Mitsubishi MS-30SV- Manuals
Mitsubishi MS-30SV– User Manual in PDF format online.
Manuals:
User Manual Mitsubishi MS-30SV
Summary
New Line up! The " " logo is printed on the products compatible with CC-Link Ver. 2. ■ Master Module for Q Series QJ61BT11N ■ Analog Module AJ65VBTCU-68ADVN/AJ65VBTCU-68ADIN AJ65VBTCU-68DAVN ■ Embedded I/O Adapters AJ65MBTL1N-□ ■ CC-LinkーCC-Link/LT Bridge M...
C ontents ■ Total Network Solution ■ CC-Link Family ■ Features of CC-Link ■ System Configuration Examples ■ Application Examples ■ Application Examples from ■ Product Information ・ Master/Local Modules ・ Remote I/O Modules ・ Analog Modules ・ High-Speed Counter Modules ・ Positioning Modul...
Total Network Solution 2 ・ Total Network Solution Q12HCPU USB PULL RS-232 QX42-S1 QY42P PULL POWER Q25HCPU USB QX42-S1 QY42P PULL MODE RUN ERR USER BAT BOOT MODE RUN ERR USER BAT BOOT RS-232 Q12HCPU USB PULL RS-232 QX42-S1 QY42P PULL POWER Q25HCPU USB QX42-S1 QY42P PULL MODE RUNERR USER BAT BOOT MOD...
Total Network Solution 3 MELSECNET/H Ethernet CC-Link CC-Link /LT Q12HCPU USB PULL RS-232 QX42-S1 QY42P PULL POWER Q25HCPU USB QX42-S1 QY42P PULL MODE RUNERR USER BAT BOOT MODE RUNERR USER BAT BOOT RS-232 From information management to production control, machine control, device and I/O control ...L...
Family 4 ・ CC-Link Family To expand open network possibilities to every cor ner o f a field.The CC-Link family realizes flexible system configuration. For machine control inside line CC-Link is a high-speed field network that can handle both control and information together. At high communication sp...
5 CC-Link Family Remote I/O stations Fast response Ease of working by connection of connectorsEase of extension and addition Communication and power supply lines are integrated into one line.2-, 4-, 8- and 16-point remote I/O units are available. For networking inside a panel/machine CC-Link/LT is a...
Features 6 ・ Features of CC-Link CC-Link is a high-performance network that utilizes high speed communications (10 Mbps industry fastest), in order to allow transmission of bit data and word data at high speed and maximum capacity. CC-Link utilizes the highly stable cyclic transmission, which gives ...
7 Features of CC-Link CC-Link can transmit bit data and word data at high speed with cyclic transmission, and the transmission time is stable as well (guarantee for regularity). The cyclic transmission time (link scan time) is not affected by irregular message transmission (transient transmission) t...
System the line-up CL1PAD1 POWER +2 4V 24 G DBDA 24G DBDA +24V LCNET/ POWER LINK CL2Y8-TP1B2 Y0Y1Y2Y3 Y4Y5Y6Y7 40 20 10 8 4 2 1 PW L RUN L ERR. STATION NO. 0.5ms1.5ms ON OUT 0 1 2 3 4 5 6 7 IN X0X1X2X3 0 1 2 3 PW L RUN L ERR. STATION NO. ON PW L RUN L ERR. 0123456789ABCDEF CL2X16-D1M1V ST.No. 1 2 3 ...
Application 10 ・ Application Examples Bottle filling line System example using CC-Link 1 The total extension distance of CC-Link is 1.2km (156kbps). However it can be extended up to 13.2km by using repeaters. Using a repeater module, a T branch can be connected randomly even at 10Mbps communication ...
11 Application Examples System example combining and Improved maintainability Ease of connecting various sensors CC-Link-CC-Link/LT bridge for seamless communication 2 You can choose the optimum device from among many partner products to construct a system with a high degreeof flexibility. Wide se...
Application CC-Link supports a number of different applications. ● Main Requirements ● Introducing CC-Link: Key Advantages ● Main Requirements ● Introducing CC-Link: Key Advantages ● Main Requirements ● Introducing CC-Link: Key Advantages 12 ・ Application Examples from the Industry Semiconduct...
Master/Local Remote I/O Analog High-Speed Counters Positioning HM I Repeaters RS-232 Interfaces Option Software Others Technical Information C C -Lin k- CC -L in k / L T B rid ge Mo du le s Support PC Interfaces Peripheral Device Connection Product Information 15 FX Series Interface Blocks, Inverter...
16 QJ61BT11N AJ61QBT11 FX 2N -16 CCL-M A1SJ61QBT11 AJ61BT11 A1SJ61BT11 Master/local modules control the CC-Link system with total freedom. Master/Local Modules Overview Overview For Q Series For QnAS Series For AnS Series For FX Series For A Series For QnA Series Product description Page 18 Product ...
Model name QJ61BT11N AJ61QBT11 A1SJ61QBT11 AJ61BT11 A1SJ61BT11 FX 2N -16CCL-M * 1 The number of occupied stations at a local station is set by a parameter in GX Developer. * 2 The number of occupied stations at a local station is set by the "condition setting switch" on the front face of the...
● Features 18 For Q CPU QJ61BT11N Master/Local Module PLC CPU Local station PLC CPU It is possible to set the CC-Link parameters from the parameter setting screen of GX Developer (up to four master stations).Alternatively, the CC-Link parameters can be set via a sequence program (using dedicated...
● External Dimension Diagram 19 ■ Functions for CC-Link: Cyclic transmission, expanded cyclic transmission, transient transmission, station-to-station cable length relaxation ■ Expanded cyclic setting at local station Single, double, guadruple, octuple ■ Internal current consumption 0.46 A ■ Weig...
● Features ● Specification See page 154 for the general specifications. ■ Internal current consumption 0.45 A ■ Weight 0.4 kg See page 148 for the CC-Link common specifications. 20 ■ CC-Link parameters It is possible to set the CC-Link parameters from the parameter setting screen of GX Develo...
● Features ● Specification See page 154 for the general specifications. ■ Internal current consumption 0.4 A ■ Weight 0.25 kg See page 148 for the CC-Link common specifications. 22 ■ CC-Link parameters It is possible to set the CC-Link parameters from the parameter setting screen of GX Develo...
■ Internal current consumption 0.45 A ■ Weight 0.4 kg See page 148 for the CC-Link common specifications. 24 A0J2(H)CPU AnSCPU A1SCPUC24-R2 AnSHCPU AnUSCPU ACPU AnACPU AnUCPU No restriction PLC CPU I/O mode * 2 2 modules 1 module 2 modules 6 modules 2 modules 6 modules Intelligent mode * 2 ■ Auto...
(Remote I/O station) (Remote I/O station) (Remote device station) (Remote device station) (Master station) ■ Internal current consumption (5 VDC): 5 VDC supplied by the module itself. (The 5 VDC sup- ply of the PLC is not used.) ■ External current consumption (24 VDC): 150 mA ■ Weight 0.4 kg See...
Overview 31 Remote I/O Modules ● Overview ■ A remote I/O module occupies one remote I/O station. ■ Installation on the control board can be done either with screws or using a DIN rail. ■ Ultra-miniature compact size saves space. ■ It is possible to install the module from any of the six directions...
32 Remote I/O Modules ● List of Models Input module I/O module Output module Compact type remote I/O module Compact type remote I/O module Compact type remote I/O module Remote I/O module Embedded input adapter Embedded output adapter Embedded I/O adapter remote I/O module Remote I/O module Produc...
33 Master/Local Remote I/O Analog High-Speed Counters Positioning HM I Repeaters RS-232 Interfaces Option Software Others Technical Information C C -Lin k- CC -L in k / L T B rid ge Mo du le s Support PC Interfaces Peripheral Device Connection Memo
Guide Master/Local Remote I/O Analog High-Speed Counters Positioning HM I Repeaters RS-232 Interfaces Option Software Others Technical Information C C -Lin k- CC -L in k / L T B rid ge Mo du le s Support PC Interfaces Peripheral Device Connection If the external connection isof this type … ? Select ...
36 DIN rail Finger protector 12/24 VDC 12/24 VDC 12/24 VDC 12/24 VDC 12/24 VDC 12/24 VDC 12/24 VDC 12/24 VDC 12/24 VDC 12/24 VDC 12/24 VDC 12/24 VDC 24 VDC/240 VAC 24 VDC/240 VAC 100 to 240 VAC 100 to 240 VAC 12/24 VDC 24 VDC/240 VAC 12/24 VDC Self-up screw Round solderless terminal Terminal block F...
38 ● AJ65SBTB1-8 □ ● AJ65BTB1-16 □ ● AJ65BTB2-16 □ ● AJ65SBTB1-16 □ ● AJ65SBTB2-8 □ ● AJ65SBTB3-8 □ ● AJ65SBTB2N-8 □ ● AJ65SBTB32-8 □ ● AJ65SBTB1-32 □ ● AJ65SBTB2-16 □ ● AJ65SBTB3-16 □ ● AJ65SBTB2N-16 □ ● AJ65SBTB32-16 □ AJ65SBTB1-8D X0 1 2 3 4 5 6 7 X0 X2 X4 X6 X1 X3 X5 X7 DA DG +24V 24G DB SLD (...
48 AJ65SBTC1-32D AJ65SBTC1-32D1 AJ65SBTC4-16D AJ65VBTCU3-8D1 AJ65VBTCU3-16D1 DC input DC input DC input DC input DC input Photocoupler Photocoupler Photocoupler Photocoupler Photocoupler Photocoupler Photocoupler Photocoupler Photocoupler 32 points 32 points 16 points 8 points 16 points 24 VDC 24 VD...
Master/Local Remote I/O Analog High-Speed Counters Positioning HM I Repeaters RS-232 Interfaces Option Software Others Technical Information C C -Lin k- CC -L in k / L T B rid ge Mo du le s Support PC Interfaces Peripheral Device Connection 54 Embedded I/O Adapters AJ65MBTL1N- □ Remote I/O Produc...
Master/Local Remote I/O Analog High-Speed Counters Positioning HM I Repeaters RS-232 Interfaces Option Software Others Technical Information C C -Lin k- CC -L in k / L T B rid ge Mo du le s Support PC Interfaces Peripheral Device Connection 58 Isolation method Surge suppression Current consumption...
62 Terminal resistor setting switch Terminal resistor setting switch AJ65FBTA2-16T AJ65FBTA2-16TE 1 2 3 4 5 LINK IN SLD DB DG DA No pin Communication circuit Pin no. LINK OUT SLD DB DG DA Vacant 1 2 3 4 5 1 2 3 4 5 +24V Y1 Vacant Y0 Vacant Y0 ― Y1 UNIT POWER +24V(UN...
1 2 4 1 2 4 10 20 40 8 ON STATION NO. B RATE X0-XF X10-X1F X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F NC NC NC NC X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC NC COM COM MITSUBISHI A J65SBTCF1-32D 66 ● AJ65SBTCF1-32 □ Operation LED display PW L RUN L ERR LED name Item chec...
New New Master/Local Remote I/O Analog High-Speed Counters Positioning HM I Repeaters RS-232 Interfaces Option Software Others Technical Information C C -Lin k- CC -L in k / L T B rid ge Mo du le s Support PC Interfaces Peripheral Device Connection 72 AJ65SBT-64AD AJ65BT-64AD AJ65SBT-62DA AJ65BT...
Master/Local Remote I/O Analog High-Speed Counters Positioning HM I Repeaters RS-232 Interfaces Option Software Others Technical Information C C -Lin k- CC -L in k / L T B rid ge Mo du le s Support PC Interfaces Peripheral Device Connection 73 AJ65VBTCU-68ADVN AJ65VBTCU-68ADIN AJ65SBT-64AD AJ65BT-64...
74 Model name AJ65VBTCU-68ADVN AJ65VBTCU-68ADIN Analog input Digital valueInput/output characteristics Input range switchingOffset/gain settingMaximum conversion speedAbsolute maximum inputNumber of analog input pointsStation typeNumber of occupied stations,Expanded cyclic settingCC-Link-compatible ...
Master/Local Remote I/O Analog High-Speed Counters Positioning HM I Repeaters RS-232 Interfaces Option Software Others Technical Information C C -Lin k- CC -L in k / L T B rid ge Mo du le s Support PC Interfaces Peripheral Device Connection 76 ■ Analog Input ● Four channels (voltage input/current in...
● 各部の名称と設定 AJ65BT-64AD V+ I+ COM SLD 500KΩ 500KΩ 250Ω V+ I+ COM SLD 500KΩ 500KΩ 250Ω FG1 CH1 +15V ー15V GND *4 *1 Shield *1 Shield *5 *3 CH4 *2 Signal source: 0 to ± 10V Signal source: 0 to ± 20mA AG For wire, use two-core shielded twisted-pair cable. Indicates the input resistance of AJ...
78 Model name AJ65VBTCU-68DAVN Digital valueAnalog outputInput/output characteristics * Accuracy (Accuracy relative to the maximum analog output value) Output range switchingOffset/gain settingMaximum conversion speedOutput short-circuit protectionAbsolute maximum outputNumber of analog output poi...
82 ● AJ65BT-68TD ● AJ65BT-64RD3 / 64RD4 Model name Measurement method Connectable platinum resistance temperature sensors Connectable thermocouples Temperature input range Temperature detection value Scaling value Overall accuracy Cold-junction compensation system (˚C) Resolution (˚C) Conversi...
84 AJ65BT-D62 AJ65BT-D62D AJ65BT-D62D-S1 Pulses from pulse generators and similar equipment can be acquired and counted. High-Speed Counter Modules Overview Overview Product description Page 86 Master/Local Remote I/O Analog High-Speed Counters Positioning HM I Repeaters RS-232 Interfaces Option Sof...
● List of Models 85 ■ All the high-speed counter modules are remote-device stations. ■ It is possible to select from three types of counter modules, depending on the output method of the external device connected to the counter modules. ■ The 1- and 2-phase pulse inputs are counted in one of the f...
86 ■ Large counting range, from 0 to 16777215 (24-bit binary). ■ External input: 5/12/24 VDC (2 to 5 mA) ■ It is possible to multiply the count value. ■ It is possible to count slow rising and falling edges without errors by switching to the slow counting speed. ■ It is possible to select four count...
88 AJ65BT-D75P2-S3 Complicated positioning control tasks can be handled by reading various signals, parameters and data, and by implementing the control loop on a PLC CPU. Positioning Module Product description Page 90 Overview Overview Master/Local Remote I/O Analog High-Speed Counters Positioning ...
89 ■ It is possible to use the positioning function equivalent to positioning modules AD75P2-S3 and A1SD75P2-S3 of the MELSEC-A Series in a CC-Link slave station. Moreover, the following functions are added: ● Home position return specified by data ● Speed/position switch control function (ABS mode)...
90 Item Specification Number of control axes Interpolation function Control method Control unit Positioning data Peripheral device /software package Teaching module Backup Positioning Positioning Positioninmethod Positioningrange Speedcommand 2 axes 2-axis linear interpolation, 2-axis circular inter...
92 ■ Example of Connection between D75P2 and MR-J2/J2S- □ A (Differential Driver (Open Collector), Negative Logic * 5 ) "AD75C20SNJ2 type cable (for differential driver)" can be used for the connection between D75P2 and MR-J2/J2S- □ A. * 1 The same connector pin numbers of D75P2 are used fo...
Overview Overview 94 Module for operating PLC CPU remotely via CC-Link Peripheral Device Connection Module AJ65BT-G4-S3 Product description Page 96 Master/Local Remote I/O Analog High-Speed Counters Positioning HM I Repeaters RS-232 Interfaces Option Software Others Technical Information C C -Lin k-...
Overview 95 ● Overview Peripheral Device Connection Module ● List of Models AJ65BT-G4-S3 Peripheral device connection modulefor the GPP function Intelligent device 1 96 Product name Model name Description Number of occupied stations Station type Related manual Page with detailed information User...
96 AJ65BT-G4-S3 Peripheral Device Connection Module ● Performance Specifications Model name Peripheral device connector Station type Number of occupied stations Allowable momentary power failure period Applicable solderless terminal Module mounting screws Applicable DIN rail 24 VDC...
99 ● Overview Communication Modules for HMI (GOT) ● List of Models CC-Link connection module for GOT-A900/800 Series CC-Link connection module for GOT-A900/800 Series A8GT-J61BT13 A8GT-J61BT15 CC-Link communication module Intelligent device Remote device User's Manual IB-66838 (13JL56) User's M...
100 A8GT-J61BT13 Communication Modules for HMI (GOT) ● Performance Specifications See page 154 for the general specifications. A8GT-J61BT13 Intelligent device station Selectable from 1 station/4 stations At one station (32 points each for RX/RY, 4 words each for RWr/RWw) At four stations (12...
104 IBM PC/AT compatible PCs can be used as master/local stations of CC-Link. PC Interface Boards PC equipped with PCI bus Local station Remote I/O station Remote device station Local station Master station PC equipped with PCI bus A80BDE-J61BT11A80BDE-J61BT13CC-Link interface board A80BDE-J61BT11CC...
105 ● Overview PC Interface Boards ● List of Models ● Operating Environment User's Manual IB-0800175 (13JR28) User's Manual (SW3DNF-CC-link compatible) IB-0800176 (13JR29) CC-Link interface board for IBM PC/AT compatible PC (master/local station for PCI bus slot) CC-Link interface board for IB...
106 PC Interface Boards ● Performance Specifications See page 154 for the general specifications. ■ A PC incorporating a PCI bus can be used as the master station, standby master station* 1 , or as a local station by mounting A80BDE-J61BT11, or as a local station by mounting A80BDE-J61BT13. ■ Wh...
108 Various repeater modules expand the range of CC-Link adaptations and enhance the freedom of application. Repeater Modules ● Overview ■ Three types (five models) of repeater module are available for use according to the desired purpose in the CC-Link network. ● Repeater (T-branch) module: AJ65S...
109 Repeater Modules ● List of Models If the module is used in this way … ? Select this! ? ! 110 112 112 110 112 114 Selection condition Page with detailed information Model name of the module that should be selected Feature of module that should be selected Selection of Repeater Modules AJ65SBT-R...
110 AJ65SBT-RPT Repeater Module ● Performance Specifications See page 154 for the general specifications. ■A T-branch configuration can be included in the CC-Link network. By placing this module between other modules in the CC-Link system, T-branches can be inclu ded in the CC-Link network ...
112 AJ65SBT-RPS AJ65SBT-RPG Repeater Module ● Performance Specifications See page 154 for the general specifications. ■ CC-Link system optical repeater module The transmission distance of the CC-Link system can be extended. It is possible to extend the transmission distance of the CC-Link sy...
● System Configuration 113 Repeater Module AJ65SBT-RPS AJ65SBT-RPG ● External Dimension Diagram ● Name and Setting of Each Part ● Module Connection Optical interface DIN rail hook Operation LED display The status of the module can be checked by the on/off status of the LED display. Transmi...
114 Repeater Module ■ Wireless transmission can be achieved by infrared light. 。 By using AJ65BT-RPI-10A and AJ65BT-RPI-10B modules combined, it becomes possible to perform wireless transmission in the CC-Link system over distances from 0 to 100 m using infrared light. This allows the use of th...
Overview Overview 118 It is possible to perform data communication with external devices, such as bar-code readers and ID controllers that communicate via RS-232, and general-purpose PCs. RS-232 Interface Module AJ65BT-R2 ● Overview ■ T he table below shows a list of external devices that can be c...
120 AJ65BT-R2 Product Description RS-232 Interface Module ● Performance Specifications See page 154 for the general specifications. Interface specification Transmission method Synchronization method Transmission speed Data format Error detection Communication control (flow con...
● Name and Setting of Each Part ● External Connection Diagram ● External Dimension Diagram 121 Product Description RS-232 Interface Module AJ65BT-R2 ● External Connection RS-232 transmission specification setting switch This is used for setting the RS-232 transmission specification. Termin...
PW L RUN L ERR. 0123456789ABCDEF CL2X16-D1M1V ST.No. 1 2 3 4 5 6 7 8 LINK/PW IN ON CL1X2-D1D3S PW L RUN 0 STA TIO N NO . 402010 8 4 2 1 HLD COMM . 1 24G X0 Y0 +24V IN OUT CL1PAD1 POWER +2 4V 24 G DBDA 24G DBDA +24V LCNET/POWER LINK A J65SBT-CLB 40 20 10 8 4 2 1 4 2 1 2 1 2 1 2 1 PW L RUN L ERR. STAT...
123 Q Series QnA Series A Series FX Series PCI Board Others Model of connectable master modules QJ61BT11N AJ61QBT11, A1SJ61QBT11 AJ61BT11, A1SJ61BT11 FX 2N -16CCL-M (※ 1 ) A80BD-J61BT11 Master module made by partner manufacturers of CC-Link ● Applicable master modules ※1 FX Series can be used in th...
● Performance Specifications See page 154 for the general specifications. ■ Seamlessly connecting two networks The AJ65SBT-CLB is a bridge module that enables seamless connection of the CC-Link and CC-Link/LT networks . Up to 224 points (448 points when using I/O) can be controlled with one ...
Overview Overview 126 Various optional parts are available for I/O modules. Optional Parts One-touch connector plug One-touch connector plug for communication Application AJ65SBTC □-□ type digital I/O moduleAJ65VBTCU □-□ type digital I/O moduleAJ65VBTCU- □ type analog I/O module Model name A6CON-P21...
● List of Models ● Wiring Method 128 One-Touch Connector Plug Optional Parts for I/O Modules A6CON-P214A6CON-P220 A6CON-P514A6CON-P520 The following are one-touch connectors for input/output. Due to the easy-to-use loose wire pressure-welding connection method (eliminating the need for solderi...
● List of Models 129 A6CON-L5PA6CON-PW5P A6CON-LJ5PA6CON-PWJ5P A6CON-TR11 The following parts are provided for AJ65VBTCU □ - □ type digital I/O modules and AJ65VBTCU- □ type analog I/O modules. Due to the use of loose wire pressure-welding connection method (eliminating the need for solder-ing, wi...
● External Dimension Diagram ● List of Models 130 Protective cover Optional Parts for I/O Modules ■ It is possible to prevent foreign substances from getting into the opening area of the terminal block. ■ The protective cover can be attached or removed when the modules are lined up next to eac...
● List of Models ● List of Models ● List of Models 131 Protective Cap for Unused Connector Areas Optional Parts for I/O Modules Dust-proof cap (a pack contains 20 pieces) Model name A6CAP-DC1 A6CAP-WP1 A6CAP-WP2 Specification Dust-proof only (not conforming to the IP67 s...
● List of Models 132 Configurator for CC-Link Software Precaution FX PLCs cannot be used. The master station parameters for the Q and QnA Series PLC CPUs must be set by GX Developer. <Sequence program when J61P is used> Set the parameters with J61P and write to E 2 PROM . <Conventiona...
● List of Models 133 MELSEC Programming Software Software ● Operating Environment OS CPU Display Memory hard disk space Disk drive Communication interface Operating environment Windows ® 95 (English version), Windows ® 98 (English version), Windows ® NT, Workstation 4.0 (English versio...
134 ● Torque outputs as high as 150 percent is achieved at a low speed and 1 Hz. ● FR-E540- □ K uses the optional FR-A5NC inverter module, which means that the inver- ters can be connected to the CC-Link. Up to 42 inverters can be connected. ● The inverters are not only able to stop operation of t...
135 ● Performance Specifications Product Description AC Servo Amplifier / Interface module MR-J2S- □ CP-S084/MR-J2S-T01 Product Description Product Description ● Web home page for MR-J2S Series MELFANS compatible with CC-Link ● Because the servo amplifier houses the positioning function, no...
136 AC Servo Amplifier ● This servo amplifier has a built-in positioning function, so a positioning controller is not required. ● The best choice for high-frequency feeding applica-tions such as press feeders, cut-sheet feeders, etc. ● It is possible to send positioning data, start and stop comman...
137 ● Performance Specifications Product Description CNC MELDAS Series Product Description Product Description Model MELDAS C6 5 16 / 80 1 / 65 − − 512 / 512 40 / 600 32000Step Machining center family Lathe family Control axis Machine interface Tape length (standard/max.) PLC/APL...
138 Industrial Robot RP, RV-A, RH-A, RV-T, RH/RC-G Series ■ With its reinforced network functionality, this robot controller can be used in various system structures. ● The 64-bit RISC processor employed in the robot al-lows for high-speed, highly accurate and complex path motions. In addition,...
140 Product Description Dedicated CC-Link Communication LSI MFP1 MFP2 MFP2A MFP3 ● List of Models Ordering model name MFP2 MFP2A A6GA-CCMFP2N 60F For remote I/O stations For remote I/O stations 100-pin QFP (Quad FLAT Package) 14x14 mm body, 0.5 mm between pins 80-pin QFP (Quad FLAT Package) 12...
141 ■ This is an interface block used to connect Mitsubishi Mi- cro-PLCs of the FX 0N , FX 1N , FX 2N, FX 1NC and FX 2NC Series to a CC-Link network as remote-device stations ● With the micro-PLC, distributed control can be made easily and economically. ● It is possible to communicate up to 112 po...
142 Breaker MDU Breaker ● Performance Specifications Measured values Number of occupied stations Load current (current value, demand value, and maximum demand value) Line voltage (current value, demand value, and maximum demand value) Power (current value, demand value, and maximum...
143 Product Description Power Measurement Module Model name Phase/wire type Rated voltage Rated current Measured values Number of occupied stations EMU-C3P5 250 A/100 A/50 A (switching) EMU-C3P5-5A 5 A (current on the first current sensor side) ■I t can ...
144 ● Performance Specifications Product Description Multi-Circuit Electric Power Measuring Module EMU-C7P4 - 6-A Product Description Product Description ■ Multi-Circuit Electric Power Measuring Module ● The current, voltage, Watt and Watt-hour of multiple low-voltage circuits are measured simu...
145 Protective Relay Control power supply External dimensions/weight Number of occupied stations C □□□ -A □□ D □ Common for 100 to 220 VDC and 100 to 220 VAC D1 module: Approx. 150 (W) x 250 (H) x 200 (D), approx. 3 kg D2 module: Approx. 300 (W) x 250 (H) x 200 (D), approx. 5 kg...
Technical Information ● Overview of CC-Link ● General Specifications/Glossary 147 Master/Local Remote I/O Analog High-Speed Counters Positioning HM I Repeaters RS-232 Interfaces Option Software Others Technical Information C C -Lin k- CC -L in k / L T B rid ge Mo du le s Support PC Interfaces Peri...
149 Overview of CC-Link T-Branch Communication Specification (When Repeater (T-Branch) Modules are not Used) Remote I/O / remote device station Remote I/O / remote device station Remote I/O / remote device station Remote I/O / remote device station Remote I/O / remote device station Remote I/O / rem...
150 Cyclic transmission Transient transmission Bit transmission Word transmission Dedicated instruction It is possible to communicate 32 input points and 32 output points of data per station. It is possible to read/write 4 points of data per station. Transient transmission to local stations and inte...
152 Differences Between Versions 1.10 and 1.00 Specification List of CC-Link Version 1.00 (Differences from Version 1.10) ■ The specifications of CC-Link Version 1.10 and Version 1.00 differ with respect to the following two subjects: ● Maximum total cable length and cable length between stations ...
153 Overview of CC-Link ■ With Ver. 2, the cyclic data size can be increased through extended cyclic setting. Differences Between Versions 2 and 1 CC-Link Ver. 1 specification Number of linked points for each occupied station number 1station occupied 2station occupied 3station occupied 4station occu...
General Specifications/Glossary Technical Information 154 * 1 : Interface boards for use in PCs depend on the PC used. * 2 : This indicates to which power-distribution area the device is connected until it reaches the mechanical device within the premises from the public distribution grid. Category ...
General Specifications/Glossary 155 ● Glossary and Definition of Abbreviations I/Omode …………………………… Intelligent mode …………………… Intelligent device station ………… Intelligent device module ………… Error invalid station setting ……… Off-line test ………………………… Station ……………………………… Number of stations ……………… Sta...
Support 157 ● Overseas Support System ● CC-Link Partner Association (CLPA) From page 158 From page 162 Master/Local Remote I/O Analog High-Speed Counters Positioning HM I Repeaters RS-232 Interfaces Option Software Others Technical Information C C -Lin k- CC -L in k / L T B rid ge Mo du le s S...
Overseas Support System Essential S for Custom through a Truly Glob 158 S u p p o r t North America FA Center Mitsubishi Electric Automation,Inc. 500 Corporate Woods Parkway Vernon Hills,IL60061 Tel 1-847-478-2100 1-847-478-2469(Japanese Account Division) Fax 1-847-478-0328 1-847-478-239...
upport ers al System 159 <PLCs, Inverters, Servos, HMIs> Overseas Support System Beijing FA Center Gangling Electronic Technology Development (Beijing) Co.,Ltd.Industrial Automation Engineering Dept. Taipei FA Center Setsuyo Enterprise Co.,Ltd. Mitsubishi Electric Taiwan Co.,Ltd. Unit 917-918,...
Overseas Support System 160 S u p p o r t ● Service Network Please consult the FA Center if you are not in Japan, just as you would consult a branch office in Japan. The branch offices in the individual areas are the key stations for domestic information, and the FA centers are the key stations fo...
161 <Robots> Overseas Support System ● Industrial Robots ● Some products must be ordered from Japan. * Some services cannot be provided, depending on area. Please inquire with Mitsubishi Electric for detailed information hereof. upport ers al System Beijing FA Center Gangling Electronic Tec...
162 Essential S for Custom through a Truly Glob North America FA Center ■ North/South America Mitsubishi Electric Automation,Inc. Chicago [MEAU (IL)] 500 Corporate Woods Parkway,Vernon Hills,Illinois 60061,USA Tel 1-847-478-2500 Fax 1-847-478-2650 Mitsubishi Electric Automation,Inc. New Jersey [MEAU...
163 upport ers al System ■ China/Hong Kong Ryoden Automation (Shanghai) Ltd.Beijing Office Beijin 9/F,Office Tower 1,Henderson Center,18 Jianguomennei Dajie, Dongcheng District,Beijing 100005 Tel 1-86-10-6518-2930 Fax 86-10-6518-2530 Ryoden Automation (Shanghai) Ltd. Shanghai 2F Block5 Building Auto...
CC-Link Partner Association (CLPA) S u p p o r t What is the CC-Link Partner Association? A conformance test is conducted for each model of all the CC-Link and CC-LinkL/T products sold by a partner manufacturer. The test ensures that it can be used safely. What Does a Conformance Test Mean? Bundle n...
165 Global Support System The CC-Link Par tner Association has set up bases, not only in Japan but also in overseas locations in order to pursue expansion in the partnership of manufacturers and ensure greater convenience for customers. South Korea North America ASEAN (Singapore) China Taiwan CC-Lin...
168 AJ61BT11 A1SJ61BT11 AJ61QBT11 A1SJ61QBT11 QJ61BT11N FX 2N -16CCL-M AJ65FBTA4-16D AJ65FBTA4-16DE AJ65SBTB1-8D AJ65SBTB1-16D AJ65SBTB1-16D1 AJ65SBTB1-32D AJ65SBTC4-16D AJ65SBTW4-16D AJ65SBTCF1-32D AJ65SBTB3-8D AJ65SBTB3-16D AJ65SBTB2N-8A AJ65SBTB2N-16A AJ65VBTCU3-8D1 AJ65VBTCU3-16D1 AJ65FBTA2-16T ...
Index of CC-Link Related Product Models 172 Index of CC-Link Related Product Models ■ Index of Models (in alphabetic order) List of Models/Index A C E F M Q R S AJ61QBT11 A1SJ61QBT11 AJ61BT11 A1SJ61BT11 AJ65SBTB □ - □ AJ65BTB □ - □ AJ65SBTC □ - □ AJ65VBTCU □ - □ AJ65MBTL1N- □ AJ65FBTA □ -16 □ AJ65SB...
CC-Link Compatible Product Catalog CC-Link Compatible Product Catalog Consumption tax is not included in the prices of all products listed in this catalog. Please be aware that consumption tax will be added to the price at the time of purchase. Precautions in Usage This company shall not be liable f...
Mitsubishi Manuals
-
Mitsubishi PKA-A18GA
User Manual
-
Mitsubishi PKA-A18GA
Installation Manual
-
Mitsubishi PKA-A18GAL
User Manual
-
Mitsubishi PKA-A18GAL
Installation Manual
-
Mitsubishi PCA-A42GA1
User Manual
-
Mitsubishi PCA-A42GA1
Installation Manual
-
Mitsubishi MSZ-FH18NA
User Manual
-
Mitsubishi MSZ-FH18NA
Installation Manual
-
Mitsubishi MSZ-D36NA
User Manual
-
Mitsubishi MSZ-D36NA
Installation Manual
-
Mitsubishi WD-82742
User Manual
-
Mitsubishi MSZ-FE09NA
User Manual
-
Mitsubishi MSZ-FE09NA
Installation Manual
-
Mitsubishi LT-46164
User Manual
-
Mitsubishi MSY-D36NA-8
User Manual
-
Mitsubishi MSY-D36NA-8
Installation Manual
-
Mitsubishi MSY-A15NA-1
User Manual
-
Mitsubishi MSY-A15NA-1
Installation Manual
-
Mitsubishi WD-73638
User Manual
-
Mitsubishi PKA-A36FA
User Manual