1A M-SERIES HIGH PERFORMANCE SYSTEMS MSZ/MUZ-FH High Efficiency Heat Pumps | 3,100–25,200 Btu/h Capacity Range Heat pumps are now a realistic option for any home, in any climate. The MSZ-FH family of Hyper-Heating INVERTER residential systems offer year-round, high-efficiency cooling and heating for...
Page 3 - OPTION 1; MUZ–FH H2i HEATING CAPACITY; MUZ–FE H2i HEATING CAPACITY; HEAT AND LOTS OF IT; exceptional heat pump performance.; TECHNOLOGY
B HEATING even when it's minus 13 degrees F outdoor ambient, producing up to 100% heating capacity at 5 degrees F. YEAR-ROUND COMFORT in extreme climates without the need for energy-consuming indoor supplemental heating devices. HOT-START TECHNOLOGY provides warmth from the start, reducing drafts. M...
Page 4 - Heat Pump
1C SINGLE-ZONE I MSZ-FH Indoor Unit I Heat Pump Model Name Indoor Unit MSZ-FH09NA MSZ-FH12NA MSZ-FH15NA Outdoor Unit MUZ-FH09NA MUZ-FH12NA MUZ-FH15NA Cooling *1 Rated Capacity Btu/h 9,000 12,000 15,000 Capacity Range Btu/h 1,700-12,000 2,500-13,600 6,450 - 19,000 Rated Total Input W 560 870 1,200 En...
Page 6 - TABLE OF CONTENTS
3 TABLE OF CONTENTS PRODUCT OVERVIEW ............................................................................................................................................... 4 PRODUCT FEATURES H2i® Technology .......................................................................................
Page 7 - PRODUCT OVERVIEW; Features
4 PRODUCT OVERVIEW Features Benefits INVERTER-DRIVEN COMPRESSORS Maximizes energy savings by using only the energy needed to perfectly cool or heat an area EASY INSTALLATION Installs quickly and easily, without the need for major construc-tion and remodeling COMPLETE ZONE CONTROL Realizes maximum co...
Page 8 - QUIETER THAN A
5 H2i ® TECHNOLOGY HEATING even when it's -13° F outdoor ambient, producing up to 100% heating capacity at 5° F for MUZ-FE09/18 and 92% capacity at 5° F for MSZ-FE12 YEAR-ROUND COMFORT in extreme climates without the need for energy-consuming indoor supplemental heating devices HOT-START TECHNOLOGY ...
Page 9 - Savings Opportunities; rated. This can mean
6 M-Series systems utilize green technologies, and are much more efficient. Homeowners never have to sacrifice comfort over worries about high-energy costs. ▶ INVERTER technology results in substantial energy and utility savings for homeowners ▶ Zone control for improved comfort and decreased energy...
Page 11 - PUT COMFORT ON CRUISE CONTROL; INVERTER TECHNOLOGY; Set Temperature; OPTION 2; Time
8 Sophisticated, electronic control systems detect any change in room or zone temperature and—like a car’s cruise control—automatically adjust the speed of the outdoor unit's INVERTER-driven compressor for precise capacity and temperature control. Electronic LEVs exactly control refrigerant flow to ...
Page 12 - healthier, breathing environment for the home.; MULTIPLE FILTERS FOR CLEANER, HEALTHIER AIR; HYBRID CATECHIN
9 Our indoor units use a sophisticated multi-part filtration system to reduce contaminants such as allergens, viruses and bacteria from the air. This combination of filters provides a healthier, breathing environment for the home. MULTIPLE FILTERS FOR CLEANER, HEALTHIER AIR HYBRID CATECHIN PRE-FILTE...
Page 13 - MHK1 WIRELESS REMOTE CONTROLLER KIT
10 Wireless Wall-Mounted Remote Controller and Wireless Receiver • Installs anywhere with simple wall-mounted design• Large, backlit, easy-to-read display• Dual set-point control with system changeover• Both controller and receiver enabled with RedLINK ™ reliability The basic MHK1 Wireless Remote Co...
Page 14 - MHK1 FEATURES
11 ™ Optional RedLINK Internet Gateway (Available through select distributors) Just connect the Gateway device (far right) to your internet router, download the free app, register a serial number with the Gateway web site and pair the system with the RedLINK ™ enabled devices of your choice. You’ll ...
Page 15 - HAND-HELD COMFORT CONTROL; CONTROLLER FEATURES INCLUDE:
12 HAND-HELD COMFORT CONTROL Mitsubishi Electric hand-held controllers can adjust temperature, fan speed, and more. CONTROLLER FEATURES INCLUDE: ▶ MODE : HEAT, COOL, AUTO, and DRY ▶ FAN : Adjusts fan speed ▶ STOP/START : A 12-hour ON/OFF timer ▶ ECONO COOL : Energy efficient cooling option ▶ VANE : ...
Page 16 - Indoor unit connecting cable: Dedicated 5-wire cable included; For Reference Approval Construction; Contr; • Room Temperature: Displays
13 MAC-333IF-E SYSTEM CONTROL INTERFACE PAC-YT53CRAU SIMPLE MA CONTROLLER PAR-31MAA BACKLIT MA REMOTE CONTROLLER • Allows M-Series indoor units to communicate with the CITY MULTI Controls Network via M-Net • Provides an input to allow remote On/Off control of indoor unit (3-Wire plug adapter include...
Page 17 - DETECT AND CONTROL TEMPERATURE FLUCTUATIONS; room temperature; scan the room and adjust airflow based on ambient
14 This amazing technology constantly monitors and adjusts temperatures for maximum comfort and efficiency.• Measures infrared radiation generated from surrounding walls and surface angles • Efficiently adjusts temperatures to ideal comfort levels for occupants Detects temperature variations and con...
Page 18 - Ratchet Flaring Tool; INSTALLATION BEST PRACTICES; Installation Tips for Maximum Efficiency—Indoors
15 Look for opportunities to use Mitsubishi Electric systems on every job! Single and Multi-zone systems for Hot and Cold Spots, Living Rooms, Bedrooms, Kitchens, Allergy Problems, Renovations, Energy Savings Opportunities, Media Rooms, Basements, Combination with Traditional System, Whole Floor, Wh...
Page 19 - Homeowner Education; In extremely cold weather, you can temporarily:
16 Homeowner Education Educate homeowners about their Mitsubishi Electric system to reduce callbacks and generate referrals: • Use the Mitsubishi Electric system as the primary heating and cooling system to maximize benefits, maintain comfort and ensure that the unit performs most efficiently. • Sec...
Page 20 - M-SERIES MULTI-ZONE PRODUCTS AND FEATURES; personalized comfort.; WALL-MOUNTED INDOOR UNITS FOR MULTI-ZONE SYSTEMS
17 Total zone control: individually controlled rooms (up to 8) with a single outdoor system M-SERIES MULTI-ZONE PRODUCTS AND FEATURES With the MXZ-B multi-zone system your customers can enjoy ideal levels of comfort in the rooms you use most while reducing their energy costs. Each zone operates inde...
Page 21 - CEILING-RECESSED INDOOR UNITS FOR MULTI-ZONE SYSTEMS; HORIZONTAL-DUCTED HEAT PUMPS FOR MULTI-ZONE SYSTEMS; FLOOR-MOUNTED INDOOR UNITS FOR MULTI-ZONE SYSTEMS
18 MSZ-FE High Efficiency Heat Pumps | 09, 12, 18 • Quiet operation as low as 22 dB(A)• Offers a wide vane for a wider angle of airflow, 150° from left to right (on FE18 models) • Motorized horizontal vanes on FE09/12/18 models• i-see Sensor ™ technology on FE09/12 models • Triple filtration system ...
Page 22 - MULTI-ZONE SYSTEM POSSIBILITIES; For a complete list of the MXZ-B Series approved combinations,
19 MULTI-ZONE SYSTEM POSSIBILITIES MXZ-8B48NA-1 (2:1, 8:1) Outdoor Unit* *Illustration purposes only. SEZ-KD09NA Indoor Unit SEZ-KD15 Indoor Unit Branch Box (Minimum of one required with MXZ-8B) Two MSZ-GE06NA Indoor Units MFZ-KA12NA Indoor Unit (Two indoor units must be installed.) MXZ-2B20NA-1 (2:...
Page 24 - M-SERIES SINGLE-ZONE PRODUCTS AND FEATURES; power of precise control over hot and cold spots.
21 SINGLE-ZONE, WALL-MOUNTED HEAT PUMPS Cooling and Heating Slim, wall-mounted indoor units provide zone comfort control. INVERTER-driven compressors and electronic LEVs provide higher efficiency with controlled power usage. The indoor unit is powered by the outdoor unit and should a power outage oc...
Page 25 - Use commercial grade P-Series with full cooling capacity down to 0; Cooling Only; SINGLE-ZONE PRODUCTS
22 SINGLE-ZONE, HORIZONTAL-DUCTED HEAT PUMPS Cooling and Heating SEZ ducted units provide comfort and efficiency while staying hidden either in the ceiling or beneath the floor. All 1:1 systems are ENERGY STAR ® certified. SEZ/SUZ Heat Pumps | 3,800–19,000 Btu/h Capacity Range • 15–17.5 SEER, 10 HSP...
Page 27 - DIAMONDBACKTM BV-SERIES BALL VALVES; BALL VALVES; DIAMONDBACK PLATFORM STANDS; FILTER BOXES
24 DIAMONDBACK™ BV-SERIES BALL VALVES Diamondback BV-Series ball valves include the following features: • Engineered for mini-split and multi-split HVAC units • Full port design with flare connections • 700 PSIG rated • Flare connections Other important information: • Size available: 1/4", 3/8...
Page 28 - LINESETS; DIAMONDBACK LINESETS
25 “TWIN-TUBE” LINESET INSULATION DESIGN • Balanced outside diameter for uniform coil/uncoil position stability. • Minimum 1/2” insulation thickness on both tubes • Meets UL94 and ASTM E84 Standard Caps On LINESETS DIAMONDBACK LINESETS Diamondback linesets include the following features: • Quick, ef...
Page 31 - MS Indoor Unit
28 SINGLE-ZONE I MS Indoor Unit NON-INVERTER Model Name Indoor Unit MS-A09WA MS-A12WA Outdoor Unit MU-A09WA MU-A12WA Cooling *1 Rated Capacity Btu/h 9,500 12,000 Capacity Range Btu/h - - Total Input W 870 1,070 Energy Efficiency SEER 13 Moisture Removal Pints/h 2.7 3.2 Sensible Heat Factor 0.68 0.70...
Page 33 - MSZ Indoor Unit
30 $ $ $ $ $ Model Name Indoor Unit MSZ-FE09NA-8 MSZ-FE12NA-8 MSZ-FE18NA MSZ-GE09NA-8 MSZ-GE12NA-8 Outdoor Unit MUZ-FE09NA-1 MUZ-FE12NA1 MUZ-FE18NA MUZ-GE09NA MUZ-GE12NA Cooling *1 Rated Capacity Btu/h 9,000 12,000 18,000 9,000 12,000 Capacity Range Btu/h 2,800-9,000 2,800-12,000 8,200-25,200 3,800-...
Page 35 - SEZ Indoor Unit
32 Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4 Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA Cooling *1 Rated Capacity Btu/h 8,100 11,500 14,100 17,200 Capacity Range Btu/h 3,800-10,900 3,800-13,300 3,800-17,000 3,800-19,000 Total Input W 670 920 1,170 1,380 Ene...
Page 36 - SEZ Static Performance Curves
33 SEZ Static Performance Curves INDOOR FAN PERFORMANCE AND CORRECTED AIR FLOW SEZ-KD09NA4 (External static pressure 0.06[in.WG]) 208/230V 60Hz 0 Airflow rate [CFM] [141] [176] [212] [247] [282] [318] [353] External static pressure [in.WG] [0.20] [0.16] [0.12] [0.08] [0.04] Middle Low High Limit Rat...
Page 37 - SLZ Indoor Unit
34 Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Cooling *1 Rated Capacity Btu/h 8,400 11,100 15,000 Capacity Range Btu/h 3,100-10,900 3,400-13,300 3,800-17,700 Total Input W 700 920 1,460 Energy Efficiency SEER 15 15.4 16 Moisture Removal Pint...
Page 40 - MSZ Indoor Units
37 Model Name Indoor Unit MSZ- FE09NA-8 MSZ- FE12NA-8 MSZ-FE18NA MSZ- GE06NA-8 MSZ- GE09NA-8 MSZ- GE12NA-8 MSZ- GE15NA-8 MSZ- GE18NA-8 MSZ-GE24NA Cooling *1 Rated Capacity Btu/h 9,000 12,000 18,000 6,000 9,000 12,000 14,000 17,200 22,500 Heating at 47° F *2 Rated Capacity Btu/h 10,900 13,600 21,600 ...
Page 41 - SEZ Ducted Indoor Unit
38 Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4 Cooling *1 Rated Capacity Btu/h 8,100 11,500 14,100 17,200 Heating at 47˚ F *2 Rated Capacity Btu/h 10,900 13,600 18,000 21,600 Power Supply Phase, Cycle, Voltage 1-Phase, 60Hz, 208 / 230V *4 Voltage Indoor - Outdoor S1-S2 AC ...
Page 43 - SLZ Ceiling-recessed Indoor Unit
40 Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA Cooling *1 Rated Capacity Btu/h 8,400 11,100 15,000 Heating at 47° F *2 Rated Capacity Btu/h 10,900 13,600 18,000 Power Supply Phase, Cycle, Voltage 1-phase, 60Hz, 208 / 230V *3 Voltage Indoor - Outdoor S1 - S2 AC 208 / 230V Indoor - Outdoor...
Page 44 - ADDITIONAL M-SERIES INFORMATION; MULTI-ZONE EFFICIENCY RATINGS
41 M-SERIES OPER ATING CONDITIONS INDOOR INTAKE AIR TEMPERATURE OUTDOOR INTAKE AIR TEMPERATURE COOLING MAXIMUM 95° F D.B., 71° F W.B. (MU; SUZ; MXZ-2B20/3B24/3B30/ 4B36-1,5B42) 90° F D.B., 73° F W.B. (MUZ/Y-GE; MUZ-FE; MUZ/Y-D) 115° F D.B. (MU; MUZ/Y-GE; MUZ/Y-D; MUZ-FE; SUZ; MXZ-2B20/3B24/3B30/4B36...
Page 45 - PORT ADAPTER GUIDE; PORT ADAPTERS PART NUMBERS; How to Read a Model Number
42 PORT ADAPTER GUIDE AVAILABLE INDOOR UNITS LINE SET SIZE MSZ Wall-mounted MSZ-GE06NA-8 3/8" gas x 1/4" liquid MSZ-GE09NA-8 3/8" gas x 1/4" liquid MSZ-FE09NA-8 3/8" gas x 1/4" liquid MSZ-GE12NA-8 3/8" gas x 1/4" liquid MSZ-FE12NA-8 3/8" gas x 1/4" liquid MSZ-...
Page 46 - COOLING CAPACITY CORRECTION FACTORS
43 MODEL MODE FUNCTION AIRFLOW (CFM) COVERAGE (FT) MS-A09WA FAN DRY 335 25.4 COOL WET 300 22.8 MS-A12WA FAN DRY 406 30.6 COOL WET 363 27.5 MSZ-GE06NA-8 MSY-GE09NA-8 MSZ-GE09NA-8 MSY-GE12NA-8 MSZ-GE12NA-8 HEAT DRY 406 29.5 COOL WET 286 21.0 MSY-GE15NA-8 MSZ-GE15NA-8 HEAT DRY 463 33.5 COOL WET 385 28....