Page 2 - CONDITIONS OF USE FOR THE PRODUCT
A-1 CONDITIONS OF USE FOR THE PRODUCT (1) Mitsubishi programmable controller ("the PRODUCT") shall be used in conditions;i) where any problem, fault or failure occurring in the PRODUCT, if any, shall not lead to any major or serious accident; and ii) where the backup and fail-safe function a...
Page 4 - REVISIONS
A-3 REVISIONS * The manual number is noted at the lower right of the top cover. 2007 MITSUBISHI ELECTRIC CORPORATION Print Date *Manual Number Revision Aug., 2007 IB(NA)-0800402-A First printing Mar., 2008 IB(NA)-0800402-B Section 2.2, 6.1 Mar., 2010 IB(NA)-0800402-C Section 2.2 CONDITIONS OF USE ...
Page 5 - CONTENTS; GENERIC TERMS AND ABBREVIATIONS; Generic term/Abbreviation
A-4 CONTENTS 1. OVERVIEW .................................................................................................... 1 1.1 Overview................................................................................................... 11.2 Included Parts............................................
Page 6 - POINT
1 1. OVERVIEW 1.1 Overview This user’s manual describes the specifications, configuration device, part names and setting, and implementation and installation of the QA6ADP QA conversion adapter module.For contents that are not described in this manual such as safety precautions, EMC and low voltage ...
Page 7 - This section describes parts included with this module.
2 1.2 Included Parts This section describes parts included with this module. Product name Model Quantity Remarks QA6ADP QA conversion adapter module QA6ADP 1 Adapter module mounting bracket 1 Mounting bracket fixing screw 1 Board fixing screw 1 This manual 1
Page 8 - SYSTEM CONFIGURATION; System Configuration
3 2. SYSTEM CONFIGURATION 2.1 System Configuration This section describes the system configuration and restrictions when the QA6ADP is used. (1) The QA6ADP+A5 B/A6 B is only applicable for the following CPU modules. • High Performance model QCPU • Universal model QCPU whose serial number (first ...
Page 9 - (8) The bus connection with GOT is not available for the
4 (8) The bus connection with GOT is not available for the QA6ADP+A5 B/A6 B. 25 3 24 Q series compatible extension base unit(The Q5 B/Q6 B is connected to the main base unit or the Q5 B/Q6 B.) Main base unit ......A68B ...QA68B .........Q38B ..............Q68B CPU module Stage number setting con...
Page 10 - Configuration Device List; (1) Extension base unit mountable on the QA6ADP
5 2.2 Configuration Device List (1) Extension base unit mountable on the QA6ADP The following shows extension base units that can be mounted on the QA6ADP. (2) Module mountable on the extension base unit where the QA6ADP is mountedThe following shows modules that can be mounted on the extension base...
Page 13 - General Specifications; This section describes general specifications of the QA6ADP.
8 3. SPECIFICATIONS 3.1 General Specifications This section describes general specifications of the QA6ADP. *1 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises.C...
Page 14 - Performance Specifications; Item
9 *2 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used.Pollution level 2 is when only non-conductive pollution occurs. A temporary conductivity caused by condensing must be expected occasionally. *3 Do not use or stor...
Page 15 - PART NAMES AND SETTING; This section describes part names of the QA6ADP; Name
10 4. PART NAMES AND SETTING 4.1 Part Names This section describes part names of the QA6ADP . No. Name Application 1) Extension cable connector Connector for sending/receiving signals to the main base unit or the other extension base unit and connecting an extension cable. 2) Stage number setting co...
Page 16 - Extension Stage Number Setting; (1) Extension stage number setting of the QA6ADP
11 4.2 Extension Stage Number Setting Set the number of extension stages to both the QA6ADP and the extension base unit.The same stage number should be set to both the stage number setting connector of the extension base unit and that of the QA6ADP. (1) Extension stage number setting of the QA6ADP T...
Page 17 - MOUNTING AND INSTALLATION
12 5. MOUNTING AND INSTALLATION 5.1 Mounting/Removal of QA6ADP (1) Mounting of the QA6ADP The following shows procedures for mounting the QA6ADP on the extension base unit. side connector Adapter modulemounting screw Mounting bracketfixing screw screw Adapter module Connect the Q series extension ca...
Page 19 - Connection/Disconnection of Extension Cable; (1) Precautions for handling an extension cable; Model
14 5.2 Connection/Disconnection of Extension Cable (1) Precautions for handling an extension cable • Do not step on an extension cable. • When laying an extension cable, the minimum bend radius of the cable should be 55 mm (2.17 inch) or more. If it is less than 55 mm (2.17 inch), malfunction may oc...
Page 22 - PRECAUTION FOR USING QA6ADP; Current Consumption of QA6ADP
17 6. PRECAUTION FOR USING QA6ADP 6.1 Current Consumption of QA6ADP Since 5VDC is supplied to the QA6ADP from the power supply module of the main base unit, take the current consumption of the QA6ADP into consideration when selecting the power supply module for the main base unit. *1 The quantity of...
Page 23 - Voltage Drop of Extension Cable
18 In case of the above system, use the QA6ADP when the current consumption of the power supply module mounted on the main base unit meets the following formula. 6.2 Voltage Drop of Extension Cable Since 5VDC is supplied to the QA6ADP from the power supply module mounted on the main base unit, the v...
Page 25 - COMPATIBLE MODELS LIST; This chapter describes external dimensions of the QA6ADP.; Power supply module, Extension cable
20 7. COMPATIBLE MODELS LIST This chapter describes external dimensions of the QA6ADP. Power supply module, Extension cable (M5 mounting screw) (for mounting module) 4- f 6mounting hole 2 6-M4 screw A series extension base unitthat you have already had QA6ADP QA conversionadapter module Handle 9 (0....
Page 26 - WARRANTY
WARRANTY Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages...