Page 2 - TABLE OF CONTENTS; LIMITED WARRANTY
TABLE OF CONTENTS SAFETY INSTRUCTIONS ● Warning Labels 2-3 4 TOTAL WATTAGE, VOLTAGE AND INSTALLATION 5 FEATURES AND CONTROLS 6-7 PORTABILITY KIT INSTALLATION 8 BEFORE OPERATION 9 OPERATING THE GENERATOR 10 MAINTENANCE ● Maintenance Schedule ● “ How-To” Maintenance 11-12 STORAGE 12 TROUBLE SHOOTING 1...
Page 3 - SAFETY INSTRUCTIONS
DANGER WARNING CAUTION DANGER indicates a potentially hazardous situation which, if not avoided, WILL result in death or serious injury. WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a potentially hazardous situa...
Page 4 - CAUTION; NOTICE
- 3 - CAUTION Improper treatment can damage the unit and shorten its life To prevent surging that may possibly damage the equipment, do not allow engine to run out of fuel when electrical loads are applied. Do not stick anything through ventilating slots, even when the generator is not operating. Th...
Page 6 - TOTAL WATTAGE, VOLTAGE AND INSTALLATION; TOTAL WATTAGE
TOTAL WATTAGE, VOLTAGE AND INSTALLATION - 5 - In order to prevent overloading and possible damage to your generator it is necessary to know the total wattage of the connected load. To determine which tools and/or appliances your generator will run follow these steps: 1. Determine if you want to run ...
Page 7 - FEATURES AND CONTROLS; Muffler
FEATURES AND CONTROLS - 6 - 10a 1. Fuel Tank Cap 2. Fuel Tank 3. Fuel Gauge (optional) 4. Fuel Tank Breathing Valve 5. Engine Choke Lever 6. Fuel Shut-off 7. Air Filter 8. Recoil Starter 9. Oil Gauge 10. Engine Shut-off 10a. Hour Meter (Only for MBG5500/7000/ MBG7000X) 11. 120 V, 20 Ampere Duplex Rece...
Page 8 - NOTE; AC Protector and Circuit Breaker (12 and 13); California
- 7 - This is a system to control gasoline evaporation. Do not remove the hose, breathing valve and carbon canister when there is fuel in the fuel tank NOTE AC Protector and Circuit Breaker (12 and 13) Your generator is protected by an AC protector (expect MBG3500) and circuit breaker. If the genera...
Page 9 - PORTABILITY KIT INSTALLATION
PORTABILITY KIT INSTALLATION - 8 - NUT, FLANGE M8 BRACKET, FOOT RUBBER FOOT BOLT, FLANGE M8×25 NUT, FLANGE M8 BOLT, FLANGE M8×16 AXIAL, WHEEL PIN Ф3.2 GASKET Ф27xФ16.5 WHEEL, 10" BOLT, FLANGE M8×55 HANDEL CUSHION, HANDEL NUT, FLANGE M8 GASKET, NYLON Φ8 Step 1 Step 3 Step 4 Step 2
Page 10 - BEFORE OPERATION
BEFORE OPERATION - 9 - Use class SE oil or a higher grade according to the table below. SAE 10W-30 or 10W-40 is recommended for general, all temperature use. Check Engine Oil CHECK AIR CLEANER TO MAKE SUR IT IS CLEAN WARNING DO NOT attempt to start this engine without filling the crank case with the ...
Page 11 - OPERATING THE GENERATOR; Start the Generator
OPERATING THE GENERATOR - 10 - Start the Generator Stop the Generator WARNING To avoid accidently hurting people nearby when pulling the starter handle, Please keep bystanders, especially children and pets, away. CAUTION Do not allow the starter handle to snap back against the engine. Return it gent...
Page 12 - MAINTENANCE; Maintenance Schedule; el
MAINTENANCE - 11 - 1. Maintenance Schedule CAUTION To prevent accidental starting, always remove the spark plug or cable from the spark plug before maintaining the generator or engine. ITEM REMARKS DAILY Before Opera ti on INITIAL 25HR EVERY 50HR EVERY 100HR Spar k Pl ug C h ec k condi ti on adj u s...
Page 13 - Clean Air Filter; STORAGE
- 12 - 2. “How-To” Maintenance Engine Oil Change Clean Spark Plug Clean Carbon Brush 1. Drain oil by removing the drain plug and the oil gauge while engine is warm. 2. Reinstall the drain plug and fill the engine with oil until it reaches the upper level on the oil filler cap. 3. Clean the oil on the ...
Page 14 - TROUBLE SHOOTING; ti
- 13 - NOTE TROUBLE SHOOTING Condi ti on Cause Correc ti ve Ac ti on Engine won't start Low engine output Engine runs erra ti cally Insu ffi cient compression Loose spark plug Tighten plug properly Loose cylinder head bolt Tighten bolt properly Damaged gasket Replace gasket Su ffi cient compression No f...
Page 15 - SPECIFICATION
- 14 - SPECIFICATION (※) rated 6000W for Canadian model in accordance with CSA regulations. MODEL NO. MBG1200 MBG3500 MBG5500 Alternator Type / Vol tage regul a ti on: Brus h/AVR Brus h/AVR Brus h/AVR Frequency: 60 Hz 60 Hz 60 Hz Vol tage: 120 V 120/240 V 120/240 V Rated Wa tt s : 1000 W 2800 W 5000...
Page 16 - Service Information; Brilliant Group Industry Inc.
LIMITED WARRANTY This Mitsubishi engine product carries a guarantee of 24 months. If your product develops a fault within this period, DO NOT return to store, you should, in the first instance contact our customer service. We welcome warranty repairs and apologize to you for being inconvenienced. Any...