Page 3 - Advanced Technology.; M-Series components are up to; before
Advanced Technology. Superior Comfort. Split-zoning is the most popular type of air-conditioning technology in the world. Mitsubishi Electric takes split-zoning to a new level—our cooling and heating systems deliver year-round personal comfort even in the harshest of climates. Mitsubishi Electric si...
Page 4 - ENERGY STAR; M-Series Qualifying Models; EnErgy
Mitsubishi Electric systems are now more environmentally friendly than ever! Use them to earn any available state, municipal, and utility rebates. ENERGY STAR ® M-Series Qualifying Models * EnErgy Star MUY-GE09NA w/ MSY-GE09NA-8 3 MUY-GE12NA w/ MSY-GE12NA-8 3 MUY-GE15NA-1 w/ MSY-GE15NA-8 3 MUY-GE24N...
Page 5 - Get the free mobile app at; P-Series Qualifying Models
For tax credit details and forms, visit www.mitsubishicomfort.com/taxcredit For details on state and utility rebates, visit www.dsireusa.org Get the free mobile app at ht t p:/ / get t ag.mobi Use your smart phone to scan the tag to the left and go to the page. Get the free app for your smart phone ...
Page 6 - How to Read a Model Number
M-Series (9,000 - 48,000 Btu/h) 1. For residential and light commercial buildings (including conference rooms and storage areas) 2. User-friendly cooling and heating solutions for single-room and multi-room applications 3. H2i (hyper-heating INVERTER) outdoor units can provide high heating at lower ...
Page 7 - P k
P-Series (12,000 - 42,000 Btu/h) 1. For commercial, industrial, institutional, and large residential buildings - ideal in areas requiring year-round, low ambient cooling such as computer, elevator and equipment rooms 2. H2i (Hyper Heating Inverter) outdoor units can provide high heating at lower amb...
Page 8 - D Models; Cooling-only and heat pump models; Our standard line is now greener than ever!; Eight ENERGY STAR
D Models (30,700 - 34,600 Btu/h) ▶ Wide vane mode for precise directional airflow (also available on MSY/Z-GE24NA & MSZ-FE18NA) ▶ Powerful mode for quick 15 minute heating/cooling boost (also available on MSY/Z-GE24NA and MSZ-FE18NA) ▶ Cooling-only and heat pump models Our standard line is now g...
Page 9 - FE Models; Three ENERGY STAR; MFZ Models; For use with MXZ multi-zone outdoor units only
High-efficiency, Hyper-Heating systems FE Models ▶ Three ENERGY STAR ® models ▶ i-see™ sensor automatically adjusts comfort conditioning by sensing temperature variations in the room and adjusting vane direction (MSZ-FE09 and MSZ-FE12 models only) ▶ 100% heating capacity at 5º F on MSZ-FE09NA and MS...
Page 10 - SEZ Models
select systems SEZ Models ▶ Small compact design (7-7/8" height) ▶ Adjustable static pressure ▶ Built-in condensate lift mechanism (22-1/2" lift) ▶ Rear return or bottom return (with optional accessory) ▶ Low operating sound pressure levels; as low as 23 dB(A) ▶ All four models ENERGY STAR ®...
Page 11 - Multi-Zone Heat Lineup; O u t d o o r U n i t s :; P E a D - a 2 4 a a 4
M-Series Models Multi-Zone Heat Lineup MXZ Multi-Zone Heat Pumps 2:1, 3:1, 4:1, and 8:1 Zoned Solutions (20,000-48,000 Btu/h) ▶ Three combinations qualify for ENERGY STAR ® ▶ Precise, individual room comfort control ▶ Multiple indoor air handler options (ductless and ducted) ▶ Minimum of two indoor ...
Page 12 - OUTDOOR UNIT; INDOOR UNITS; D i a m o n d C o m f o r t M X Z M u l t i - z o n e S y s t e m s
SEZ HORIZONTAL-DUCTED INDOOR UNITS SEZ-KD 09 - 18 NA4 Models MXZ-8B 4 8NA OUTDOOR UNIT MFZ FLOOR-MOUNTED INDOOR UNITS MFZ-KA 09 - 18 NA Models (for use with MXZ-B units only) M-Series Models D i a m o n d C o m f o r t M X Z M u l t i - z o n e S y s t e m s 10
Page 14 - M-Series Cooling Only
MS/MSY Model Specifications (air conditioners) * Use ICM-326HM-1 Head Pressure Controller accessory for non-InVErtEr Models (for low outdoor ambient cooling only). *non-InVErtEr Models Indoor Model # *MS-a09Wa *MS-a12Wa MSy-gE09na-8 MSy-gE12na-8 MSy-gE15na-8 MSy-gE18na-8 MSy-gE24na MSy-D30na-8 MSy-D...
Page 16 - Model Specifications; SEEr; test conditions are based on aHrI 210/240.
M-Series Heat Pumps MSZ/MUZ Model Specifications (heat pumps) Indoor Model # MSZ-FE09na-8 MSZ-FE12na-8 MSZ-FE18na MSZ-gE09na-8 MSZ- gE12na-8 MSZ- gE15na-8 MSZ- gE18na-8 MSZ-gE24na MSZ- D30na-8 MSZ- D36na-8 Outdoor Model # MUZ-FE09na-1 MUZ-FE12na1 MUZ-FE18na MUZ-gE09na MUZ-gE12na MUZ- gE15na-1 MUZ- g...
Page 18 - SEZ/SLZ Models Specifications
SUZ-Ka15na SEZ/SLZ Models Specifications (heat pumps) SEZ-KD15na4 Indoor Model # SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4 SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA Outdoor Model # SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Cooling Capacity (Btu/h) 8,100 11,500 1...
Page 20 - rated Cooling
See page 3 for ENERGY STAR ® qualifying combinations. Refer to submittal document for combination performance. * 49' applies when outdoor unit is installed below indoor unit. ** 66' applies when outdoor unit is installed below indoor unit. MXZ Series MXZ Model Specifications (multi-zone heat pumps) ...
Page 21 - SEE PAGE 20 FOR INDOOR; Each MXZ-8B48NA requires
See section 5 of installation manual for full details on MXZ-8B48NA refrigeration piping lengths. MXZ-8B48na BranCH BOX FOr InDOOr UnIt COnnECtIOnS SEE PAGE 20 FOR INDOOR UNIT CONNECTION CAPABILITIES Each MXZ-8B48NA requires at least one branch box with a maximum of two. Two sizes are available: 3-b...
Page 22 - MXZ-Series Port Adapters; PORT ADAPTER GUIDE; PCA Ceiling-suspended
MXZ-Series Port Adapters PORT ADAPTER GUIDE Available Indoor Units Line set size MSZ Wall-mounted MSZ-GE06NA-8 3/8" gas x 1/4" liquid MSZ-GE09NA-8 3/8" gas x 1/4" liquid MSZ-FE09NA-8 3/8" gas x 1/4" liquid MSZ-GE12NA-8 3/8" gas x 1/4" liquid MSZ-FE12NA-8 3/8" gas ...
Page 24 - Cooling Capacity Correction Factors; M-Series Correction Factors
Cooling Capacity Correction Factors Model Refrigerant piping length (one way) 25 ft (std) 40 ft 65 ft MU-a09WaMU-a12WaMUZ-gE09naMUy-gE09naMUZ-gE12naMUy-gE12naMUZ-gE15na-1MUy-gE15na-1 MUZ-FE09na-1MUZ-FE12na1SUZ-Ka09naSUZ-Ka12na SUZ-Ka15na Capacity x 1.0 Capacity x 0.954 Capacity x 0.878 Model Refrige...
Page 26 - US; BV-Series Ball Valves
▶ Sizes available: 1/4 " ; 3/8 " ; 1/2 " ; 5/8 ". ▶ Fully assembled from the factory ▶ Furnace brazed and pressure tested. ▶ Each ball valve is equipped with a Schrader Valve for refrigerant service. ▶ Design working pressure: 700 PSIG. ▶ Temperature range: -40˚ F to +325˚ F (-40˚ C ...
Page 28 - Remote Controller Kit; MRCH1 Wireless Remote Controller; Compatible with MCCH1 Portable Central Controller; MIFH1 Wireless Receiver; Required for MRCH1 Wireless Remote Controller; Exclusive for INVERTER-driven
Controllers MHk1 Wireless Remote Controller Kit TM MRCH1 Wireless Remote Controller ▶ Backlit, easy-to-read display ▶ Compatible with MCCH1 Portable Central Controller ▶ Enabled with RedLINK™ reliability MIFH1 Wireless Receiver ▶ Required for MRCH1 Wireless Remote Controller ▶ Dual set-point control...
Page 29 - Controllers; Specifications
Controllers MHk1 Specifications Function Description ON/OFF On/Off operation for a single indoor unit Operation Mode Cool / Drying / Auto / Heat / Fan onlyAvailable operation modes dependent upon connected system. Temperature Setting Set temperature from 50° F – 87° F depending on operation mode and...
Page 30 - Wireless; Powerful Mode and
Wireless Standard for M-Series wall-mounted and floor-mounted systems and optional for P-Series indoor units Vane Control HR/MIN (Time Set) Timer Fan Speed Operation Select (Heat, Cool, Auto, Dry) Reset Clock Set Sliding Cover Econo Cool Smart Set Button Powerful Mode and Wide Vane Control buttons a...
Page 31 - GE model remote; Wired; Wired Controller; PAR-21MAA Wired Controller
GE model remote shown, models vary Mode Set Time Timer Menu On/Off Fan Speed FilterTest Run Check Set Temperature Airflow Up/DownLouver Ventilation Timer On/Off Wired Optional, wired controller for all M-Series INVERTER indoor units. M-Series wall-mounted and floor-mounted systems require MAC-397IF ...
Page 32 - PKA Wall-mounted Series; PCA Ceiling-suspended Series; Cooling-only and Heat Pumps; P-Series Indoor Models
PKA Wall-mounted Series Cooling-only and Heat Pumps 12,000 to 34,200 Btu/h ▶ Provides cooling and heating in a wide range of capacities ▶ Auto flap shutter ▶ Auto fan control ▶ Easy-clean washable filters ▶ Multiple controller options PCA Ceiling-suspended Series Cooling-only and Heat Pumps 24,000 t...
Page 33 - PLA Ceiling-recessed Series; PEA/PEAD Horizontal Ducted Series
PLA Ceiling-recessed Series Cooling-only and Heat Pumps 12,000 to 42,000 Btu/h ▶ Built-in condensate lift mechanism (33" lift) ▶ Branch duct outlet ▶ i-see™ Sensor optional ▶ Knockout for ventilation air ▶ Multiple controller options PEA/PEAD Horizontal Ducted Series Cooling-only and Heat Pumps ...
Page 36 - BS= Seacoast Protection Coating
BS= Seacoast Protection Coating P-Series models 12k-36k Btu/h are pre-charged for up to a 70' line set. PUY/Z-A42NHA and H2i models are pre-charged for up to a 100' line set. Indoor Model # PEa-a18aa4 PKa-a18Ha4 PLa-a18Ba4 PEaD-a24aa4 PKa-a24Ka4 PLa-a24Ba4 PCa-a24Ka4 PEaD-a30aa4 PKa-a30Ka4 PLa-a30Ba...
Page 38 - Cooling Capacity Correction Factor; Outdoor Unit; Heating Capacity Correction Factors; Outdoor Unit
Cooling Capacity Correction Factor (x capacity) Outdoor Unit refrigerant piping length (one way) 16 ft 33 ft 70 ft 100 ft 130 ft 165 ft PUy-a12/18nHa4 PUZ-a18nHa4 1.00 0.985 0.967 0.931 – – PUy-a24-36nHa4 PUZ-a24-36nHa4 1.00 0.988 0.966 0.946 0.929 0.913 PUy-a42nHa4 PUZ-a42nHa4 1.00 0.985 0.967 0.93...
Page 40 - Outlet Air Speed and Coverage Range*; *air coverage represents the distance with 0.8 ft/sec air speed when; P-Series Air Coverage Range
Model Air Flow (CFM) Air Speed (ft/sec) Coverage Range (ft) PLa-a12Ba4 530 8.5 13 PLa-a18Ba4 640 10.5 15 PLa-a24Ba4 640 10.5 15 PLa-a30Ba4 740 12.1 18 PLa-a36Ba4 1060 17.4 26 PLa-a42Ba4 1090 17.7 26 PKa-a12Ha4 425 20.0 35 PKa-a18Ha4 425 20.0 35 PKa-a24Ka4 775 19.7 47 PKa-a30Ka4 775 19.7 47 PKa-a36Ka...
Page 41 - Installation
Required Tools for Installation • Phillips screwdriver• Pipe cutter with reamer• Level• Flaring tool• Scale• Nitrogen• Utility knife or scissors• Vacuum pump • Micron gauge• 3" (75mm) hole saw• Charge hose for R410A• 1/4"-5/8" torque wrench• Gauge manifold for R410A• 5/32" (4mm) hexa...
Page 42 - Check installation instructions for your exact model.
2-7/8" or more/ 4" or more for left & left back piping using spacer 20" or more Note: Do not obstruct air outlet 4" or more 14" or more 20" or more 5' or more from floor to bottom of unit 4-3/4" or more 7-7/8" or more 4" or more Applies to all M-Series models ...
Page 43 - Minimum installation space for outdoor unit; *1 In a place where short cycling can occur, cooling; P-Series Outdoor System Clearances
To illustrate the space required around the outdoor unit, the required clearances for all P-Series models are shown below. See installation manual for the exact minimum clearances achievable for your model. 5-29/32" or more 2 sides should be open inthe right, left and rear side. 3-15/16" or ...
Page 44 - Installing Refrigerant Piping; e 3 ft; Refrigerant Piping
Max. length, PUY/PUZ-A24/36NHA systems: a1 + a2 + b 165 ft Max. length, PUZ-HA36NHA hyper-heating systems: a1 + a2 + b 245 ft >= =< >= =< Installing Refrigerant Piping For “Twinning" indoor units for better airflow coverage in a large or L-shaped room (For A24/A36, and HA36 outdoor u...
Page 45 - How to Check for Refrigerant Restriction:
1. Verify the refrigerant charge. • Remove the charge and weigh it back in. • Make sure the system has the refrigerant amount specified for the line length (see Service Manual). 2. Measure for temperature differences across evaporator. • Set unit operation to cooling and change temperature set point...
Page 47 - INDOOR UNIT
*TAZ-MS303 12-24V DC 208/230V AC Power Supply 208/230V AC A E F F D C B L1L2 12 12 GR S1S2S3 S1S2S3 S1S2S3 ** ** ** ** ** ** “Twinning" Operation S1 S2 S3 L1L2 Terminal Block Ground Terminal *TAZ-MS303 3 Pole Disconnect Ground Terminal INDOOR UNIT OUTDOOR UNIT DC Control Circuit 12-24V DC 208/23...
Page 48 - Test Run; To stop operation, press the emergency operation; Checking the Remote (Infrared) Signal Reception; Press the ON/OFF button on the remote controller and
Test Run 1. Turn power on to outdoor unit. 2. Press the emergency operation button once. The test will run for 30 minutes. If the LED light blinks every 0.5 seconds, verify the indoor/outdoor connecting wire is installed properly. After the test run, the emergency COOL mode (75°F) will operate. 3. T...
Page 49 - FYI
Need help when you are on the jobsite? Check out www.mylinkdrive.comHere you can find: service bulletins, FAQs, Guide Specs, Install Manuals, MSDS sheets, Operation Manuals, Parts Lists, Service Manuals, Submittals, Accessories and the M&P troubleshooter Auto Restart Function: Mitsubishi Electri...
Page 50 - Ducting Considerations
Ducting Considerations Ducting Considerations for the PEA/PEAD/SEZ Horizontal Ducted Indoor Unit With the introduction of ducted indoor unit products, some information on duct selection and design seems appropriate. Considering the performance and design of these indoor units, selection and proper d...
Page 51 - warranty on parts and a seven-year warranty on the compressor; LIMITED WARRANTY INFORMATION
EffEctivE July 4, 2009 All Mitsubishi Electric Split Air-conditioners and Heat pumps are covered by a limited Warranty, which includes a five-year warranty on parts and a seven-year warranty on the compressor (7 & 7 Warranty reserved for Mitsubishi Electric Diamond Contractors) . Equipment must ...
Page 52 - Specifications subject to change without notice.
Mitsubishi Electric, Mr. Slim, H2i and the three diamond logo are registered trademarks of Mitsubishi Electric Corporation. Hyper-heating technology is a pending patent of Mitsubishi Electric Corporation. RedLINK and RedLINK wireless technology logos are registered trademarks of Honeywell Internatio...