screen. * The set details are invalidated when the [Cancel] button is clicked on. (2) Schedule change Use this function to change a set schedule. [Procedure] 1) Select the current day sche...
38 7.2 Weekly Schedule Setting Seasonal settings can be set on Weekly Schedule with AE-200/AE-50/EB-50/AG-150A/GB-50ADA. Up to two types of settings can be set for Seasonal setting. Refer to (1) Seasonal settings for the setting method. *The “Weekly 1” (except the “Seasonal settings”) function is av...
39 2) Set the seasonal settings Set the each duration of Weekly1 through Weekly5 when the settings are divided into five seasons. Seasonal settings can be enabled or disabled for each of the weekly settings between 2 and 5. To set the beginning and the ending date of the operating season, check the ...
40 (2) Schedule setting [Procedure] 1) Select the pattern data. Select from the pattern data selection box [AG-150A/G-50A Data], [Summer Master], [Winter Master], [Schedule Master 1] [Schedule Master 2], or [Schedule Master 3] When [Summer Master], [Winter Master], [Schedule Master 1], [Schedule Mas...
43 3) Press the [OK] button after confirming or changing the settings. The changes are saved and the weekly schedule set screen opens. * The set details are invalidated when the [Cancel] button is clicked on. Ending weekly schedule setting Select [Send] or [Cancel] button. At the end of schedule set...
44 7.3 Annual Schedule Setting With the annual schedule, up to 50 days (including that day) in the next 24 months (including current month) can be set for each air conditioner group. This is handy for sending a schedule that does not fit into the weekly schedule, such as holidays and summer vacation...
47 (5) Checking the pattern details [Procedure] 1) Select the Pattern button. The menu opens when the Pattern button is clicked on. 2) Select [View]. Click the menu [View]. The details screen opens. The details for “Time”, “On/Off”, “Mode”, “Temperature Setting”, “Ventilation mode”, “Remote Controll...
48 (7) Annual schedule clearing [Procedure] 1) Select the date for which a schedule is set. A menu appears. 2) Select [Clear Schedule Setting]. Click the menu [Clear Schedule Setting]. The pattern assignment set for that date is cleared. * All dates set in the schedule can be canceled by clicking th...
50 Schedule details display [Procedure] 1) Select the day or date button. The detailed view opens when the day or date button is clicked on the Schedule view display screen. 2) Select the [Cancel] button. * Side scrolling on the screen displays setting items for Air direction and Fan speed when AE-2...
51 7.5 Schedule Copy The details set for the schedule can be copied in group units. Select the copy target from the today’s schedule, weekly schedule, annual schedule or weekly & annual schedule. Copying schedules between groups [Procedure] 1) Click the copy from group When the cursor is set to ...
52 8.1 Abnormality History and Operation History There are two kinds of history: Abnormality history and Operation history. Item Details Abnormality history Display errors currently occurring and that occurred in the past. * Click the [History Update] button to display the latest abnormality history...
54 (3) History screen operation The Abnormality History and Operation History screen displays can be switched and updated. [Procedure] History display switching When the [Abnormality history] button is clicked, the display switches to the Abnormality History screen and when the [Operation history] b...
56 (6) History output Output daily or monthly history. The output is only compatible with the file output (CSV format). (Search results history cannot be output.) [Procedure] 1) Select [Daily] or [Monthly] button. When the [Daily] or [Monthly] button is clicked, the Output History screen opens. 2) I...
64 8.4 Operation Time Display The air-conditioner operation time is counted in a group unit and displayed. (1) Switching from Monitor/Operation screen to Operation time screen [Procedure] 1) Select the [Operation Time] button. The Operation time screen opens when the [Operation Time] button is click...
65 8.5 Abnormality Occurrence 8.5.1 Abnormality Display It is possible to confirm the state of errors occurring on the Management screen at the lower part on the group icon or the monitor/operation screen, and on the screen of floor, block, whole buildings, and system equipment. (1) Display when abn...
66 There is a “Unit normal/abnormal” display on the monitor/operation screen. “Normal” or “Abnormal” blinks on the screen. Unit type Error display conditions AG-150A/G-50A Centralized controller or Expansion controller error (incl. communication error) has occurred. * While the centralized controlle...
69 (3) Message: "This comment is the result of comparing of maintenance information and real system information. Please check if needed." Setting conditions: Always under the following conditions. 1) When TG-2000A is started up. 2) When the setting details are sent to Centralized controller ...
70 Remarks: If the details set in the integrated centralized control software TG-2000A and the actual operation match, send the settings on the initial setting screen, and then check. The warning display screen will close when the "OK" button on this screen is pressed. Operations and monitor...
73 (Continued from previous page) Mismatch (Code) Mismatch Remedy [6] [3] Message Code1 [7] [8] [1] Different point (1) [2] Different point (2) Code2 Code3 [4],[5] Item 4 Energy-saving information has a difference. Refer to the previous table. 3 1 AG-150A(EC)/G-50A No. Address There are discrepancie...
77 8.6 Meter Status Monitor The meter integrated value monitor and monitor abnormal/normal status can be checked. Meter integrated value monitoring method [Procedure] 1) Select [Monitor/Operation]. When the [Monitor/Operation] button of the function selection buttons is selected, the monitor/operati...
78 8.7 Trend Data Output If the trend function is valid, the set temperature, intake temperature, WHM and apportioned electric amount trend data can be output in the CSV format. Outputting the trend data [Procedure] 1) Select [Trend] from the [Tool] menu. Select [Tool] and [Trend] from the Managemen...
79 3) Select the various items. Select or set the target to be output, the date (term), file export destination and file name. The trend data output of Temp. on/off, drive mode The trend data output of Apportioned Air-conditioner Usage (Block) The trend data output of Apportioned Air-conditioner Usa...
81 8.8 Peak Cut Status History Data Output If the peak cut function is valid, the peak cut control status, and the history data including the 30-minute unit electric amount and one-day unit working electric amount can be output in the CSV format. Outputting the peak cut status history data 1) Select...
83 8.9 Checking of the gas amount Use this function to check for refrigerant leak from the outdoor unit. Checking the refrigerant amount in the outdoor units 1) Select [Gas amount check] from the [Tool] menu. Select [Tool] and [Gas amount check] from the Management screen's menu. A window to enter t...
84 3) View the “Gas amount check history” window. Press the [All history data] button on the “Gas amount check” window to view the “Gas amount check history” window. On this window, the history of check results will appear. (Maximum 10) *When the latest history cannot be obtained, the results of the...
85 9.1 Charge Display Function When the [Energy monitoring] button at the top left-hand side of the Management screen is clicked, this screen opens. There are two types of monitoring screens: With WHM connection and Without WHM connection. Without WHM connection : 2 displays for the outdoor and indo...
89 Air-conditioning charge display (for indoor unit) Air-conditioning charge display (for watt hour meter) 9.2 Block and Meter Air-conditioning Energy Monitor Display (1) Select the display object 1) Select the display object. [Without meter connection] Select the display object with the [Outdoor un...
90 Settlement date designation display 9.3 Air-conditioning Charge Output (1) Set the automatic output function [Procedure] 1) Select [Settlement date designation] button. When the [Settlement date designation] button at the bottom right-hand side of the screen is clicked, the settlement of date des...
93 4) Select [Output] button. Output : Accepts the setting and advances to the Output type set screen. * The set details are invalidated when the [Cancel] button is clicked on. The above ends whole building output setting. (5) Output type setting The following operations are necessary at output func...
94 9.4 Air-conditioning Charge Basic Setting Set the Standard charges, weekly charges and annual charges, etc., used for the charge function this integrated centralized control software (TG-2000A) system. Set the air-conditioning charge basic setting. [Procedure] 1) Select [Charge set]. When the [Ch...
96 Set the settlement date Since the air-conditioning charge is calculated once a month, set the settlement date. [Procedure] 1) Click [Settlement date designation] button. When the [Settlement-date designation] button at the screen is clicked, the Settlement-date designation setting screen opens. 2...
101 4) Select the [OK] button to end the settings. * If the [Cancel] button is clicked, the settings are canceled and the Annual Charge Pattern Setting screen opens. Changing the pattern Use this function to change a set pattern. [Procedure] 1) Select [Pattern Set/Change]. The Annual Charge Pattern ...
102 Cancel the annual charge pattern [Procedure] 1) Select the date for which an annual charge is set. Click the date for which the annual charge pattern is to be canceled. The setting is canceled if it is the same as the selected pattern. 2) Select the [Pattern Cancel] button from the submenu. If t...
103 9.5 Under Stop Charge “Under stop charge” is the standby used by the outdoor unit crankcase heater. Output and display the apportioned usage and charge under stop [Procedure] 1) Select Apportioned Usage under stop. When the [Apportioned Usage under stop] button of the “Whole building object” at ...
104 9.6 Recalculate the Air-conditioning Charge Recalculate the air-conditioning charge This function recalculates the air-conditioning charge for one month based on the proportional division parameter or apportioning air-conditioner usage already calculated. When the maintenance function was used t...
105 10.1 Graph Display This function can display the graph of ON/OFF status and room temperature for the air conditioner, settlement value for watt hour meter and the value of measuring temperature/humidity. To select a graph [Procedure] 1) To display the screen of selecting a graph. Pull down tool ...
108 It is possible to display the current system configuration, monitoring screen, WHM setting, energy monitoring setting, night mode set-up, System-changeover Set-up and others set-up. This function checks the system status, but cannot change it. 11.1 System Configuration Display For the units corr...
110 (5) Display of indoor unit function setting Display the function setting of each indoor unit and ventilation group for the centralized controller. Displays Yes/No of each function located on the same row as the group No. shown at the left end. The functions arranged from left are Attribute, indo...
111 11. 2 Displaying the DIDO, AI and PI controller setting Pull down menu bar and select [view] and click [DIDO, AI and PI controller setting view]. Current status of DIDO controller (DC), AI controller (MCT), PI controller (MCP) will appear. [Next] [Exit] [Back] buttons in each screen means like b...
113 11.3 PLC for General Equipment Setting Display Click [PLC for general equipment setting view] in the [View] menu (menu bar). The currently set monitor display settings appear. Operate the buttons [Next], [Exit], and [Back], which are displayed on each screen, as follows. Item Details Next Advanc...
115 11.4 Displaying the IC I/O Signal Settings Select [View] – [IC I/O signal set-up" in the menu bar. The IC I/O signal set-up screen will open. Note : Refer to the Site Adjustment "8.9 IC I/O signal Set-up" for details on changing the IC I/O signal settings. Print button Number of ge...
116 11.5 Display of Monitor Display Setting Click [Monitoring screen view] in the [View] menu (menu bar). With the above step, the current monitor display setting contents are displayed. Operate the buttons [Next], [Exit], and [Back], which are displayed on each screen, as follows. Item Details Next...
117 11.6 Watt Hour Meter/Meter Setting Display Select “Watt Hour Meter set-up view” and “Meter set-up view” in the “View” menu bar. The meter setting screen is displayed. Operate the buttons [Next], [Exit], and [Back], which are displayed on each screen, as follows. Item Details Next Advance to the ...
119 11.7 Charge System Display Select “Energy monitoring view” in the “View” menu bar The charge system screen is displayed. Operate the buttons [Next], [Exit], and [Back], which are displayed on each screen, as follows. Item Details Next Advance to the next screen. Exit Return to the Management scr...
120 (3) Electrical specification of outdoor units Select the centralized controller to be displayed by clicking the “ / ” buttons. The outdoor unit crankcase heater set data is displayed. This screen can also be printed with the Print button. (4) Relation between indoor units and watt hour meters Se...
121 (6) Charging blocks Display the charging block setting data. Charging block consists of operation blocks. This screen can also be printed with the Print button. Note : The basic charge, charge setting, and currency setting can be checked or changed with “Charge set” on the “Energy monitoring” ...
122 11.8 Energy Saving Setting Display Select [View] - [Energy saving setting] in the menu bar. The energy saving setting screen will open. Operate the buttons [Next], [End], and [Back], which are displayed on each screen, as follows. Item Details Next Open the next screen. End Return to the Managem...
123 (3) Displaying the energy saving/peak cut set-up The energy saving control or peak cut control details are displayed. The screen is the peak cut control setting screen. The screen can be printed by pressing the Print button. Note : For the "energy saving control" function, only the low...
126 12.1 Contents Click “Contents” in the “Help” menu (menu bar). The following manuals are accessible from the Help menu. Adobe® Reader® is required to read these manuals. (Version 10 or later recommended) Manuals PDF Normal Startup Startup in the Wide Area Mode System Screen Management Screen Syst...
127 The following describes the precautions to be taken when operating the system. Always read this section before using the system. Also, read Section 2.3 Items to Check before Starting Operation. 13.1 Usage Right 13.2 Operation and Setting Precautions (1) Change of system configuration, monitoring...
128 13.3 Air-conditioning Charge Precautions (1) Using the charge function When using this program’s charge function, we recommend that you consent to “Collect air-conditioning charges (including temporary action when failure occurs) by proportional division calculation considered by operation sta...
129 (2) Air-conditioning charge calculation (proportional division) This is our original method that calculates the total electricity consumption by checking the operating status of the air conditioners. This function supports apportioned electricity charge. The following precautions are required....
131 For maintenance and service, please contact a Mitsubishi official sales electric office or supplier. *Contact the local manufacturer if any faults occur in the locally prepared computer or HUB, etc. 14. Maintenance and Service
132 These attached sheets describe using the charge calculation tool (Excel file) that supports the air- conditioning charge calculation for each charge block by using the air-conditioning charge proportion result output file and the value indicated by the watt hour meter. It is possible for this to...
133 3) Select the data file. Select the data file to be read. 4) Select the [Open] button. To read the data file, select the [Open] button, by which the Excel screen of "Air-conditioning charge calculation support tool from calculation proportion" is displayed automatically by the different ...
134 * Air-conditioning charge support.xls closes, and an Excel file is created and displayed in a new book. 5) Input the data of the necessary items. In this case, input the necessary data shown below. Billing month and year 3. Method for developing printing charges The following describes the pro...
135 4. Change of bill form The following describes the procedure to change the Bill form output for each charge block. 1) Start the file. Double-click the ChargeCalc.xls or AirConCharge.xls file with Explorer to open the file using Excel, by which the charge calculation screen is displayed. 2) Selec...
136 This appendix explains a support tool that displays trend graphs, using the CSV output files of the trend and peak-cut data. This support tool displays simple trend graphs. Other tools can be used to display more detailed trend graphs. 1. Preparation Prepare the following items to display the tr...
137 Examples of screens showing the trend graphs are shown below. Example of intake temperature trend graph Example of peak cut (monthly report) WHM trend graph Example of WHM trend graph Example of peak cut (monthly report) trend graph Example of peak cut (daily report) trend graph Peak cut – amoun...
Mitsubishi Manuals
-
Mitsubishi PKA-A18GA
User Manual
-
Mitsubishi PKA-A18GA
Installation Manual
-
Mitsubishi PKA-A18GAL
User Manual
-
Mitsubishi PKA-A18GAL
Installation Manual
-
Mitsubishi PCA-A42GA1
User Manual
-
Mitsubishi PCA-A42GA1
Installation Manual
-
Mitsubishi MSZ-FH18NA
User Manual
-
Mitsubishi MSZ-FH18NA
Installation Manual
-
Mitsubishi MSZ-D36NA
User Manual
-
Mitsubishi MSZ-D36NA
Installation Manual
-
Mitsubishi WD-82742
User Manual
-
Mitsubishi MSZ-FE09NA
User Manual
-
Mitsubishi MSZ-FE09NA
Installation Manual
-
Mitsubishi LT-46164
User Manual
-
Mitsubishi MSY-D36NA-8
User Manual
-
Mitsubishi MSY-D36NA-8
Installation Manual
-
Mitsubishi MSY-A15NA-1
User Manual
-
Mitsubishi MSY-A15NA-1
Installation Manual
-
Mitsubishi WD-73638
User Manual
-
Mitsubishi PKA-A36FA
User Manual