Page 2 - COP; D AUTO; Programmed air distribution; Quiet operation; ZJX; SRK; Wall Mounted type; Series
Industry leading energy efficiency and reliability from our advanced technology. COP 5.71 SRK20ZJX-S in the cooling operation 3D AUTO Programmed air distribution Quiet operation Sophisticated design ZJX SRK Wall Mounted type Series
Page 4 - Energy; Employment of lead-free solder; Adapted to RoHS directive; ENERGY LABEL “Class A”; DC compressor motor; INVERTER; DC; PAM; PowerActiveModule; DC PAM inverter; EER in Cooling
4 High Efficiency High Efficiency Energy Manufacturer Outside unit Inside unit Annual energy consumption, kWh in cooling mode kW Cooling output E nergy e fficiency r atio kW Heat output Type Heating performance Noise M o r e e f fi c i e n t L e s s e f fi c i e n t (Actual consumption will depend o...
Page 5 - High Efficiency; New propeller fan
High Efficiency 5 R e s i d e n t i a l A i r C o n d i t i o n e r s High Efficiency Our Latest Technologies Applied to all inverter models New propeller fan The new propeller fan was carefully matched with a fan motor in order to keep the same capacity as that of previous models with less electric...
Page 6 - motors make 3 independent controls; Airflow; Programmed 3D AUTO
6 SRK-ZJX, SRK-ZJ SRK63/71/80ZE, Manual Setting only Applied models 3D AUTO Swing Vertical Swing Horizontal Air Scroll 8 Direction Swing 1 2 3 4 8 7 6 5 Swing Spot Wide 3 4 2 1 Cool Shower Cool Shower Floor Heating Floor Swing Swing Swing Hi-Power (Quick) Wide Swing (Every Corner) Center (Long) Wide...
Page 7 - powerful; Positioning of Installation
All SRK Applied models 17m 17m 17m 17m SRK63/71/80ZE (in cooling operation) SRK50/60ZJX,SRK63/71/80ZE Applied models 15m 15m 15m 15m SRK50/60ZJX (in cooling operation) powerful Fast Slow Colors in the figure show the air speed. SRK-ZJX Applied models New previous 80% increased SRK-ZJX, SRK-ZJ Applie...
Page 8 - Clean Air; First in the world; Catching Allergen; Cooling Operation; Heating Operation; Self Clean operation; Allergen Clear system
8 Clean Air Stop run 2hrs Normal operation Clean operation Shuts off automatically First in the world 20 of Patent Pending Situation of mold after one week Fungal mycelia expand. The spore of mold doesn't germinate. When you execute “Self Clean Operation” When you don’t execute “Self Clean Operation...
Page 9 - First in; Allergen Clear Filter; Enzyme fi lter; Photocatalytic Washable Deodorizing Filter
9 R e s i d e n t i a l A i r C o n d i t i o n e r s Clean Air Coupling Cell wall Filter fiber Enzyme Enzyme Bacterium Powerful sterilizing effect Enzyme's sterilizing mechanism Airflow Conventional Filter Enzyme Filter Analysis Zone Analysis Zone Sterilization Mechanism -COOH H 2 N- Protein struct...
Page 10 - Advanced Technology; Anti-microbial indoor fan
10 Advanced Technology Live Bacteria Count on Measured Test Pieces Test Pieces 1) Products with Antimicrobial and Antifungal Treatment Tested Contaminant Measurement Test Pieces Bacteria Count Per Test Piece Measurement 1 Measurement 2 Measurement 3 Escherichia coli IFO 3972 coli Aspergillusniger St...
Page 11 - Wide Operation Range; The secret of quiet operation; Three sensors
11 R e s i d e n t i a l A i r C o n d i t i o n e r s Advanced Technology All SRK, SRF Applied models SRK50/60ZJX, SRK-ZESRF-50ZJX Applied models 60dB 50dB 40dB 30dB 21dB SRK20ZJX-S (In the Cooling Lo mode) 70dB 60dB 50dB 40dB 30dB 20dB 10dB 0dB Comparison with familiar noises in our everyday life ...
Page 12 - Product line up
12 Product line up Model Capacity Range (kW: Rated cooling capacity) Page 2.0 2.5 3.5 5.0 6.0 6.3 7.1 7.5 H E AT P U M P D C IN V E R TE R SRK-ZJX Series 20ZJX-S 25ZJX-S 35ZJX-S 50ZJX-S 60ZJX-S 14 SRK-ZE Series 63ZE-S1 71ZE-S1 80ZE-S2 16 SRK-ZJ Series 20ZJ-S 25ZJ-S 35ZJ-S 50ZJ-S 17 SRF-ZJX 25ZJX-S 3...
Page 13 - Functions; MC; Filter; Operation; System
13 R e s i d e n t i a l A i r C o n d i t i o n e r s Functions Comfortable Functions Automatic Operation The air conditioner automatically selects from heating, cooling or dry operation. "HI POWER" Operation The unit can operate continuously in HI POWER mode for 15 minutes. This mode is us...
Page 14 - NEW
14 INVERTER HEAT PUMP MODEL (High COP) SRK-ZJX R410A SRC20 ZJX-S, SRC25ZJX-S, SRC35ZJX-S SRC50 ZIX-S, SRC60ZIX-S Series Wall Mounted type Standard equipment SRK20ZJX-SSRK25ZJX-SSRK35ZJX-S 10m 15m Maximum height difference Maximum pipe length Refrigerant pipe length SRK50ZIX-SSRK60ZIX-S 20m 30m Maxim...
Page 15 - Industry leading COP levels; Operation section
15 R e s i d e n t i a l A i r C o n d i t i o n e r s Inverter Heat Pump Model (High COP) OPERATION MODE select button ON/OFF (luminous) button AIR FLOW (UP/DOWN) button AIR FLOW (LEFT/RIGHT) button 3D AUTO button ALLERGEN CLEAR button RESET switch OFF TIMER button FAN SPEED button HI POWER/ECONO b...
Page 17 - Inverter Heat Pump Model; INVERTER HEAT PUMP MODEL
17 R e s i d e n t i a l A i r C o n d i t i o n e r s Inverter Heat Pump Model INVERTER HEAT PUMP MODEL INVERTER HEAT PUMP MODEL 19 18 Comfortable Functions CLASS A A SRC25ZJP-SSRC35ZJP-S SRK-ZJP SRK25ZJP-SSRK35ZJP-S 10m 15m Maximum height difference Maximum pipe length Refrigerant pipe length SRK5...
Page 18 - Floor type
18 Inverter Heat Pump Model (High COP) INVERTER HEAT PUMP MODEL (High COP) SRF-ZJX R410A SRC25ZJX-S, SRC35ZJX-S SRC50ZIX-S SRC25ZJX-S, SRC35ZJX-S 10m 15m Maximum height difference Maximum pipe length Refrigerant pipe length SRC50ZJX-S 20m 30m Maximum height difference Maximum pipe length Floor type ...
Page 19 - Sophisticated Design
19 R e s i d e n t i a l A i r C o n d i t i o n e r s Right Left Rear Left rear Left downward Downward Sophisticated Design With a classy semi fl at front panel in chic white, this series fi ts in all kinds of rooms and creates a relaxing atmosphere. Choice of wall hanging, fl oor standing or behin...
Page 20 - Inverter Multi-Split Model; Industry Leading COP levels; SRF; SRR; Super Compact type; OUTDOOR UNIT
20 Inverter Multi-Split Model Inverter Multi-split System Inverter Multi-split System PIPING LENGTH - The maximum length and weight of this indoor and outdoor units is shown below. Limit The maximum piping length of the refrigerant pipes for the outdoor units, and the maximum height difference for t...
Page 21 - Inverter Multi Split
21 R e s i d e n t i a l A i r C o n d i t i o n e r s Inverter Multi Split Inverter Multi-split System Inverter Multi-split System PIPING LENGTH - The maximum length and weight of this indoor and outdoor units is shown below. Limit The maximum piping length of the refrigerant pipes for the outdoor ...
Page 22 - Inverter Multi-Split System; INVERTER MULTI-SPLIT SYSTEM; Multi System; INDOOR UNIT; Ceiling Concealed type
22 Inverter Multi-Split System INVERTER MULTI-SPLIT SYSTEM Multi System Multi System INDOOR UNIT FUNCTION SRF-ZJX SRF-ZJX SRK-ZJX Wall mounted type SRK-ZJX Wall mounted type SPECIFICATIONS Model Cooling capacityHeating capacity Sound power level Sound pressure level kWkW dB(A)dB(A)dB(A)dB(A) l/s mm ...
Page 24 - Inverter Cooling Only
24 Inverter Cooling Only R410A SRK-YJ Wall Mounted type SRC10YJ-S, SRC13YJ-S SRC18YJ-S SRK10YJ-SSRK13YJ-SSRK18YJ-S 10m 15m Maximum height difference Maximum pipe length Refrigerant pipe length FUNCTION Comfortable Functions Convenient & Economy Functions On Timer 24h Timer Economy DRY OFF Timer ...
Page 25 - Combinations; Wired remote control can be connected; Control option; Can be connected to SUPERLINK-
25 R e s i d e n t i a l A i r C o n d i t i o n e r s Combinations CnT terminal is equipped XR5 CnT XR1 ~ 4 : DC12v XR5 : 220 ~ 240V XR3 XR1 XR2 XR4 XR5 XR1XR2XR3XR4 output1 (run)output2 (heat)output3 (comp on)output4 (alarm) common Power source in put Remote surveillance system Humidifier linkage ...
Page 26 - Ceiling Concealed; Dimensions
26 Dimensions INDOOR UNIT Unit: mm Ceiling Concealed SRR25ZJ-S SRR35ZJ-S SRR50ZJ-S SRR60ZJ-S SRF25ZJX-S SRF35ZJX-S SRF50ZJX-S Floor standing type 4way ceiling cassette type FDTC25VD FDTC35VD FDTC40VD FDTC50VD FDTC60VD Wall mounted type INDOOR UNIT Unit: mm SRK20ZJX-S SRK25ZJX-S SRK35ZJX-S SRK50ZJX-S...
Page 30 - VRF inverter multi-system; II; Water to Water Heat Pump
30 VRF inverter multi-system Air-Conditioners Water heat exchanger + Heat storage unit Refrigerant Water pipe (for Air Conditioning) Water pipe (for Sanitary) Sa nita ry Sanitary Sa nita ry Sanitary He a ting Heating Cooling Cooling R a dia tor or Fa n coil Radiator or Fan coil Floor He a ting Floor...
Page 32 - National Contact Information:; MRE SPARE PARTS
Before starting use Heating performance The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7C and indoor temperature of 20C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops...