FDC-HKXR 936 CONTENTS 20.1 GENERAL INFORMATION ...................................................................... 937 20.1.1 Specific features ............................................................................... 937 20.1.2 How to read the model name ......................................
FDC-HKXR 937 20.1 GENERAL INFORMATION 20.1.1 Specific features (1) Fuzzy control (a) Response speed and stability are enhanced. • The system automatically controls changes of return air temperature, set temperature and room temperature according to the fuzzy control. • The system response speed, can...
FDC-HKXR 938 (5) Cooling opetation down to -5˚C outdoor temperature (6) Indoor units are available with 9 capacities, in 9 types and 54 models. ● 9 capacities…22(0.8 HP), 28(1 HP), 36(1.25 HP), 45(1.6 HP), 56(22 HP), 71(2.5 HP), 90(3.2 HP), 112(4 HP) and 140(5 HP). ● 9 types…Ceiling recessed type(FD...
FDC-HKXR 939 20.1.2 How to read the model name Example: FDC P 2001 H KXR E 2 CE marking model Application power source...See the specifications Multi KXR series Heat pump type Nominal capacity R407C models Model name Indoor unit : FDT, FDTW, FDTS, FDR, FDUM FDE, FDK, FDFL, FDFU Outdoor unit : FDC 20...
963 FDC-HKXR (3) Operation chart Since the Multi KXR series air conditioner units are free multitype to which the indoor units of different capacity and different model can be combined, the operation characteristics of all combinations are very complicated, therefore only the individual operation ch...
964 FDC-HKXR Item Models FDK Series FDFL, FDFU Series FDK, FDFL, FDFU Series (220 V/240 V) Power input (kW) Running current (A) 0.06/0.07 0.31/0.33 0.05/0.06 0.26/0.28 0.08/0.09 0.36/0.39 0.09/0.11 0.41/0.48 0.09/0.10 0.41/0.42 0.09/0.10 0.40/0.41 0.09/0.10 0.40/0.41 28 22 36 45 56 71 28 45,56 71 No...
965 FDC-HKXR • Correction factor of compressor power input 1.0 0.8 0.6 0.4 0.2 45 105 164 224 (Below, the coefficients are the same.) Total capacity of indoor unitsoperating simulataneously (Below, the coefficients are the same.) Power consumption correction coefficietnt Model FDCP2001HKXRE2 1.0 0.8...
966 FDC-HKXR System FDCP2001HKXRE2 FDCP2501HKXRE2 Refer to the selection chart. 1 to 8 units 20.2.2 Range of usage & limitations Item Indoor intake air temperature(Upper, lower limits) Outdoor air temperature(Upper, lower limits) Single direction piping lenght Indoor unit MAX 100m MAX 30m 6 min ...
967 FDC-HKXR Models FDTJ28HKXE2, 36HKXE2, 45HKXE2, 56HKXE2, 71HKXE2, 90HKXE2 20.2.3 Exterior dimensions Unit : mm Decorative Panel VIEW A VIEW D VIEW C VIEW B Space for installation and service (1) Indoor unit (a) Ceiling recessed type (FDT) Liquid piping28, 36, 45 type: φ 6.35(1/4") 56, 71, 90 ...
969 FDC-HKXR or more or more 169 295~ 325 100or more 100 or more 1500 1500 1015 40 90 885 468 417 640 97 97 446 70 50 817 178 200 240 130 8 280 750 or less (Max. Drain up) 178 460 240 200 130 100 140 20 20 74 124 56 56 (Suspension bolts pitch) (Ceiling hole size) (Suspension bolts pitch) Holes forta...
975 FDC-HKXR Model FDRJ22HKXE2 Unit : mm VIEW C Canvas Panel (Model: R-PNLC -26W-E) VIEW B VIEW A Space for installation and service Suspension bolts(M10 × 4pcs.) 130 750 345 405 433 353 295~325 150~300 299 274 199 149 35 600 or less Max. Drain up Drain (VP20) (Natural drainage) ↑ A B ↓ Canvas duct ...
985 FDC-HKXR (f) Ceiling suspension type (FDE) Model FDEJ 71HKXE2B Unit : mm Unit : mm Space for installation and service Space for installation and service Models FDEJ36HKXE2B, 45HKXE2B, 56HKXEB2 Note (1) The slope of drain piping inside the unit is able to take incline of 10 mm Note (1) The slope ...
988 FDC-HKXR Model FDKJ71HKXE2 (h) Floor standing exposed type (FDFL) Models FDFLJ28HKXE2, 45HKXE2, 71HKXE2 195 630 250 220 225 197 80 205 205 180 23 10 126 166 177 93 148 223 184 234 315 223 195 806 (1091) 197 225 32 98 Slotted hole forwall mounting4-12 × 24 Floor fixing metal brakcet (Accessory)10...
990 FDC-HKXR (2) Remote controller (Optional parts) 16 Remote controller mounting dimensions 47 7 Standard Within 0.3 mm 2 × Within 100 m 0.5 mm 2 × Within 200 m 0.75 mm 2 × Within 300 m 1.25 mm 2 × Within 400 m 2 mm 2 × Within 600 m Allowable rang of wire thickness and length ♦ Usable JIS box, JIS ...
991 FDC-HKXR (3) Individual flow divide controller (Optional Part) HPFD01R-E Notes (1) Do not operate the unit without the indoor unit connected to the individual flow divide controller. (2) Be sure to install the included strainer in the outdoor discharge gas connection pipe. (3) Do not install the...
992 FDC-HKXR (4) Outdoor unit 168 145 100 105 108 150 187 100 75 100 190 110 65 98 350 78 250 240 163 118 143 50 850 250 30 15 52 100 15 524 35 645 150 40 50 625 513 36 640 1700 24 50 1350 600 L 2 L 3 L 1 170 80 110 L 4 ( ) Back Refrigerant discharge gas piping connection pipe Wire entry hole ( φ 50...
993 FDC-HKXR 20.2.4 Exterior appearance (1) Indoor unit (a) Ceiling recessed type (FDT) ● Decorative panel (b) 2-way outlet ceiling recessed type (FDTW) ● Decorative panel (i) Standard type (ii) Attachment of ceiling material type Panel part No. Type Panel color Applicable model TW-PSA-22W-E TW-PSA-...
996 FDC-HKXR Heat exchange thermistor (Th 1 - R ) Intake Thermistor (Th 1 - A ) ø 15.88 (5/8") SVC SVH SVL SVG SVC SVH SVL Liquid piping ø 12.7 (1/2") Discharge gas piping ø 19.05 (3/4") Service valve (with charge port) Check joint Flange DPR 2 DPR 1 20SS 20SL SVS SVL DPR 3 20 VF 20 VU D...
997 FDC-HKXR 20.2.6 Selection chart Indoor unit Each indoor unit = System performance (a) Coefficient of cooling and heating capacity in relation to temperatures Outdoor unit System performance = (1) Correct the cooling and heating capacity in accordance with the conditions as follows.The net coolin...
998 FDC-HKXR (2) Correction of outdoor unit capacity according to capacity of indoor unit to be operated simultaneously (d) Correction of heating capacity in relation to the frost on the outdoor unit heat exchanger (c) When the outdoor unit is located at a lower height than the indoor unit in coolin...
999 FDC-HKXR FDCP2501HKXRE2 Capacity Correction Calculations (The procedure for both cooling and heating is the same.) Corrction whencooling? Performance correction of indoor unit = System performance [Example] FDTJ90HKXE2 23.8 = 7.65kW Indoor unit capacity Total capacity of indoor units operating s...
1000 FDC-HKXR (3) Sensible heat capacity (a) FDT Series Model FDTJ28HKXE2 12 Outdoor air temp. ( ° CDB) 27 29 31 33 35 37 39 Indoor air temperature 17.0 ° CWB TC 2.89 2.83 2.76 2.68 2.60 2.53 2.46 SHC 2.58 2.55 2.52 2.49 2.46 2.43 2.40 18.0 ° CWB TC 2.98 2.91 2.85 2.77 2.70 2.63 2.56 SHC 2.60 2.57 2...
1002 FDC-HKXR Note (1) Symbols are as follows : TC : Total cooling capacity (kW) SHC : Sensible heat capacity (kW) (b) FDTS Series Model FDTSJ22HKXE2B 11 Outdoor air temp. ( ° CDB) 27 29 31 33 35 37 39 Indoor air temperature 17.0 ° CWB TC 2.27 2.22 2.17 2.11 2.05 1.99 1.93 SHC 2.04 2.02 2.00 1.98 1....
1003 FDC-HKXR Model FDTSJ71HKXE2B 18 Outdoor air temp. ( ° CDB) 27 29 31 33 35 37 39 Indoor air temperature 17.0 ° CWB TC 7.36 7.19 7.01 6.83 6.60 6.43 6.22 SHC 5.56 5.49 5.41 5.33 5.23 5.15 5.06 18.0 ° CWB TC 7.57 7.40 7.23 7.06 6.89 6.66 6.48 SHC 5.59 5.52 5.45 5.37 5.30 5.21 5.13 19.0 ° CWB TC 7....
1004 FDC-HKXR Model FDRJ56HKXE2 14 Outdoor air temp. ( ° CDB) 27 29 31 33 35 37 39 Indoor air temperature 17.0 ° CWB TC 5.80 5.67 5.53 5.39 5.21 5.07 4.91 SHC 4.36 4.30 4.24 4.18 4.10 4.04 3.97 18.0 ° CWB TC 5.97 5.84 5.70 5.57 5.43 5.25 5.11 SHC 4.39 4.33 4.27 4.21 4.16 4.08 4.02 19.0 ° CWB TC 6.13...
1005 FDC-HKXR Model FDRJ140HKXE2 34 Outdoor air temp. ( ° CDB) 27 29 31 33 35 37 39 Indoor air temperature 17.0 ° CWB TC 14.50 14.17 13.83 13.47 13.02 12.68 12.26 SHC 10.78 10.63 10.48 10.31 10.12 9.97 9.78 18.0 ° CWB TC 14.92 14.59 14.25 13.92 13.58 13.13 12.77 SHC 10.84 10.69 10.55 10.40 10.26 10....
1006 FDC-HKXR Model FDUMJ71HKXE2 18 Outdoor air temp. ( ° CDB) 27 29 31 33 35 37 39 Indoor air temperature 17.0 ° CWB TC 7.36 7.19 7.01 6.83 6.60 6.43 6.22 SHC 5.56 5.49 5.41 5.33 5.23 5.15 5.06 18.0 ° CWB TC 7.57 7.40 7.23 7.06 6.89 6.66 6.48 SHC 5.59 5.52 5.45 5.37 5.30 5.21 5.13 19.0 ° CWB TC 7.7...
1008 FDC-HKXR Model FDEJ112HKXE2B 28 Outdoor air temp. ( ° CDB) 27 29 31 33 35 37 39 Indoor air temperature 17.0 ° CWB TC 11.60 11.33 11.07 10.77 10.42 10.15 9.81 SHC 8.72 8.60 8.48 8.35 8.20 8.08 7.93 18.0 ° CWB TC 11.94 11.67 11.40 11.13 10.86 10.51 10.21 SHC 8.77 8.66 8.54 8.42 8.31 8.16 8.04 19....
1009 FDC-HKXR Model FDKJ56HKXE2 17 Outdoor air temp. ( ° CDB) 27 29 31 33 35 37 39 Indoor air temperature 17.0 ° CWB TC 5.80 5.67 5.53 5.39 5.21 5.07 4.91 SHC 4.75 4.69 4.64 4.57 4.50 4.44 4.37 18.0 ° CWB TC 5.97 5.84 5.70 5.57 5.43 5.25 5.11 SHC 4.78 4.73 4.67 4.62 4.56 4.49 4.43 19.0 ° CWB TC 6.13...
1011 FDC-HKXR 20.2.7 Characteristics of fan (1) Cassetteria type (FDR) ● External static pressure table How to interpret the blower characteristics table Example : Case of FDRJ71HKXE2 1 2-spot blowout..................... Internal resistance increases morethan the standard 3-spot blowout.A p p r o x...
1013 FDC-HKXR Model FDRJ140HKXE2 3-spot blowerinternal resistance Square duct blower internal resistance Internal resistance without suction panel Internal resistance without filter 4-spot blower internal resistance [Standard] Standard •High Standard •Medium Standard •Low High speed • Upper limit St...
1016 FDC-HKXR 20.2.8 Noise level Notes (1) The data are based on the following conditions. Ambient air tempetature: Indoor unit 27˚C DB, 19˚C WB. Outdoor unit 35˚C DB (2) The data in the chart are measuted in an unechonic room. (3) The noise levels measured in the field are usually higher than the d...
1018 FDC-HKXR Models FDRJ71HKXE2, 90HKXE2 Noise level 44 dB (A) at HIGH41 dB (A) at MEDIUM38 dB (A) at LOW Model FDRJ112HKXE2 Noise level 46 dB (A) at HIGH43 dB (A) at MEDIUM39 dB (A) at LOW Model FDRJ140HKXE2 Noise level 47 dB (A) at HIGH44 dB (A) at MEDIUM40 dB (A) at LOW Mid octave band frequency...
1022 FDC-HKXR 20.3 ELECTRICAL DATA 20.3.1 Electrical wiring (1) Indoor unit (a) Ceiling recessed type (FDT) Models All models Meaning of marks Mark Parts name M ark Parts name M ark Parts name FM I 49F I CF I DM FS LM LS SM X1,2,3,6 X4 X5 Fan motor Internal thermostat for FM I Capacitor for FM I Dra...
1023 FDC-HKXR (b) 2-way outlet ceiling recessed type (FDTW) Models All models Meaning of marks Mark Parts name Mark Parts name Mark Parts name FM I 49F I CF I DM FS LM LS SM X1,2,3,6 X4 X5 Fan motor Internal thermostat for FM I Capacitor for FM I Drain motor Float switch (For overflow prevention) Lo...
1030 FDC-HKXR (2) Individual flow divide controller Power source 1 phase 220/240V 50Hz Power source(between indoor unit) SVH SVC SVL SVG XR, X1, XR1 XH, X2, XR2 XR3 XR4 • Meaning of marks Notes (1) This illustration shows the circuit diagram for when 1 indoor unit is connected with a central flow di...
1032 FDC-HKXR 20.4 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER (1) Remote controller (Optional parts) FDR,FDUM,FDFL and FDFU series are not provided with AUTO SWING switch. FILTER RESET CHECK F A NSPEED A U T OS W I N G TIMER SET MODE T E M PT I M E PROGRAM TIMER ON OFF P M A M SET TEMP Lo Mi Hi F...
1033 FDC-HKXR (3) Operations of major functional items under each operation mode Notes (1) : ON, : OFF, / : ON or OFF (2) Cooling and heating also include auto mode. (3) Off if jumper wire (J3) is short circulated (factory setting) and open. (4) Cooling operation (a) Cooling 1) If the sum of selecte...
1034 FDC-HKXR (5) Dehumidifying (Thermal dry) • This cooling operation is mainly for dehumidifying, with which the compressor, indoor and outdoor fans are operated in the patterns as listed in the following table and in accordance with operation blocks switched with the room temperature sensor. The ...
1036 FDC-HKXR (10) Condensate pump motor (DM) control (Only FDT, FDTW, FDTS, FDR, FDUM models) (a) Drain motor is started no sooner than the compressor is turned ON during cooling or dehumidifying operation. The drain motor continues to operate for 2 minutes after the stop of unit operation, stop wi...
1037 FDC-HKXR 1) The cumulative operating time of the compressor comes up to 45 minutes after completion of a defrosting operation, or it comes up to 30 minutes after a heating operation starts (the remote controller is turned on). 2) Five minutes has passed after the compressor was turned off and o...
1039 FDC-HKXR The high pressure control consists of the HP protection, HP-A control, HP-B control and LP control and the order of priority among them is assigned as HP protection >HP-A > LP > HP-B down > HP-B up. (16) High pressure control Pressure switch [If 63H1: 3.24 open/2.65 close M...
1041 FDC-HKXR (a) In the case that at least one in-door unit requires the maximum frequency supply during cooling or heating operation for 6 minutes continuously, the compressor operating frequency is increased by 10 Hz. After that, the maximum frequency is increased by 10 Hz every continuous 6 minu...
1042 FDC-HKXR (19) Devices related to unit protection and maintenance (a) Test Run Mode The test run mode can be set from the outside by using the switch SW3-4,5 on the outdoor unit control circuit board (i) Switch function Remarks : Fuzzy control is not performed in test run operation. (Operation i...
1044 FDC-HKXR (k) Protection of Power Transistor from Overheat When the temperature of the power transistor increases to the set temperature, stop the inverter immediately and let is reset by itself 3 minutes later. If the power transistor is overheated again within 2 hours, turn off 52C, bring it t...
1045 FDC-HKXR 20.5 APPLICATION DATA SAFETY PRECAUTIONS • Please read these “Safety Precautios” first then accurately execute the installation work. • Though the precautionary points indicated herein are divided under two headings, WARNING and CAUTION , those points which are related to the strong po...
1049 FDC-HKXR 3) Face-to-face installation Dimension Unit: mm Distance Item Diagonal Up air outlet L 1 1500 or more 500 or more L 2 1000 or more 500 or more Note (1) Make the air outlet the diagonal air outlet (standard) or the up air outlet (option). 4) Side-to-side & face-to-face installation ...
1050 FDC-HKXR (3) Installation Fix the unit in a proper way according to the condition of a place where it is installed by referring to the following. (a) Fix the unit to the foundation with anchor bolts. (b) When installing the unit, be sure to fix the pedestal of the unit with bolts. (c) Install t...
1051 FDC-HKXR 20.5.4 Refrigerant piping (1) Precautions no refrigerant piping work for prevention against compressor lock Compressor trouble including lock and motor burn-out is due to faulty parts but mainly concerned in installation and refrigerant piping conditions, The precautions for refrigeran...
1052 FDC-HKXR (2) Refrigerant piping size selection Liquid piping Outdoor unit connection pipe Downstream indoor unit capacity total (1) FDCP2001 type Branch line Indoor unit connection pipe models Indoor side Outdoor side Flow divide controller connection pipe FDCP2501 type 160 or more less than 16...
1053 FDC-HKXR Liquid piping Flow dividerpipe set for ver-tical divides (DIS-V1KXR3E) Discharge gas piping Intake gas piping Individual flowdivide controller Individual flowdivide controller Indoor unit Outdoor unit Indoor unit (Example) Shapes of individual flow divide controller accessories (HPFD1R...
1054 FDC-HKXR Use reducer A and process the φ 12.7 portion into a flare. Cut off reducer B using a pipe cutter as shown in the illustration and make a flare. Process the included reducer as illustrated below.Use the flare nuts included with the individual flow divide controller. When the indoor unit...
1056 FDC-HKXR 2) Connection to lower direction. a) Cut off the accessory intake gas side connection pipe and then connect to the intake gas side atraight pipe. b) Remove the back hall blank, pass through the hole the intake gas side, discharge gas side, and liquid pipes, and then connect them to the...
1057 FDC-HKXR (4) Heat insulation ;;; ;;; ;;; ;;; ;;; ;; ;; Exterior tape Use insulation material with good resistance heat properties (120 ˚C or more). Gas lines Liquid piping Wires for connecting indoorand outdoor units Insulation (i) There is a need to insulate both gas and liquid piping with hea...
1059 FDC-HKXR (3) Wiring system Diagram When No. 4 shielding wire is used, always ground the single wire side of the shielding wire . In addition, using the shielding wire is helpful to prevent the incorrect connection between 5V DC and 220/240V or 380/415V AC because the discrimination from the pow...
1060 FDC-HKXR Do not connect high voltage wire 380/415V to signal wires, as these wires are DC 5V. Signal wires should be connected so that the terminal Nos. conform with each other for between outdoor and between indoor units. However, they will work properly if different polarities are connected. ...
1062 FDC-HKXR (c) Settings for main and secondary units when multiple remote controllers are used. Up to two remote controllers can be used for each indoorunit (or each group of indoor units).1) There are two methods for arranging this. Onemethod is to take a remote control connection wire(3-strand)...
1064 FDC-HKXR 1) Set the address switch of outdoor unit at 49. (This is set at 49 at shipment from factory.) 2) Set the address switch of indoor unit at 49. (This is set at 49 at shipment from factory) 3) Turn power on for the indoor and outdoor units. Addresses are set automatically. (No. in a rang...
1065 FDC-HKXR Detail of setting from the remote controller 1) If the power switch is turned on, the outdoor No. on the display flashes, and "--" on the return air temperature displaysection and "U--" on the time display section are lit.If power is not supplied to the outdoor unit, th...
1068 FDC-HKXR 20.6. MAINTENANCE DATA 20.6.1 Diagnosis of Microcomputer circuit (1) Confirmation of the error code on the remote controller (by pressing the inspection switch) and the inspection display and normal display lamps on PCBs of indoor/ outdoor units The microcomputer detects errors on elec...
1069 FDC-HKXR E11 Keeps flashing Stays OFF Keeps flashing Stays OFF Remote controller addresses have been set while more than one units of remote controller are connected. 2) Check Indicator Table Whether a failure exists or not on the indoor unit and outdoor unit can be known by the contents of rem...
1072 FDC-HKXR Error Power supply check (indoor/outdoor unit) Replacement or repair of defective parts Test run/adjustment Check of unit controller Check of inspection display [In-door/outdoor unit PCB, remote c o n t r o l l e r o r I n d i c a t i o n b o a r d ] Check of inspection display [In-d o...
1073 FDC-HKXR Error Are the return air temperature and Center/ Remote displayed on the remote controller? Power switch OFFPower supply line error Check the errorcode displayed ON/OFFswitch OFF Microcomputerout of control Power supply line error See page 1077 Cause is accidental (noise, etc.)and the ...
1074 FDC-HKXR Interisified shielding of control section Use the shield or twist pair wires Remote controller wire Remote controller Put in a steel case Separate from cutting machine as for as possible. This is very effective because the effect of noise is in inverse proportion to 1.5 times of distan...
1077 FDC-HKXR Did turn off the power of outdoor unit during operation? Power supplyON NO (1) YES YES NO Note (1) This case is limited to the separate power supplies to indoor/outdoor units. (Combination of (indoor unit) red LED 2 time flash and (outdoor unit) green LED stays off means that the power...
1078 FDC-HKXR Indoor unit Red LED Green LED Stays OFF Keeps flashing Red LED Green LED 8 time flash Keeps flashing Outdoor unit Is the unit No. duplicated on outdoor units? Correction YES NO Defective outdoor unit PCB Replacement (Defective unit No. read circuit) Note (1) When the PCB is defective, ...
1079 FDC-HKXR Is the outdoor unit heat exchanger hermistor connector OK? Repair YES NO Are the outdoor unit heat exchnger thermistor characteristics OK, is there any broken wire? Defective outdoor unitheat exchanger thermistor → Replacement YES NO Is the outdoor air temperature thermistor connector ...
1080 FDC-HKXR 9 Red LED Green LED Stays OFF Keeps flashing Outdoor unit Red LED Green LED 3 time flash Keeps flashing Indoor unit Note (1) When the wire of 63H 1 is broken from the moment of power on, the error E 40 is displayed 40 minutes later. If the operation is started in this period of time, t...
1082 FDC-HKXR Is the current cut function activated? Is the insullaiton resistance of the compressor (1) proper? NO YES YES NO YES NO YES NO Notes (1) When a short-circuit or ground-fault occurs in the compressor motor, the current cut function is also activated. Notes (1) If the insulation resistan...
1083 FDC-HKXR Does the LD1 (Green) on the inverter PCB flash? Is the power supply line normal? Does the LD4 (red) on the inverter PCB light? (2) Defective inverter PCB Repair • Defective inverter PCB• Defective outdoor unit PCB• Broken Cnl in No.5 (See next page)- The outdoor unit PCB cannot receive...
1084 FDC-HKXR Power supply detected between outdoor unit terminal 5 ~PCB faston terminal 6 (black)? Defective 20 S → Replacement Defective outdoor unit PCB → Replacement Four way valve does not switch during heating operation • When communication is checked by the connector CnI, each value will be a...
1086 FDC-HKXR Defective indoor unit PCB → Replace. NO YES YES (1) Defective SVH (high pressure gas side solenoid valve) → Replace. NO YES Defective relay (XH) → Replace. Defective relay → Replace. Is heat outputted? NO Are solenoid valve control relays OK? Is AC 200V applied at shunt controller conn...
1090 FDC-HKXR YES YES YES NO NO YES YES YES NO YES YES YES YES YES YES YES YES Check the outdoor unit control PCB. Check the wire between thecapacitor and Cn2 and checkthe connector. Check the compressor. Defective inverter PCB → Replacement Defective inverter PCB → Replacement. Defective capacitor ...
19.2.6 Selection chart (1) Correct the cooling and heating capacity in accordance with the conditions as follows. (3)Sensible heat capacity FDFUJ 28HKXE2 45HKXE256HKXE271HKXE2 (1) Correct the cooling and heating capacity in accordance with the conditions as follows. (3)Sensible heat capacity FDCJ/ F...
19.5 APPLICATION DATA SAFETY PRECAUTIONS 19.5.1 Installation of indoor unit SAFETY PRECAUTIONS 19.5.1 Installation of indoor unit (1) Ceiling recessed type (FDT) (2) 2-Way outlet ceiling recessed type (FDTW) (3) 1-Way outlet ceiling recessed type (FDTS) (4) Cassetteria type (FDR) (5) Satellite ducte...
19.6 MAINTENANCE DATA (1)Before starting troubleshooting (P904 ~ P908) (2)Procedures of trouble diagnosis (P908 ~ P933) (3)Trouble diagnosis at the inverter side (P933 ~ P934)
20.2.6 Selection chart (1) Correct the cooling and heating capacity in accordance with the conditions as follows. (3)Sensible heat capacity FDFUJ 28HKXE2 45HKXE256HKXE271HKXE2 (1) Correct the cooling and heating capacity in accordance with the conditions as follows. (3)Sensible heat capacity FDTJ 28...
20.5 APPLICATION DATA SAFETY PRECAUTIONS 20.5.1 Installation of indoor unit SAFETY PRECAUTIONS 20.5.1 Installation of indoor unit (1) Ceiling recessed type (FDT) (2) 2-Way outlet ceiling recessed type (FDTW) (3) 1-Way outlet ceiling recessed type (FDTS) (4) Cassetteria type (FDR) (5) Satellite ducte...
20.6.1 Diagnosis of Microcomputer circuit (1) Confirmation of the error code on the remote controller (by pressing the inspection switch) and the inspection display and normal display lamps on PCBs of indoor/ outdoor units (P1068 ~ P1072) (2) Procedures of trouble diagnosis (P1072 ~ P1087) (3) When ...
Mitsubishi Manuals
-
Mitsubishi PKA-A18GA
User Manual
-
Mitsubishi PKA-A18GA
Installation Manual
-
Mitsubishi PKA-A18GAL
User Manual
-
Mitsubishi PKA-A18GAL
Installation Manual
-
Mitsubishi PCA-A42GA1
User Manual
-
Mitsubishi PCA-A42GA1
Installation Manual
-
Mitsubishi MSZ-FH18NA
User Manual
-
Mitsubishi MSZ-FH18NA
Installation Manual
-
Mitsubishi MSZ-D36NA
User Manual
-
Mitsubishi MSZ-D36NA
Installation Manual
-
Mitsubishi WD-82742
User Manual
-
Mitsubishi MSZ-FE09NA
User Manual
-
Mitsubishi MSZ-FE09NA
Installation Manual
-
Mitsubishi LT-46164
User Manual
-
Mitsubishi MSY-D36NA-8
User Manual
-
Mitsubishi MSY-D36NA-8
Installation Manual
-
Mitsubishi MSY-A15NA-1
User Manual
-
Mitsubishi MSY-A15NA-1
Installation Manual
-
Mitsubishi WD-73638
User Manual
-
Mitsubishi PKA-A36FA
User Manual