4 AIBUS UDIAN Automation AI-501, AI-518, AI-519, AI-701, AI-702M, AI-704M, AI-706M, AI-719 http://www.yudian.us HMI Setting: Parameters Recommend Option Notes PLC type AIBUS Com port RS485 2W RS232 Baud rate 9600 9600, 19200 Parity bit None Data Bits 8 Stop Bits 2 HMI Station No. 0 PLC Station No. 1...
23 Allen Bradley PLC5 http://www.ab.com HMI Setting: Parameters Recommend Option Notes PLC type AB PLC5 Com port RS232 Baud rate 19200 9600, 19200 Parity bit None Even, Odd, None Data Bits 8 8 Stop Bits 1 1 HMI Station No. 0 PLC Station No. 1 1-31 PLC Setting: Communication mode DF1 Full Duplex prot...
27 Baumuller Servo http://www.baumuller.com/ HMI Setting: Parameters Recommend Option Notes PLC type Baumuller Com port RS485 4W COM1 Baud rate 19200 9600, 19200 Parity bit Even Even, Odd, None Data Bits 8 7 or 8 Stop Bits 1 1 or 2 HMI Station No. 0 PLC Station No. 0 Defaults Baumuller Servo Setting...
Copley Controls Digital Servo Driver & Controllers, Xenus, Xenus Micro, Accelnet, Accelnet Micro, Stepnet series http://www.copleycontrols.com/motion/ HMI Setting: 33 Parameters Recommend Option Notes PLC type Copley Controls Com port RS232 Baud rate 9600 9600~115200 Parity bit None Even, Odd, N...
35 Danfoss ECL Apex20 Controller http://www.danfoss.com/ HMI Setting: Parameters Recommend Option Notes PLC type Danfoss ECL Apex20 Com port RS232 Baud rate 9600 Parity bit None Data Bits 8 Stop Bits 1 PLC Station No. 1 Device address: Device Type Format Range Memo Flag DDDD 0-8191 Input DDD 0-511 O...
37 DELTA DVP DELTA DVP series http://www.deltadriver.com HMI Setting: Parameters Recommend Option Notes PLC type DELTA DVP Com port RS232 RS232, RS485 Baud rate 9600 9600, 19200 Parity bit Even Even, Odd, None Data Bits 7 7, 8 Stop Bits 1 1 HMI Station No. 0 PLC Station No. 1 0-255 PLC Setting: Comm...
39 EMERSON PLC EC20 Support Emerson PLC EC20 Series. (Modbus RTU Protocol) HMI Setting: Parameters Recommend Option Notes PLC type EMERSON PLC EC20 Com port RS232 RS232, RS422, RS485 Baud rate 9600 9600, 19200,115200 Parity bit Even Even, Odd, None Data Bits 8 7 or 8 Stop Bits 1 1 or 2 HMI Station N...
41 FATEK FB series FATEK FBs series, FB MC series, FB MA series need FB-DTBR converter. http://www.fatek.com/ HMI Setting: Parameters Recommend Option Notes PLC type FATEK FB Series Com port RS232 RS232/RS485/Ethernet Must match the PLC’s port setting. Baud rate 9600 Must match the PLC’s port settin...
44 Fuji NB Series PLC http://www.fujielectric.co.jp/fcs/eng/ HMI Setting: Parameters Recommend Option Notes PLC type Fuji NB Series Com port RS485 4W Baud rate 19200 Parity bit Odd Data Bits 8 Stop Bits 1 PLC Station No. 0 PLC Setting: Communication mode NITP protocol / PLC Password (default is 0) D...
52 HAN YOUNG Temperature Controller http://hynux.com/kor/ HMI Setting: Parameters Recommend Option Notes PLC type Heng Young Seires Com port RS485 4W Must match the PLC’s port setting. Baud rate 9600 Must match the PLC’s port setting. Parity bit None Even, Odd, None Must match the PLC’s port setting...
Heng Yuan Sensor EU sereis, EU5 series, EU10 series. http://www.hysensor.com.cn HMI Setting: 53 Parameters Recommend Option Notes PLC type Heng Yuan Sensor RS485 2W Com port Baud rate 9600 Parity bit Even Data Bits 8 Stop Bits 1 0 HMI Station No. PLC Station No. 2 1-31 Online Simulator YES Extend ad...
55 HITACHI EHV HITACHI Web site: http://www.hitachi-ies.co.jp/english/products/plc/index.htm HMI Setting: Parameters recommend Option Notes PLC type HITACHI EHV Com port Ethernet Port no. 3004 3004~3007 Device address: Bit/Word Device type Format Range Memo B X hhhh(h) 0~FFFF(F) External Input-bit(X...
61 HUST H4X HUST CNC Controller H4 Series http://www.hust.com.tw/ HMI Setting: Parameters Recommend Option Notes PLC type HUST H4X Com port RS-232 CPU port PLC Station No. Null Baud rate 38400 9600,19200,38400,57600 Data bit 7 Parity bit Even Stop bit 2 Turn delay 5 Device address: Bit/Word Device T...
63 IDEC IDEC Micro3, Micro3C, MicroSmart, OpenNet Controller series http://www.idec.com HMI Setting: Parameters Recommend Option Notes PLC type IDEC Micro Support Extend address mode Com port RS232 RS232, RS485 Baud rate 9600 9600, 19200 Parity bit Even Even, Odd, None Data Bits 7 7, 8 Stop Bits 1 1...
66 Intelligent Servo Intelligent Servo supports IDM640, IDM240. http://www.techsoftmotion.com HMI Setting: Parameters Recommend Option Notes PLC type Intelligent Servo Com port RS232 Baud rate 9600 9600~115200 Parity bit None Even, Odd, None Data Bits 8 7 or 8 Stop Bits 1 1 or 2 HMI Station No. 0 PL...
67 JUSTFI Controller Justfi weighing instruments, Industrial Batching Controller supports XK31CB4, XK31CB6. http://www.justfi.com HMI Setting: Parameters Recommend Option Notes PLC type Justfi controller Com port RS232 Baud rate 9600 9600, 19200 Parity bit Even Even, Odd, None Data Bits 7 7 or 8 Sto...
69 KERNEL SISTEMI Kernel systemi DMX 30 http://www.kernel.modena.it/ HMI Setting: Parameters Recommend Option Notes PLC type Kernel sistemi Com port RS232 RS485 Baud rate 19200 9600 Parity bit N Data Bits 8 Stop Bits 1 PLC Station No. 1 Must match the PLC’s port setting Device address: Bit/Word Devi...
70 KEYENCE KV series KEYENCE KV series, KV10~80 http://www.keyence.com/ HMI Setting: Parameters Recommend Option Notes PLC type KEYENCE KV-16 Com port RS232 RS232 Must match the PLC’s port setting. Baud rate 9600 Must match the PLC’s port setting. Parity bit Even Must match the PLC’s port setting. D...
78 KOYO CLICK PLC Series KOYO CLICK PLC series http://www.automationdirect.com HMI Setting: Parameters Recommend Option Notes PLC type CLICK Com port RS232 Baud rate 38400 Communications Port1 (fixed) Reference PLC Specification Parity bit Odd Communications Port1 (fixed) Reference PLC Specification...
80 KOYO DirectLogic KOYO DirectLogic series PLC DL05, DL06 , DL105, DL205, DL305 and DL405 series http://www.automationdirect.com HMI Setting: Parameters Recommend Option Notes PLC type KOYO DIRECT Com port RS232 RS232, RS485 Baud rate 9600 9600, 19200, 38400 Parity bit Odd Even, Odd, None Data Bits...
84 KOYO DirectLogic Ethernet Module KOYO DirectLogic series, model H0-ECOM100 http://www.automationdirect.com HMI Setting: Parameters Recommend Option Notes PLC type KOYO ETHERNET Com port Ethernet, UDP/IP PLC Station No. No need to set station no. 0 TCP/IP port 28784 Device address: Bit/Word Device...
86 Lenze PLC Model No. : 9300/8200 series Pass-through 2102IB fieldbus module:RS485(LECOM B) http://www.lenze.de HMI Setting: Parameters Recommend Option Notes PLC type Lenze Com port RS485 RS485 Baud rate 9600 9600, 19200 Parity bit Even Even, Odd, None Data Bits 7 7,8 Stop Bits 1 1, 2 HMI Station ...
88 LS GLOFA Cnet LS GLOFA GM6/GM7 CPU port. G7L-CUEB / G6L-CUEB / G4L-CUEA / G3L-CUEA Cnet module. http://www.lgis.com/ HMI Setting: Parameters Recommend Option Notes PLC type LS GLOFA Cnet Com port RS232 RS232/RS485 2W/4W Baud rate 9600 9600~115200 Parity bit None Even, Odd, None Data Bits 8 7, 8 S...
102 LIYAN EX series LIYAN PLC Ex/Ex1s/Ex1n/Ex2n series http://www.liyanplc.com/ HMI Setting: Parameters Recommend Option Notes PLC type Mitsubishi FX0n/FX2 Com port RS232 RS232 Must match the PLC’s port setting. Baud rate 9600 9600~115200 Must match the PLC’s port setting. Parity bit Even Even, Odd,...
107 Memobus (YASKAWA MP Series controllers) YASKAWA MP2200, MP2300, MP2300S, MP9xx communication module http://www.yaskawa.com/ HMI Setting: Parameters Recommend Option Notes PLC type Memobus Com port RS485/Ethernet RS232/RS485 2w/4w, Ethernet Must match the PLC’s port setting. Baud rate 19200 9600~...
Ethernet: Direct connect (crossover cable) MT8000 Wire color Ethernet Module RJ45 Ethernet RJ45 1 TX+ White/Orange 3 RX+ 2 TX- Orange 6 RX- 3 RX+ White/Green 1 TX+ 4 BD4+ Blue 4 BD4+ 5 BD4- White/Blue 5 BD4- 6 RX- Green 2 TX- 7 BD3+ White/Brown 7 BD3+ 8 BD3- Brown 8 BD3- PLC Ethernet Setting: 1. Use...
111 Memory Map protocol Memory Map protocol is similar to IBM 3764R communication protocol. The MT8000 reserves 512 words of Data memory for use with this protocol. The MT8000 must update the values in these words. The MT8000 uses the words to display data and control parts status on its screen. Whe...
113 MITSUBISHI A1S MITSUBISHI A1S http://www.mitsubishi-automation.com/ HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI A1S Com port RS232 Baud rate 9600 Parity bit Odd Data Bits 8 Stop Bits 1 HMI Station No. 0 PLC Station No. 0 PLC Setting: Communication mode 9600, Odd, 8, 1 Devi...
116 MITSUBISHI A2A MITSUBISHI A2A http://www.mitsubishi-automation.com/ HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI A2A Com port RS232 Baud rate 9600 Parity bit Odd Data Bits 8 Stop Bits 1 HMI Station No. 0 PLC Station No. 0 PLC Setting: Communication mode 9600, Odd, 8, 1 Devi...
119 MITSUBISHI A2US MITSUBISHI A2US http://www.mitsubishi-automation.com/ HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI A2US Com port RS232 Baud rate 9600 Parity bit Odd Data Bits 8 Stop Bits 1 HMI Station No. 0 PLC Station No. 0 PLC Setting: Communication mode 9600, Odd, 8, 1 D...
131 MITSUBISHI FX2n Mitsubishi FX1n/FX2n series PLC http://www.mitsubishi-automation.com HMI Setting: Parameters Recommend Option Notes PLC type Mitsubishi FX2n Mitsubishi FX2n Com port RS485 RS232/RS485 Baud rate 9600 9600/19200/38400/5760 0/115200 Parity bit Even Data Bits 7 Stop Bits 1 HMI Statio...
136 MITSUBISHI FX3U Mitsubishi FX3U/FX3UC http://www.mitsubishi-automation.com HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI FX3u Com port RS485 4w RS232/RS485 2w/4w Baud rate 9600 9600/19200 must same as the PLC setting Parity bit Even must same as the PLC setting Data Bits 7 m...
138 MITSUBISHI FX3U-ETHERNET MITSUBISHI FX SERIES, Module: FX3U-ENET http://www.mitsubishi-automation.com HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI FX3u (Ethernet) Com port Ethernet PLC Station No. 0 (default) Refer Module Setting TCP/IP port 5001(default) Refer Module Setti...
145 MITSUBISHI Q00J CPU MITSUBISHI Q00J CPU HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI Q00J Com port RS-232 CPU port PLC Station No. Baud rate 115200 9600,19200,38400,57600,115200 Data bit 8 Parity bit Odd Stop bit 1 Device address: Bit/Word Device Type Format Range Memo B SM...
147 MITSUBISHI Q02H Mitsubishi Q02H CPU port. http://www.mitsubishi-automation.com HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI Q02H Com port RS232 RS485 4W, RS232 Baud rate 115200 115200 only Parity bit Odd Data Bits 8 Stop Bits 1 HMI Station No. 0 PLC Station No. 0 Online Sim...
153 MITSUBISHI Q06H Mitsubishi Q06H CPU port. http://www.mitsubishi-automation.com HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI Q06H Com port RS232 RS485 4W, RS232 Baud rate 115200 115200 only Parity bit Odd Data Bits 8 Stop Bits 1 HMI Station No. 0 PLC Station No. 0 Online Sim...
MITSUBISHI QJ71 Mitsubishi Q series PLC with QJ71C24 communication module, Q00, Q01, Q00UJ CPU port. http://www.mitsubishi-automation.com HMI Setting: Parameters Recommend Option Notes PLC type MITSUBISHI Melsec_QJ71 Com port RS232 RS485 4W, RS232 Baud rate 9600 9600~115200 Parity bit Odd Data Bits ...
166 MODBUS ASCII MODBUS ASCII CONTROLLER http://www.modbus.org HMI Setting: Parameters Recommend Option Notes PLC type Modbus ASCII Com port RS485 RS232/RS485 Baud rate 9600 9600/19200/38400/57600/ 115200 Parity bit Even Even, Odd, None Data Bits 8 7,8 Stop Bits 1 1,2 HMI Station No. 0 Does not appl...
169 MODBUS RTU MODBUS RTU CONTROLLER http://www.modbus.org HMI Setting: Parameters Recommend Option Notes PLC type Modbus RTU Com port RS485 RS232/RS485 Baud rate 9600 9600~115200 Parity bit Even Even, Odd, None Data Bits 8 7,8 Stop Bits 1 1,2 HMI Station No. 0 Does not apply to this protocol PLC St...
181 Ethernet: Direct connect (crossover cable) MT8000 Ethernet RJ45 Wire color Modbus TCP Device RJ45 1 TX+ White/Orange 3 RX+ 2 TX- Orange 6 RX- 3 RX+ White/Green 1 TX+ 4 BD4+ Blue 4 BD4+ 5 BD4- White/Blue 5 BD4- 6 RX- Green 2 TX- 7 BD3+ White/Brown 7 BD3+ 8 BD3- Brown 8 BD3- Driver Version: Versio...
188 OMRON CJ1/CS1 Ethernet OMRON CJ1M, CJ1H, CJ1G, CS1H and CS1G. (Ethernet FINS), http://oeiweb.omron.com/oei/Products-PLC.htm HMI Setting: Parameters Recommend Option Notes PLC type OMRON CJ1/CS1 (Ethernet) Com port Ethernet TCP port 9600 HMI Station No. 0 PLC Station No. 0 PLC Setting: Communicat...
191 OMRON E5CN OMRON E5CN series Temperature controller with communication option. E5EN/CN/GN series http://oeiweb.omron.com HMI Setting: Parameters Recommend Option Notes PLC type OMRON E5CN Com port RS485 2W Baud rate 9600 9600/19200/38400/57600 /115200 Parity bit Even Even, Odd, None Data Bits 7 ...
193 Panasonic FP NAIS(Matsushita) FP series include FP-X, FP- Σ , FP0, FP1, FP2, FP2SH, FP10SH and FP3 Ethernet support FP-X with AFPX-COM5. http://pewa.panasonic.com/ HMI Setting: Parameters Recommend Option Notes PLC type Matsushita FP Com port RS232 RS232/RS485 Ethernet Must match the PLC’s port ...
197 Panasonic MINAS A4 Series Panasonic MINAS A4 series Servo Drive HMI Setting: Parameters Recommend Option Notes PLC type PANASONIC MINAS A4 Com port RS232 Axis no. 0 (master station only) 0 ~ F (slave) Baud rate 9600 Parity bit None Data Bits 8 Stop bit 1 Device address: Bit/Word Device Type Form...
201 Parker Compax3 Parker Compax3 Servo Drive http://www.parker.com HMI Setting: RS232 Parameters Recommend Option Notes PLC type Parker Compax3 [V1.50] Com port RS-232 Must match the PLC’s port setting. Baud rate 115200 Must match the PLC’s port setting. Parity bit None Even, Odd, None Must match t...
204 Parker SLVD Servo Parker SLVD Servo, SLVD1N, SLVD2N, SLVD5N, SLVD7N, SLVD10N, SLVD15N, SLVD17N. http://www.parker.com/portal/site/PARKER/ HMI Setting: Parameters Recommend Option Notes PLC type Parker SLVD Series Com port RS485 4w Baud rate 9600 9600/19200 must same as the PLC setting Parity bit...
206 SAIA PCD PGU mode SAIA PCD series PGU mode. http://www.saia-burgess.com/ HMI Setting: Parameters Recommend Option Notes PLC type SAIA PCD PGU mode SAIA PCD S-BUS mode PDS driver Com port RS232 RS232, RS485 Baud rate 9600 9600, 19200 Parity bit Even Even, Odd, None Data Bits 7 7,8 Stop Bits 1 1 H...
210 Schleicher XCX20C Schleicher XCx-Systems Ethernet port. Schleicher XCS series, 20C model http://www.schleicher-electronic.com HMI Setting: Parameters Recommend Option Notes PLC type Schleicher XCS20 Com port RS232 Baud rate 38400 Parity bit N Data Bits 8 Stop Bits 1 HMI Station No. 0 PLC Station...
SEW Eurodrive MOVITRAC SEW Eurodrive series, model MOVITRAC-07 inverter, MovitracB http://sg.sew-eurodrive.com/ HMI Setting: Parameters Recommend Option Notes PLC type SEW Eurodrive MOVITRAC Com port RS-485 0 0~255 PLC Station No. Baud rate 9600 Data bit 8 Parity bit Even Stop bit 1 Device address: ...
231 Telemecanique UniTelWay Modicon TSX Micro&Nano&Neza series PLC http://www.modicon.com HMI Setting: Parameters Recommend Option Notes PLC type Telemecanique UniTelWay Com port RS485 RS232/RS485 Baud rate 9600 9600~115200 Must same as the PLC setting Parity bit Odd Even, Odd, None Must sam...
233 TOSHIBA T series Toshiba T series, S2E http://www.tic.toshiba.com HMI Setting: Parameters Recommend Option Notes PLC type Toshiba T Serial Com port RS232 RS232/RS485 In accordance with plc port Baud rate 9600 9600, 19200,38400,57600,115200 Must same as the PLC setting Parity bit Odd Even, Odd, N...
235 TOSHIBA TC mini series TOSHIBA MACHINE CO., JAPAN Web Site: http://www.toshiba-machine.co.jp HMI Setting: Parameters Recommend Option Notes PLC type Provisor TC200 Provisor TC200 Com port RS232 RS232 In accordance with plc port Baud rate 9600 9600, 19200 Must same as the PLC setting Parity bit N...
240 VIGOR VIGOR M Series http://www.vigorplc.com.tw/ HMI Setting: Parameters Recommend Option Notes PLC type VIGOR Com port RS232 RS232, RS485 4wires, Baud rate 19200 Parity bit Even Data Bits 7 Stop Bits 1 HMI Station No. 0 PLC Station No. 1 PLC Setting: Communication mode None Device address: Bit/...
YAMAHA ERCD HMI Setting: 245 Device address: Bit/Word Device type Format Range Memo Word P ddd 0-999 Read/Write, PNT point data Word SWI ddd 0 Write only , RW0=program number , Switches program number to be run Word ORG ddd 0 Write only , Returns to origin Word Reset ddd 0 Write only , Reset program...
248 Wiring diagram: RS-232: CPU port MT8000 RS232 CPU port cable 9P D-SUB KM11 RS-232 MT8000 RS232 9P D-SUB COM1 COM2 COM3 3 TX 4 TX 7 TX 3 RXD 2 RX 6 RX 8 RX 2 TXD 5 GND 5 GND 5 GND 5 GND RS-232: LC11 MT8000 RS232 LC11 Computer 9P D-SUB Female Link module RS232 Port COM1 COM2 COM3 3 TX 4 TX 7 TX 2 ...
P.S Because use Personal computer link, when you connecting to PLC it will delay about 20sec for test communication. How to Setting YOKOGAWA PLC Communcation configuration. YOKOGAWA FA-M3 CPU SP55-5N (same SP35-5N) [File]->[New Project] to create a new project 249
MT6050i Com Port Connection Guide Bottom View MT6050i Pin assignment of the 9 Pin, Male, Pin assignment of the 9 Pin, Male, SUB-D, COM1 [RS-232]/ [RS-485], COM3 [RS-485] Port. Only Com1[RS485 2W] support MPI 187.5K. Com1[RS485] Pin# Symbol Com1[RS232] Com3[RS485] 4 wire 2 wire 1 Rx- Rx- Data- 2 Rx+ ...
Mitsubishi Manuals
-
Mitsubishi PKA-A18GA
User Manual
-
Mitsubishi PKA-A18GA
Installation Manual
-
Mitsubishi PKA-A18GAL
User Manual
-
Mitsubishi PKA-A18GAL
Installation Manual
-
Mitsubishi PCA-A42GA1
User Manual
-
Mitsubishi PCA-A42GA1
Installation Manual
-
Mitsubishi MSZ-FH18NA
User Manual
-
Mitsubishi MSZ-FH18NA
Installation Manual
-
Mitsubishi MSZ-D36NA
User Manual
-
Mitsubishi MSZ-D36NA
Installation Manual
-
Mitsubishi WD-82742
User Manual
-
Mitsubishi MSZ-FE09NA
User Manual
-
Mitsubishi MSZ-FE09NA
Installation Manual
-
Mitsubishi LT-46164
User Manual
-
Mitsubishi MSY-D36NA-8
User Manual
-
Mitsubishi MSY-D36NA-8
Installation Manual
-
Mitsubishi MSY-A15NA-1
User Manual
-
Mitsubishi MSY-A15NA-1
Installation Manual
-
Mitsubishi WD-73638
User Manual
-
Mitsubishi PKA-A36FA
User Manual