Page 3 - High performance; Commercial
42 High performanceHigh EfficiencyFlexibility of installation Employment of DC twin rotary compressor has enabled to utilize a high-speed range of up to 120 rps at the maximum to secure the required capacity. Optimum compressor control has been realized by employing the vector control and the starti...
Page 4 - Flexibility of installation; High Effi ciency
-15 °C WB -15 °C DB Heating Cooling +24 °C WB +43 °C DB -15 °C 43 Compact high efficiency heat exchanger Flexibility of installation All models of this range can be installed with increased distances between the indoor and the outdoor units. The 8 and 10 HP models can be installed with refrigerant p...
Page 8 - Ducted medium
FDUM 100~140V FDUM 71V 47 Ducted air-conditioning unit available in 4 power capacities (7,1~14,0 kW )Energy class A, both in heating and in cooling (7,1 and 10,0 kW models)Extremely high splitting distance: 50 mUltra-compact design: only 29,9 cm height (7,1 kW model)Operating range, in heating and c...
Page 9 - Ducted high
FDU 71~140V FDU 200~250V 48 Ducted high Ducted air-conditioning unit available in 6 power capacities (7,10~25,00 kW )Return air intake from rear or from belowDucted high static pressure 200 PaStandard condensate drain pump with 60 cm head (7,1~14,0 kW )Compact dimensions: height only 29,5 cm (FDU 71...
Page 11 - Ceiling suspended
FDEN 71~140V 50 Ceiling suspended FDEN 71V FDC 71VN FDEN 100VA FDC 100VN FDEN 125V FDC 125VN FDEN 140V FDC 140VN FDEN 100V FDC 100VS FDEN 125V FDC 125VS FDEN 140V FDC 140VS Power supply 1 Phase 220~240V 50Hz 3 Phase 380~415V 50Hz Cooling capacity kW 7,1 (3,2~8,0) 10,0 (4,0~11,2) 12,5 (5,0~14,0) 14,0...
Page 13 - Combinations
52 Combinations Model kW 4,00 5,00 6,00 7,10 10,00 12,50 4-ways Cassette 84x84 FDT 4-ways Cassette 60x60 FDTC Ducted medium FDUM Ceiling suspended FDEN Wall-mounted SRK* Outdoor units FDC 71VN FDC 100VN FDC 100VS FDC 125VNFDC 125 VS FDC 140VN FDC 140VS FDC 200VS FDC 250VS Twin 40+40 50+50 60+60 71+7...
Page 14 - Conter V Multi system
53 In this system the combined units can be different model and different capacity. Applicable indoor units Conter V Multi system Model kW 4,00 5,00 6,00 7,10 10,00 12,50 4-ways Cassette 84x84 FDT Ceiling suspended FDEN Outdoor units FDC 71VN FDC 100VN FDC 100VS FDC 125VNFDC 125 VS FDC 140VN FDC 140...
Page 15 - Application of indoor units of the same
40+40 40+40 40+40 FDC 71VN kW 7,10 7,10 7,10 kW 1,85 1,91 1,74 3,84 3,72 4,08 kW 8,00 8,00 8,00 kW 1,99 2,08 1,84 4,02 3,85 4,35 dB(A) 30 35 37 50+50 50+50 50+50 50+50 50+50 FDC 100VN FDC 100VS kW 10,00 10,00 10,00 10,00 10,00 kW 2,94 2,84 3,12 2,78 2,72 3,40 3,52 3,21 3,60 3,68 kW 11,20 11,20 11,20...
Page 16 - model in a Conter Twin, Triple and Double Twin system
40+40 40+40 40+40 FDC 71VN kW 7,10 7,10 7,10 kW 1,85 1,91 1,74 3,84 3,72 4,08 kW 8,00 8,00 8,00 kW 1,99 2,08 1,84 4,02 3,85 4,35 dB(A) 30 35 37 50+50 50+50 50+50 50+50 50+50 FDC 100VN FDC 100VS kW 10,00 10,00 10,00 10,00 10,00 kW 2,94 2,84 3,12 2,78 2,72 3,40 3,52 3,21 3,60 3,68 kW 11,20 11,20 11,20...
Page 18 - Individual controls; Superlink II
57 Individual controls Individual controls Standard infrared control (see specifications for every single unit) Wired remote control RC-E1R/RC-E3 (optional) Simple wired remote control RCH-E3 (optional) Infrared control RCN-E1R (optional) Infrared receiver KIT RCN-KIT3-E (optional) Infrared receiver...
Page 19 - Standard infrared controls
58 • Automatic sanitization against moulds • Sleep function• Manual setting of bi-directional louver swing • Programmed 3D Auto air flow• Manual setting of CLEAN function of the anti-allergenic filter • Automatic sanitization against moulds • Sleep function• Manual setting of bi-directional louver s...
Page 20 - Wired remote control with LCD display; Optional controls
RC-E1R*/RC-E3 59 Wired remote control with LCD display Wired remote control with LCD display: the large display area and the clear LCD enables convenient access to operation and service data. • Standard weekly timer (RC-E3)• Room temperature sensor• Settable temperature ranges• Data saving function•...
Page 23 - Superlink II - Controls; Central controller
SC-SL1N-E SC-SL2N-E SC-SL3N-AE/BE 62 Superlink II - Controls Central controller SC-SL 1N-E central controller is connected to the Superlink II network via 2-core non-polar wires. It monitors and controls the on/off function of up to 16 indoor units. The unit numbers in operation or in need of servic...
Page 25 - Interface; optional kit
64 Superlink II SC-ADN-E Interface This interface enables the connection of the Superlink II network to oudoor units, so to be in a position to manage them via a SC-SL2N-E device and other centralized controls.Functions:• transmission of information of Superlink II bus data with addressing of the co...