Page 2 - Note; Symbols used in the text; : Indicates a part which must be grounded.; Disposing of the unit; When you need to dispose of the unit, consult your dealer.
2 This symbol mark is for EU countries only.This symbol mark is according to the directive 2002/96/EC Article 10 Information for users and Annex IV, and/or to thedirective 2006/66/EC Article 20 Information for end-users and Annex II. Your MITSUBISHI ELECTRIC product is designed and manufactured with...
Page 3 - Indoor Unit; Ceiling Suspended
3 ■ Indoor Unit PKA-RP·HAL PCA-RP·KA PCA-RP·HA PSA-RP·GA Fan speed 3 speeds + Auto 4 speeds + Auto 2 speeds 2 speeds Vane Auto with swing Auto with swing Manual Manual Louver Manual Manual Manual Auto with swing Filter Normal Long-life Oil Long-life Filter cleaning indication 100 hr 2,500 hr 100 hr ...
Page 4 - OPERATION; Wired Remote-Controller; “PLEASE WAIT” message; Display Section
4 ˚ F ˚ C ˚ F ˚ C ERROR CODE AFTER TIMER TIME SUN MON TUE WED THU FRI SAT ONOFF HrAFTER FILTER FUNCTION ONLY1Hr. WEEKLY SIMPLE AUTO OFF PAR-21MAA ON/OFF FILTER CHECK OPERATION CLEAR TEST TEMP. MENU BACK DAY MONITOR/SET CLOCK ON/OFF 2. Parts Names ■ Wired Remote-Controller Note: ● “PLEASE WAIT” messa...
Page 5 - Wireless Remote-Controller; spected. Consult your dealer for service.; Battery installation/replacement; Outdoor unit; Top cover
5 1 2 3 2. Parts Names ■ Wireless Remote-Controller ■ When using the wireless remote controller, point it towards the receiver on the indoor unit. ■ If the remote controller is operated within approximately 2 minutes after power is supplied to the indoor unit, the indoor unit may beep twice as the u...
Page 7 - from the speed shown the remote controller display.
7 5. Operation 5.2. Mode select ■ Press the operation mode ( ) button 2 and select the opera- tion mode 2 . Cooling mode Drying modeFan mode Heating mode <Only heat pump type> Automatic (cooling/heating) mode <Only heat pump type>Ventilation mode Only indicated on the following condition...
Page 8 - For LOSSNAY combination; No display; During swing operation, the arrow display
8 5. Operation Note: ● Available directions depend on the type of unit connected. ● In the following cases, the actual air direction will differ from the direction indicated on the remote controller display. 1. While the display is showing “STAND BY” or “DEFROST”. 2. Immediately after starting heat ...
Page 9 - Setup Matrix; before pressing the Filter butto; Be sure that the
9 C C TIME SUN WEEKLY 10 C TIMER SUN ONOFF WEEKLY 8 9 1 Timer Settings 1. Be sure that the weekly timer indicator is visible on the screen (at 1 ). 2. Press the Timer Menu button 2 so that “Monitor” is indicated on the screen (at 8 ). 3. Press the Timer On/Off (Set Day) button 9 as necessary to sele...
Page 10 - before pressing the Filter button; Be sure; Examples
10 <How to Set the Simple Timer> 6. Timer Action (On or Off)* “— —” is displayed if there is no setting. Timer Setting ON HrAFTER SIMPLE 4. With “ON” or “OFF” showing at 3 : Press the appropriate Set Time but- ton as necessary to set the hours to ON (if “ON” is displayed) or the hours to OFF (...
Page 11 - Your entry will be cancelled if you press the Mode (Return) button
11 <Checking the Current Auto Off Timer Setting> AFTER TIMER OFF AUTO OFF Timer Setting ˚ C ˚ C AFTER OFF AUTO OFF AUTO OFF 1. Be sure that the “Auto Off” is visible on the screen (at 1 ). 2. Hold down the Timer Menu button 2 for 3 seconds so that “Monitor” is indicated on the screen (at 4 ). ...
Page 13 - Function Selection; Function selection of remote controller
13 8. Function Selection Function selection of remote controller The setting of the following remote controller functions can be changed using the remote controller function selection mode. Change the setting whenneeded. Item 1 Item 2 Item 3 (Setting content) 1. Change Language (“CHANGE LAN-GUAGE”) ...
Page 16 - Selecting language
16 8. Function Selection [Dot display table] Waiting for start-up Operation mode Cool Dry Heat Auto Auto(Cool) Auto(Heat) Fan Ventilation Stand by(Hot adjust)Defrost Set temperature Fan speed Not use button Check (Error) Test run Self check Unit function selection Setting of ventilation CHANGE LANGU...
Page 17 - SW; Care and Cleaning; Emergency Operation for Wireless Remote-controller; When the remote controller cannot be used; Cooling only type; Operation Monitor Display; The orange lamp follows the
17 E.O. SW 10. Care and Cleaning ON/OFF TEMP. C C FILTER Note:• Details of emergency mode are as shown below. Operation mode COOL HEAT Set temperature 24°C 24°C Fan speed High High Airfl ow direction Horizontal Downward 4 (5) ■ Indicates that the fi lter needs cleaning. Clean the fi lter. ■ When res...
Page 18 - pieces
18 10. Care and Cleaning / 0 1 PSA-RP·GA 1 Open the intake grille. 2 Hold the knob on the fi lter then pull the fi lter up in the direction of an arrow. To replace the fi lter after cleaning, be sure to insert the fi lter far enough until it fi ts into the stopper. A Filter B Intake Grille C Knob D ...
Page 19 - SIMPLE
19 11. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) Air conditioner does not heat or cool well. ■ Clean the fi lter. (Airfl ow is reduced when the fi lter is dirty or clogged.) ■ Check the temperature adjustment and adjust the set temperature. ■ Make sure that...
Page 22 - Printed in Japan; Please be sure to put the contact address/telephone number on
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN BG79U612H03 Printed in Japan Please be sure to put the contact address/telephone number on this manual before handing it to the customer. BG79U612H03.indd 22 BG79U612H03.indd 22 2008/12/11 9:03:08 2008/12/11 9:03:...