Trademarks MELDAS, MELSEC, EZSocket, EZMotion, iQ Platform, MELSOFT, GOT, CC-Link, CC-Link/LT and CC-LinkIE are either trademarks or registered trademarks of Mitsubishi Electric Corporation in Japan and/or othercountries. Ethernet is a registered trademark of Xerox Corporation in the United States a...
I Alarms Operation Errors (M) I - 1 (Note) This alarm description is common for M700V/M70V/E70 Series. It is written on the assumption that all option functions are added.Confirm with the specifications issued by the machine tool builder before starting use. 1. Operation Errors (M) M01 Dog overrun 0...
I Alarms Operation Errors (M) I - 3 M01 Chopping axis R-pnt incomplete 0050 Details Chopping mode has been entered while the chopping axis has not completed reference posi-tion return. All axes interlock has been applied. Remedy - Reset the NC or disable the "chopping" signal, and then carry...
I Alarms Operation Errors (M) I - 4 M01 Illegal op in wk instl err cmp 0070 Details One of the following operations was attempted during workpiece installation error compensa-tion. - Manual interruption- Automatic operation handle interruption- MDI interruption- PLC interruption Remedy - Return the ...
I Alarms Operation Errors (M) I - 6 M01 Program restart machine lock 0126 Details Machine lock was applied on the return axis being manually returned to the restart position. Remedy - Cancel the machine lock and resume the operation. M01 Rot axis parameter error 0127 Details Orthogonal coordinate ax...
I Alarms Operation Errors (M) I - 7 M01 No speed set out of soft limit 0160 Details The axis, without any maximum speed outside of the soft limit range set, was returned fromthe outside of the soft limit range. Remedy - Correct the "#2021 out_f (Maximum speed outside soft limit range)" setti...
I Alarms Operation Errors (M) I - 8 M01 Tool length compensation amt 0 0252 Details The tool length compensation amount for performing the R-Navi indexing type 2 is 0. Remedy - Set the tool length compensation amount for performing the indexing type 2 to a value other than 0. M01 Feat coord ill w/ m...
I Alarms Operation Errors (M) I - 10 M01 Synchronization mismatch 1030 Details Different M codes were each commanded as synchronization M code in each of the two partsystems. Synchronization with the "!" code was commanded in another part system during M code syn-chronization. Synchronizatio...
I Alarms Operation Errors (M) I - 11 M01 Cont ax superimpos II prm illg 1044 内容 - There is a mistake in the setting of the superimposition control base axis parameter (#2089 bsax_pl). - Superimposition control is not available under the current parameter settings. 処置 - Correct the parameter. M01 Sp ...
I Alarms Operation Errors (M) I - 12 M91 INVALID MEASUR. 0089 Details Sensor signal illegal ON Sensor has already been ON when TLM mode is turned ON. The travel amount was so smallthat the tool contacted the sensor. Remedy All axes are interlocked when this alarm has occurred. Turn the TLM mode OFF ...
I Alarms Stop Codes (T) I - 13 2. Stop Codes (T) T01 Axis in motion 0101 Details Automatic start is not possible as one of the axes is moving. Remedy - Try automatic start again after all axes have stopped. T01 NC not ready 0102 Details Automatic start is not possible as the NC is not ready. Remedy ...
I Alarms Stop Codes (T) I - 14 T01 Cycle st prohibit(Battery alm) 0116 Details Automatic start is not possible because the voltage of the battery in the NC control unit hasdropped. Remedy - Replace the battery of the NC control unit.- Contact the service center. T01 R-pnt offset value not set 0117 D...
I Alarms Stop Codes (T) I - 15 T02 S/W stroke end axis exists 0202 Details An axis is at the stored stroke limit. Remedy - Manually move the axis.- Correct the machining program. T02 Reset signal ON 0203 Details The reset has been entered. Remedy - The program execution position has returned to the ...
I Alarms Stop Codes (T) I - 16 T04 Collation stop 0401 Details Collation stop occurred. Remedy - Execute the automatic start to resume the automatic operation. T10 Fin wait (Factors for waiting completion) Details The following Nos. are shown during the operation of the corresponding completion wait...
I Alarms Servo/Spindle Alarms (S) I - 18 0019 Detector commu err in syn cont Details An error of the shared detector on the machine side was detected on the secondary axis ofthe speed command synchronization control.- Servo stop method: Dynamic stop 001A Machine side dtc: Init comu er Details An err...
I Alarms Servo/Spindle Alarms (S) I - 20 0028 Machine side dtc: Error 6 Details An error was detected by the detector connected to the machine side.The error details are different according to the detector type.- Servo stop method: Dynamic stop- Spindle stop method: Coast to a stop[Detector alarm (S...
I Alarms Servo/Spindle Alarms (S) I - 21 002C Motor side dtc: Error 2 Details An error was detected by the detector connected to the motor side. The error details are different according to the detector type.- Servo stop method: Dynamic stop- Spindle stop method: Coast to a stop[Detector alarm (Serv...
I Alarms Servo/Spindle Alarms (S) I - 22 0035 NC command error Details The travel command data received from the NC was excessive.- Servo stop method: Deceleration stop enabled- Spindle stop method: Deceleration stop enabled 0036 NC-DRV commu: Commu error Details The communication with the NC was in...
I Alarms Servo/Spindle Alarms (S) I - 23 0046 Motor overheat Details Either the motor or the motor side detector detected an overheat.Or, the thermistor signal receiving circuit of the linear motor or DD motor was disconnected.Or, the thermistor signal receiving circuit was short-circuited.- Servo s...
I Alarms Servo/Spindle Alarms (S) I - 25 0080 Motor side dtc: cable err Details The cable type of the motor side detector cable is for rectangular wave signal.- Servo stop method: Initial error 0081 Machine side dtc: cable err Details The cable type of the machine side detector cable does not coinci...
I Alarms Servo/Spindle Alarms (S) I - 27 0077 Pw sply: Power module overheat Details Thermal protection function in the power module has started its operation. 3.2 Initial Parameter Errors (S02) 【 S022201-2456 】 S02 Initial parameter error:PR 2201-2456 (Axis name) Details The servo parameter setting...
I Alarms Servo/Spindle Alarms (S) I - 28 3.5 Servo Warnings (S52) Servo warning is displayed in the following format. Error No. consists of four digits (0096 to). Servo warnings are explained in ascending order of the error No.The four digits on the left part of each warning indicate the error No. (...
I Alarms Servo/Spindle Alarms (S) I - 29 00E6 Control axis detach warning Details A control axis is being detached. (State display)- Reset method: Automatically reset once the cause of the warning is removed. 00E7 In NC emergency stop state Details In NC emergency stop. (State display)- Stop method:...
I Alarms MCP Alarms (Y) I - 30 4. MCP Alarms (Y) Y02 System alm: Process time over 0050 Details System alarm: Process time is over. Remedy The software or hardware may be damaged. Contact the service center. (Note) When two or more "Y02 System alarms" occur at the same time, only the alarm w...
I Alarms MCP Alarms (Y) I - 32 Y03 Drive unit unequipped axis name Details The drive unit is not correctly connected. Alphabet (axis name): Servo axis drive unit not mounted 1 to 4: PLC axis drive unit not mounted S: No.1 spindle drive unit not mounted T: No.2 spindle drive unit not mounted M: No.3 ...
I Alarms MCP Alarms (Y) I - 33 Y07 Too many axes connected 00xy Details The number of axes connected to each channel exceeds the maximum number of connect-able axes. The exceeded number of axes per channel is displayed as alarm No. x: Exceeded number of axes at drive unit interface channel 2 (0 to F...
I Alarms MCP Alarms (Y) I - 34 Y20 Parameter compare error 0001 (Axis name) Details The speed monitoring parameter in the NC does not correspond to the parameter transmittedto the drive unit. The name of the axis with an error is displayed. Remedy The NC or the servo drive unit may be damaged.Contac...
I Alarms MCP Alarms (Y) I - 35 Y20 SDIO connector input volt err 0010 Details 24VDC power is not supplied to SDIO connector correctly. (SDIO 4A pin supply voltage wasdropped to 16V or less, or 1ms or more instant power interrupt was detected.) In this case, "Pw sply:Inst pw interpt(DC24V)" a...
I Alarms MCP Alarms (Y) I - 36 Y51 Parameter G1t1 illegal 0004 Details The time constant has not been set or exceeded the setting range. Remedy Correct "#2008 G1t1 (G1 time constant (primary delay)/Second-step time constant for soft ac-celeration/deceleration)". Y51 Parameter grid space ille...
I Alarms MCP Alarms (Y) I - 37 Y51 Values of PC1/PC2 too large 0101 Details The PC1 and PC2 settings for the rotary axis are too large. Remedy Correct "#2201 SV001 PC1 (Motor side gear ratio)" and "#2202 SV002 PC2 (Machine sidegear ratio)". Y90 No spindle signal 0001-0007 Details The...
I Alarms System Alarms (Z) I - 39 Z35 Direct Socket timeout error 0004 Details There was no response from client computers, and a timeout error occurred. Remedy Check the connection of the network cables, and check for broken wires and a failure of the network connection devices such as hub. Z35 Dir...
I Alarms System Alarms (Z) I - 40 Z55 RIO communication stop Details An error occurs in the communication between the control unit and remote I/O unit. Disconnection of a cableFault in remote I/O unitFault of power supply to remote I/O unit The alarm and the I/O unit No. is displayed when an error o...
I Alarms System Alarms (Z) I - 41 Z60 Fieldbus communication error n1 n2 n3 n4 Details A communication error has occurred on the Fieldbus communication with HN571/HN573/HN575. [n1 :Shows state of the master channel (shown in hexadecimal number)]00 :Offline In initializing40 :Stop Cutting I/O communi...
I Alarms System Alarms (Z) I - 43 Z83 NC started during SP rotation 0001 Details The NC was started while the spindle was rotating. Remedy Turn the power OFF and confirm that the spindle is not rotating, then turn the power ON again.
I Alarms Absolute Position Detection System Alarms (Z7*) I - 44 6. Absolute Position Detection System Alarms (Z7*) Z70 Abs posn base set incomplete 0001 (Axis name) Details Zero point initialization is incomplete. Otherwise, the spindle was removed. Remedy Complete zero point initialization. (Note) ...
I Alarms Absolute Position Detection System Alarms (Z7*) I - 45 Z70 Abs posn error(servo alm E3) 0106 (Axis name) Details The servo alarm No. E3 was displayed and the power was turned ON again. Remedy Perform zero point initialization again. (Note) To release alarm "Z70 Abs data error", ente...
I Alarms Distance-coded Reference Scale Errors (Z8*) I - 46 7. Distance-coded Reference Scale Errors (Z8*) Z80 Basic position lost 0001 Details The basic point data saved in the NC has been damaged. Remedy - Set the parameters. If the basic point data is not restored by setting the parameters, perfo...
I Alarms Emergency Stop Alarms (EMG) I - 48 EMG Emergency stop XTEN Details The CC-Link card is operating incorrectly. Switch/parameter settings for the CC-Link card are incorrect. Remedy - Replace the CC-Link card. - Correct the switch/parameter settings for the CC-Link card. EMG Emergency stop LAD...
I Alarms Auxiliary Axis Alarms I - 49 9. Auxiliary Axis Alarms 9.1 Auxiliary Axis Servo Errors/Warnings (S) S01 Aux ax PCB err (Drive circuit) 0011 (Axis No. 1 to 4) Details An error occurred in the drive unit's internal PCB. Remedy - Replace servo drive unit. S01 Aux ax S/W processing error 0013 (A...
I Alarms Auxiliary Axis Alarms I - 50 S02 Aux ax PCB error(LSI err) 0018 (Axis No. 1 to 4) Details An error occurred in the drive unit's internal LSI. Remedy - Replace servo drive unit. S02 Aux ax detector error 0020 (Axis No. 1 to 4) Details An error occurred in the communication between the servo ...
I Alarms Auxiliary Axis Alarms I - 51 S03 Aux ax excessive error 0052 (Axis No. 1 to 4) Details A position deflection exceeding the excessive error detection setting value occurred. Remedy - Increase the acceleration/ deceleration time constant.- Increase the torque limit value.- Review the power fa...
I Alarms Auxiliary Axis Alarms I - 52 9.3 Auxiliary Axis Operation Errors (M) M00 Aux ax dog overrun 0001 (Axis No. 1 to 4) Details When executing dog-type reference position, the zero point return speed is too fast or the doglength is too short. Remedy - Lower the zero point return speed or increas...
I Alarms Auxiliary Axis Alarms I - 53 M01 Aux axis changeover error 0166 (Axis No. 1 to 4) Details One of the following attempts was made on an axis that can be switched to NC/auxiliary axis. - A command was issued to an auxiliary axis from machining program. - When there were more than one NC axis ...
I Alarms Computer Link Errors (L) I - 55 10. Computer Link Errors (L) L01 Serial port being used -2 Details Serial port has already been opened or cannot be used. Remedy - Set the port not to shared by Anshin-net and so on. - Correct the parameter settings for tape operation port. L01 Timeout error ...
I Alarms User PLC Alarms (U) I - 56 11. User PLC Alarms (U) (Note) For details of user PLC alarms (U), refer to the PLC Programming Manual. U01 No user PLC - - Details PLC program is not input. (Note 1) The number of PLC program steps displayed on the screen may not match the actual number of error ...
I Alarms User PLC Alarms (U) I - 57 U10 Illegal PLC 0x800x Number of PLC program steps Details Software exceptionAn abnormal stop occurred in PLC program process due to a bus error, etc. bit0: BIN command operation error bit1: BCD command operation error (Note) The number of PLC program steps displa...
I Alarms Program Errors (P) I - 60 P38 No spec: Add. Op block skip Details "/n" has been issued while the optional block skip addition is not in the specifications. Remedy - Check the specifications. P39 No specifications Details - A non-specified G code was commanded. - The selected operati...
I Alarms Program Errors (P) I - 61 P71 Arc center error Details - An arc center cannot be obtained in R-specified circular interpolation. - A curvature center of the involute curve cannot be obtained. Remedy - Correct the numerical values of the addresses in the program. - Correct the start and end ...
I Alarms Program Errors (P) I - 62 P112 Plane selected while R compen Details - Plane selection commands (G17, G18, G19) were issued while tool radius compensation (G41, G42) and nose R compensation (G41, G42, G46) commands were being issued. - Plane selection commands were issued after completing n...
I Alarms Program Errors (P) I - 63 P132 Spindle rotation speed S=0 Details No spindle rotation speed command has been issued. Remedy - Correct the program. P133 Illegal P-No. G96 Details The illegal No. was specified for the constant surface speed control axis. Remedy - Correct the parameter setting...
I Alarms Program Errors (P) I - 64 P157 R compen direction changed Details During G46 nose R compensation, the compensation direction is reversed. Remedy - Change the G command to that which allows the reversed compensation direction (G00, G28, G30, G33, or G53). - Change the tool to that which has ...
I Alarms Program Errors (P) I - 67 P230 Subprogram nesting over Details Over 8 times of subprogram calls have been done in succession from a subprogram. - A M198 command was found in the program in the data server. - The program in the IC card has been called more than once (the program in the IC ca...
I Alarms Program Errors (P) I - 68 P262 Illegal modal (Coord rot) Details A coordinate rotation command has been issued during modal in which coordinate rotation isnot allowed. Remedy - Correct the program. P270 No spec: User macro Details A macro specification was commanded though it is out of spec...
I Alarms Program Errors (P) I - 72 P450 No spec: Chuck barrier Details The chuck barrier on command (G22) was specified although the chuck barrier is out of spec-ifications. Remedy - Check the specifications. P451 No spec: Stroke chk bef travel Details Stroke check before travel (G22/G23) was comman...
I Alarms Program Errors (P) I - 73 P485 Illegal modal (mill) Details - The milling mode was turned ON during nose R compensation or constant surface speed control. - A T command was issued during the milling mode. - The mode was switched from milling to cutting during tool compensation. - Cylindrica...
I Alarms Program Errors (P) I - 75 P605 T & TLM command in a block Details The T code is in the same block as the automatic tool length measurement block. Remedy - Specify the T code before the automatic tool length measurement block. P606 T cmnd not found before TLM Details The T code was not y...
I Alarms Program Errors (P) I - 76 P921 Illegal G code at 3D coord Details The commanded G code cannot be performed during 3-dimensional coordinate conversionmodal. Remedy - Refer to "MITSUBISHI CNC 700/70 Series Programming Manual (Machining Center Sys- tem)" for usable G commands. - When t...
I Alarms Program Errors (P) I - 77 P953 Tool axis dir cntrl prohibited Details Tool axis direction control was commanded during the mode where the control is unavailable. Remedy - Check the program and see whether any unavailable mode is included during tool axis di- rection control. If any, cancel ...
II Parameters User Parameters II - 1 1. User Parameters The parameters with "(PR)" requires the CNC to be turned OFF after the settings. Turn the power OFF andON to enable the parameter settings. (Note) This parameter description is common for M700V/M70V/E70 Series. It is written on the assu...
II Parameters User Parameters II - 2 【 #8011 】 INC. MAX. (for L system only) Set the maximum value for when inputting the tool wear compensation amount in the incremental mode. A value exceeding this setting value cannot be set. Absolute value of the input value is set. (If a negative value is input...
II Parameters User Parameters II - 3 【 #8019 】 R COMP Set a compensation coefficient for reducing a control error in the reduction of a corner roundness and arc radius. The larger the set value is, the smaller the theoretical error will be. However, since the speed at the corner goes down, the cycle...
II Parameters User Parameters II - 4 【 #8021 】 COMP_CHANGE Select whether to share or separate the compensation coefficient at the corner/curve during the high-accuracy control mode. 0: Share ("#8019 R COMP" is applied.)1: Separate - Corner : #8022 CORNER COMP- Curve : #8023 CURVE COMP(Note)...
II Parameters User Parameters II - 5 【 #8033 】 Fairing ON (for M system only) Select whether to use the fairing function. 0: Not use1: Use Fairing function is enabled during G61.2 modal, regardless of this setting. 【 #8034 】 AccClamp ON (for M system only) Select the method for clamping the cutting ...
II Parameters User Parameters II - 6 【 #8056 】 G74 RETRACT Set the amount of retract (amount of cut-up) of the cutting-off cycle (G74, G75). ---Setting range--- 0 to 999.999 (mm) 【 #8057 】 G76 LAST-D Set the amount of final cut-in by the compound type thread cutting (G76). ---Setting range--- 0 to 9...
II Parameters User Parameters II - 7 【 #8083 】 G83S modeM (for M system only) Set the M command code for changing to the small diameter deep hole drilling cycle mode. ---Setting range--- 1 to 99999999 【 #8084 】 G83S Clearance (for M system only) Set the clearance amount for the small diameter deep h...
II Parameters User Parameters II - 8 【 #8106 】 G46 NO REV-ERR (for L system only) Select the control for the compensation direction reversal in G46 (nose R compensation). 0: An alarm will be output and operation will stop when the compensation direction is reversed (G41 -> G42' G42 -> G41). 1:...
II Parameters User Parameters II - 10 【 #8156 】 Fine thread cut E Select the address E type when cutting an inch screw. (The same value as "#1229 set01/bit1" will be reflected. When either setting changes, the other will change accordingly.) 0: Specify the number of threads per inch for inch...
II Parameters User Parameters II - 11 【 #8205 】 OT-CHECK-P Set the coordinates of the (+) direction in the movable range of the stored stroke limit II or the upper limit coordinates of the prohibited range of stored stroke limit IIB. ---Setting range--- -99999.999 to 99999.999 (mm) 【 #8206 】 TOOL CH...
II Parameters User Parameters II - 12 【 #8216 】 Type in G28 return Select the performance after establishing the reference position in reference position return command. 0: Moves to the reference position.1: Won't move to the reference position. 【 #8217 】 Check start point Set a drawing start positi...
II Parameters User Parameters II - 13 【 #8306 】 P6 (for L system only) Set the area of the chuck and tail stock barrier. Set the coordinate from the center of workpiece (P0) for X-axis. (radius value) Set the coordinate value by basic machine coordinate system for Z-axis. ---Setting range--- -99999....
II Parameters User Parameters II - 15 【 #8707 】 Skip past amout (H) Set the difference (horizontal axis direction) between the skip read value and actual skip position. ---Setting range--- -99999.999 to 99999.999 (mm) 【 #8708 】 Skip past amout (V) Set the difference (vertical axis direction) between...
II Parameters User Parameters II - 17 【 #8888 】 Subbro stor D4: dev Select the storage destination (device) for the subprogram. M:Memory, G:HD(Note), F:FD(Note), R:Memory card, D:Data server(Note)(Note) This is available only with M700/M700VW Series. When D4 is designated at a subprogram call, the s...
II Parameters User Parameters II - 18 【 #8903 】 Counter type 3 Set the type of counter displayed at the upper right of the AUTO/MDI display on the Monitor screen. 1: Current position 2: Workpiece coordinate position 3: Machine position 4: Program position 8: Remain command 9: Manual interrupt amount...
II Parameters User Parameters II - 19 【 #8909(PR) 】 Aut/Manual switch Select the counter display method on Monitor screen. 0: "AUTO/MDI" and "Manual" display is switched by the mode selection switch. 1: Display AUTO/MDI counter only. 2: Display Manual counter only. 3: Display the enl...
II Parameters User Parameters II - 20 【 #8920 】 3D tool ofs select Select the method to calculate the drawing position when drawing a solid. With 3D drawing, the drawing position (tool tip position) is calculated with the method designated with this parameter, and the image is drawn. 0: For tool rad...
II Parameters User Parameters II - 21 【 #8927 】 SP on 3rd part sys Set a spindle No. to be displayed on the 3rd part system window when 2-part system simultaneous display is valid. On the 15-type display, 1-part system display can be also specified. High-order: Select an upper side spindle No.Low-or...
II Parameters User Parameters II - 22 【 #8934 】 Disable wear comp Select whether to disable the setting of tool wear compensation amount. 0: Not disable 1: Disable The wear compensation amount covers the following data according to the tool compensation type. - Compensation type I ("1" in ...
II Parameters User Parameters II - 25 【 #9018 】 HANDY TERMINAL DEV. Select the device No. used for communication with a handy terminal. (The device Nos. correspond to the input/output device parameters.) ---Setting range--- 0 to 4 【 #9051 】 Data I/O port Select whether to use display side serial por...
II Parameters User Parameters II - 26 【 #9105 】 DEV0 EVEN PARITY Select odd or even when parity is added to the data. This parameter is ignored when no parity is added. 0: Odd parity1: Even parity 【 #9106 】 DEV0 CHR. LENGTH Set the length of the data bit.Refer to "#9104 DEV0 PARITY CHECK". 0...
II Parameters User Parameters II - 27 【 #9119 】 DEV0 INPUT TYPE Select the mode for input (verification). 0: Standard input (Data from the very first EOB is handled as significant information.)1: EOBs following the first EOB of the input data are skipped until data other than EOB is input 【 #9120 】 ...
II Parameters User Parameters II - 28 【 #9201 】 DEV1 DEVICE NAME Set the device name corresponding to the device No.Set a simple name for quick identification. ---Setting range--- Use alphabet characters, numerals and symbols to set a name within 3 characters. 【 #9202 】 DEV1 BAUD RATE Select the ser...
II Parameters User Parameters II - 29 【 #9213 】 DEV1 EIA OUTPUT Select ISO or EIA code for data output. In data input mode, the ISO and EIA codes are identified automatically. 0: ISO code output1: EIA code output 【 #9214 】 DEV1 FEED CHR. Set the length of the tape feed to be output at the start and ...
II Parameters User Parameters II - 30 【 #9224 】 DEV1 EIA CODE * Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the special code "*". When output with EIA code, data can be output using the alternate code in which the special ISO code, not included in EIA, i...
II Parameters User Parameters II - 32 【 #9320 】 DEV2 OUT BUFFER Select the buffer size of the output data which is output to output device using NC side serial port. If the output device has a transmission error (overrun error), decrease the buffer size with this parameter. If the buffer size is dec...
II Parameters User Parameters II - 34 【 #9414 】 DEV3 FEED CHR. Set the length of the tape feed to be output at the start and end of the data during tape output. ---Setting range--- 0 to 999 (characters) 【 #9415 】 DEV3 PARITY V Select whether to perform the parity check for the number of characters i...
II Parameters User Parameters II - 35 【 #9425 】 DEV3 EIA CODE = Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the special code "=". When output with EIA code, data can be output using the alternate code in which the special ISO code, not included in EIA, i...
II Parameters User Parameters II - 37 【 #9520 】 DEV4 OUT BUFFER Select the buffer size of the output data which is output to output device using NC side serial port. If the output device has a transmission error (overrun error), decrease the buffer size with this parameter. If the buffer size is dec...
II Parameters User Parameters II - 38 【 #9601 】 BAUD RATE Select the rate at which data is transferred. 0: 19200 (bps)1: 96002: 48003: 24004: 12005: 6006: 3007: 1108: 38400 【 #9602 】 STOP BIT Select the stop bit length used in the start-stop system. Refer to "#9603 PARITY EFFECTIVE". At the ...
II Parameters User Parameters II - 39 【 #9610 】 LINK PARAM. 2 Bit 2: Specify the control code parity (even parity for the control code). Select whether to add an even parity to the control code, in accordance with the I/O device specifications. 0: Not add a parity bit to the control code 1: Add a pa...
II Parameters User Parameters II - 40 【 #9706 】 Host No. Select the No. of the host to be used from host 1 to host 4. ---Setting range--- 1 to 4 : Host No. 【 #9711 】 Host1 host name Set the host computer name. This parameter allows the NC to easily recognize the host computer on the network. Set the...
II Parameters User Parameters II - 41 【 #9720 】 Host 1 Wrd num: cmnt Set the number of words to be displayed as a comment. (Note) One word designates a character string divided by one or more spaces. ---Setting range--- 0 to 1000: Default value 【 #9721 】 Host 1 no total siz Set whether to display th...
II Parameters User Parameters II - 44 【 #9777 】 Host 4 Wrd pos: size Set the size display position (nth word from left) of the list displayed when the ftp command "dir" is executed. (Note) One word designates a character string divided by one or more spaces. ---Setting range--- 0 to 1000: De...
II Parameters User Parameters II - 45 【 #10501 - 10530(PR) 】 Monitr main menu 1 to 30 Set the menu Nos. to display the menu on Monitor screen's main menu using menu customization function. The menu position of each parameter and the menu when "0" is set are as follows.#10501: First from left...
II Parameters User Parameters II - 46 【 #10551 - 10580(PR) 】 Setup main menu 1 to 30 Set the menu Nos. to display the menu on Setup screen's main menu using menu customization function. The menu position of each parameter and the menu when "0" is set are as follows.#10551: First from left in...
II Parameters User Parameters II - 47 【 #10601 - 10630(PR) 】 Edit main menu 1 to 30 Set the menu Nos. to display the menu on Edit screen's main menu using menu customization function. The menu position of each parameter and the menu when "0" is set are as follows.#10601: First from left in t...
II Parameters Base Specifications Parameters II - 50 2. Base Specifications Parameters The parameters with "(PR)" requires the CNC to be turned OFF after the settings. Turn the power OFF andON to enable the parameter settings. (Note) This parameter description is common for M700V/M70V/E70 Se...
II Parameters Base Specifications Parameters II - 51 【 #1013(PR) 】 axname Axis name Set each axis' name with an alphabetic character. Use the characters X, Y, Z, U, V, W, A, B or C. (Note 1) Do not set the same name twice in one part system. The same name which is used in another part system can be ...
II Parameters Base Specifications Parameters II - 53 【 #1037(PR) 】 cmdtyp Command type Set the G code list and compensation type for programs. 1 : List1(for M) Type I (one compensation amount for one compensation No.)2 : List1(for M) Type II (shape and wear compensation amounts for one comp. No.)3 :...
II Parameters Base Specifications Parameters II - 54 【 #1044(PR) 】 auxno MR-J2-CT Connections Set the number of MR-J2-CTs connected. (Note) The number of MR-J2-CTs possible to connect and setting range are different according to the model.Check the specifications of each series. 【 #1050(PR) 】 MemPrg...
II Parameters Base Specifications Parameters II - 61 【 #1158 】 F0atno Not used. Set to "0". 【 #1163(PR) 】 No rio RIO connection detection invalid Select whether to enable or disable RIO connection detection. 0: Enable1: Disable If your I/O consists of only cards such as CC-LINK, setting this...
II Parameters Base Specifications Parameters II - 62 【 #1175 】 skip1 G31.1 skip condition Designate the skip signal in multi-step skip G31.1.The setting method is same as "#1173". 【 #1176 】 skip1f G31.2 skip speed Set the skip feedrate in multi-step skip G31.1. ---Setting range--- 1 to 99999...
II Parameters Base Specifications Parameters II - 63 【 #1188 】 spd_F4 F1 digit feedrate F4 Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1"). Feedrate when F4 is issued (mm/min) When "#1246 set08/bit6" is set to "1" and F 1-di...
II Parameters Base Specifications Parameters II - 64 【 #1200(PR) 】 G0_acc Validate acceleration and deceleration with inclination constant G0 Select the acceleration and deceleration type when a rapid traverse command is issued. 0: Acceleration and deceleration with constant time (conventional type)...
II Parameters Base Specifications Parameters II - 65 【 #1210 】 RstGmd Modal G code reset Select whether to initialize G code group modals and H and D codes, which corresponds to bits as follows, when the system is reset. 0: Initialize.1: Not initialize. <Description of bits for M system> bit 1...
II Parameters Base Specifications Parameters II - 67 【 #1213(PR) 】 proaxy Side 1 of inclination angle (for L system only) Set the length within the orthogonal coordinate of the inclined axis, a side of the triangle formed with the inclination angle. ---Setting range--- -9999.999 to 9999.999 【 #1214(...
II Parameters Base Specifications Parameters II - 68 【 #1219 】 aux03 bit1: Stop high-speed PC monitoring function Set "1" to disable the function that triggers the emergency stop when the PC high-speed processing time is extended. Disable the monitoring function only as a temporary measure. ...
II Parameters Base Specifications Parameters II - 83 【 #1280(PR) 】 ext16 bit0: I/F per axis during mixed control (cross axis control) Select how to handle the following PLC interface for axes interchanged with the mixed control (cross axis control).- Mirror image- Manual/automatic interlock- Manual/...
II Parameters Base Specifications Parameters II - 88 【 #1312 】 T_base Tool life management standard number Set the standard No. for the tool life management. When the value specified by the T code command exceeds the set value in this parameter, the set value will be subtracted from the command valu...
II Parameters Base Specifications Parameters II - 89 【 #1331(PR) 】 MC_dp2 Contactor weld detection device 2 When safety observation is executed, set the remote I/O device to input the contactor's auxiliary b contact signal used for the contactor weld detection. If "0" is set, weld detection ...
II Parameters Base Specifications Parameters II - 90 【 #1342 】 AlmDly Alarm display delay time Set a time between when an operation alarm occurs and when the alarm display and signal turn ON.When set to "0", the alarm display and signal will turn ON immediately after the alarm occurrence.Whe...
II Parameters Base Specifications Parameters II - 91 【 #1401 】 M_mode M command operation selection Select the M command operation.(Note) Register M codes in the special operation registration M codes (#1411 to #1418). 0: Not wait for the completion of registered M codes, but wait for the completion...
II Parameters Base Specifications Parameters II - 92 【 #1418 】 M_wait[M255-224] Special operation registration M code Register an M code (224 to 255) that needs special operation.Each bit of the setting value corresponds to the M code number.(Example) To register M05, set 00000020 in #1411.(Note) No...
II Parameters Base Specifications Parameters II - 93 【 #1511 】 DOORPm Signal input device 1 for door interlock II: for each part system Set the fixed device number (X??) for door interlock II signal input for each part system.A device number from X01 to XFF can be specified.(Except X100.)Device numb...
II Parameters Base Specifications Parameters II - 94 【 #1523 】 C_feed Normal line control axis turning speed Set the turning speed of the normal line control axis at the block joint during normal line control.Set a value that does not exceed the normal line control axis' clamp speed ("#2002 clam...
II Parameters Base Specifications Parameters II - 95 【 #1542 】 crsax[6] Set the axis to be interchanged during the mixed control (cross axis control).Using two digits, set the name of the axis to be interchanged with the axis in the part system where the mixed control (cross axis control) request si...
II Parameters Base Specifications Parameters II - 96 【 #1570 】 Sfilt2 Soft acceleration/deceleration filter 2 Set the filter time constant for smoothly changing the acceleration rate in pre-interpolation acceleration/deceleration. This will be disabled when "0" or "1" is set. ---Sett...
II Parameters Base Specifications Parameters II - 97 【 #1590 】 Animate ax direct Machine status animated display axis direction(+/-) <bit0> 0: 1st axis + direction is set to the right direction.1: 1st axis + direction is set to the left direction. <bit1> 0: 2nd axis + direction is set to...
II Parameters Base Specifications Parameters II - 98 【 #1928(PR) 】 Global Gateway Gateway Set the IP address for the gateway. 【 #1929 】 Port number Port No. Set the port No. for the service function. ---Setting range--- 1 to 9999(Set 2000 when not connected to the Ethernet.) 【 #1930(PR) 】 Host addre...
II Parameters Base Specifications Parameters II - 99 【 #11009(PR) 】 M2 label O M2 label O Select the program number label when using the M2 format. 0: Label L1: Label O 【 #11010(PR) 】 Software keyboard Software keyboard Select with touch panel whether to use software keyboard. 0: Do not use1: Use2: ...
II Parameters Base Specifications Parameters II - 100 【 #11022 】 SRAM Output Type SRAM output type Set the SRAM output type.(Note) In M700 Series, the conventional SRAM output type is set regardless of the setting of this parameter. 0: The latest SRAM output type is set. (Not compatible with F3 and ...
II Parameters Base Specifications Parameters II - 101 【 #11035 】 Sys. change limit Part system switching restriction This restricts switching the part systems displayed on screen. 0: Not restrict1: Disable the part system switching by pressing [$<->$] key on touch panel.2: Disable the part sys...
II Parameters Base Specifications Parameters II - 102 【 #12001 】 ManualB RectanA xH Manual feed rate B constant surface control intersecting part system axis name (horizontal) Set the part system axis name ("#1013 axname") for the two axes that intersect with the rotary axis direction. When ...
II Parameters Base Specifications Parameters II - 103 【 #12010(PR) 】 Tbin T binary Data type 0 BCDData type 1 Unsigned binaryData type -1 Singed binary <For unsigned binary>The absolute value "1" is output for "-1".<For singed binary>"-1" is output as "0xFFFFF...
II Parameters Axis Specifications Parameters II - 104 3. Axis Specifications Parameters The parameters with "(PR)" requires the CNC to be turned OFF after the settings. Turn the power OFF andON to enable the parameter settings. (Note) This parameter description is common for M700V/M70V/E70 S...
II Parameters Axis Specifications Parameters II - 105 【 #2004 】 G0tL G0 time constant (linear) Set a linear control time constant for rapid traverse acceleration and deceleration.The time constant will be enabled when LR (rapid traverse feed with linear acceleration/deceleration) or F (soft accelera...
II Parameters Axis Specifications Parameters II - 107 【 #2014 】 OT + Soft limit I + Set a soft limit area with reference to the zero point of the basic machine coordinate. Set the coordinate in the positive direction for the movable area of stored stroke limit 1. The coordinate in the negative direc...
II Parameters Axis Specifications Parameters II - 108 【 #2023 】 ozfmin Set up ATC speed lower limit Set the minimum speed outside the soft limit range during the second to the fourth reference position return. ---Setting range--- 0 to 1000000 (mm/min) 【 #2024 】 synerr Allowable error Set the maximum...
II Parameters Axis Specifications Parameters II - 109 【 #2030(PR) 】 dir (-) Reference position direction (-) Select which side of the near-point dog the reference position is established.For a rotary axis, select a direction that heads to the zero point from the intermediate point during automatic z...
II Parameters Axis Specifications Parameters II - 110 【 #2036 】 slv_adjust Reference position adjustment value Set the distance from the first grid point after leaving the near point dog on the secondary axis to the position where the reference position is actually established in dog-type reference ...
II Parameters Axis Specifications Parameters II - 111 【 #2038 】 #2_rfp Reference position #2 Set the position of the second reference position from the zero point of the basic machine coordinate. ---Setting range--- -99999.999 to 99999.999 (mm) 【 #2039 】 #3_rfp Reference position #3 Set the position...
II Parameters Axis Specifications Parameters II - 113 【 #2068 】 G0fwdg G00 feed forward gain Set a feed forward gain for G00 pre-interpolation acceleration/deceleration. The larger the setting value, the shorter the positioning time during in-position checking. If a machine vibration occurs, set the...
II Parameters Axis Specifications Parameters II - 116 【 #2103 】 skip_t1 Skip time constant primary delay / Second-step time constant for soft acceleration/deceleration Set a primary-delay time constant for variable speed skip acceleration and deceleration, or for an occasion where a skip command iss...
II Parameters Axis Specifications Parameters II - 118 【 #2132 】 vback pos1 Variable backlash compensation amount changeover end point position 1 Set the range of the center of the end point position.(The range less than position 1 is the - range, and the range exceeding position 2 is the + range.)Th...
II Parameters Axis Specifications Parameters II - 119 【 #2140(PR) 】 Ssc Svof Filter Speed monitor Error detection time during servo OFF Set the error detection time of command speed monitoring and feedback speed monitoring during servo OFF.An alarm will occur if the time, for which the speed has bee...
II Parameters Axis Specifications Parameters II - 120 【 #2144 】 baseps Base machine coordinate zero point relative distance Set each axis's position of the base machine coordinate zero point when an arbitrary point M on the machine is regarded as a base point.Unify the directions of all part systems...
II Parameters Axis Specifications Parameters II - 121 【 #2148 】 Blf_E1 Reference amount of position-dependent increasing-type backlash compensation 1 Set the compensation amount for specifying the compensation change rate in position-dependent increasing-type backlash compensation. When "#2148 B...
II Parameters Axis Specifications Parameters II - 122 【 #2152 】 acc_rate Acceleration rate in proportion to the maximum acceleration rate Set the rate in proportion to the maximum acceleration rate in rapid traverse.(Note) If this parameter is set to "0" or "100", constant inclinatio...
II Parameters Axis Specifications Parameters II - 123 【 #2174 】 LmccQR Lost motion compensation 3 viscous coefficient for high-speed retract Set the machine system's viscous coefficient when using lost motion compensation type 3 in drilling cycle at high-speed retract. When set to "0", the p...
II Parameters Axis Specifications Parameters II - 124 【 #2199 】 G1tMin Minimum time constant for cutting feed constant inclination acc./dec. Acceleration/Deceleration is carried out so that the acceleration/deceleration time will not become longer than this parameter's setting when the acceleration/...
II Parameters Axis Specifications Parameters II - 125 【 #2569 】 VBL2 BL01 Variable backlash comp II Comp data at changeover spd 2 and stroke pos 1 Set the compensation data (backlash amount) at changeover speed 2 and stroke position 1. Calculate the current compensation data according to the current...
II Parameters Servo Parameters II - 127 4. Servo Parameters The parameters with "(PR)" requires the CNC to be turned OFF after the settings. Turn the power OFF andON to enable the parameter settings. (Note) This parameter description is common for M700V/M70V/E70 Series. It is written on the ...
II Parameters Servo Parameters II - 129 【 #2216 】 SV016 LMC1 Lost motion compensation 1 Set this parameter when the protrusion (that occurs due to the non-sensitive band by friction, torsion, backlash, etc.) at quadrant change is too large. This sets the compensation torque at quadrant change (when ...
II Parameters Servo Parameters II - 130 【 #2217(PR) 】 SV017 SPEC1 Servo specification 1 Select the servo specifications. A function is allocated to each bit. Set this in hexadecimal format. bit F-C : spm Motor series selection 0: Not used 1: 200V HF, HP motor (Standard) 2: Not used 3: 400V HF-H, HP-...
II Parameters Servo Parameters II - 132 【 #2225(PR) 】 SV025 MTYP Motor/Detector type Set the position detector type, speed detector type and motor type. The setting value is a four-digit hex (HEX). bit F-C : pen(HEX-4) Position detector Semi-closed loop control by general motor pen=2 Full-closed loo...
II Parameters Servo Parameters II - 133 【 #2227 】 SV027 SSF1 Servo function 1 Select the servo functions. A function is assigned to each bit. Set this in hexadecimal format. bit F : Not used. Set to "0". bit E : zrn2 Set to "1". (Fixed) bit D : Not used. Set to "0". bit C : N...
II Parameters Servo Parameters II - 134 【 #2228(PR) 】 SV028 MSFT Magnetic pole shift amount (for linear/direct-drive motor) Set this parameter to adjust the motor magnetic pole position and detector's installation phase when using linear motors or direct-drive motors. During the DC excitation of the...
II Parameters Servo Parameters II - 135 【 #2233 】 SV033 SSF2 Servo function 2 Select the servo functions. A function is assigned to each bit. Set this in hexadecimal format. bit F : lmc2a Lost motion compensation 2 timing 0: Normal 1: Change bit E : zup Vertical axis pull up function 0: Stop 1: Enab...
II Parameters Servo Parameters II - 136 【 #2234 】 SV034 SSF3 Servo function 3 Select the servo functions. A function is assigned to each bit. Set this in hexadecimal format. bit F-C: ovsn Overshooting compensation type 3 Non-sensitive band Set the non-sensitive band of the model position droop overs...
II Parameters Servo Parameters II - 137 【 #2235 】 SV035 SSF4 Servo function 4 Select the servo functions. A function is assigned to each bit. Set this in hexadecimal format. bit F : clt Inertia ratio display 0: Setting for normal use 1: Display the total inertia ratio estimated at acceleration/decel...
II Parameters Servo Parameters II - 138 【 #2236(PR) 】 SV036 PTYP Power supply type/ Regenerative resistor type MDS-D2/DH2 Series: Power supply type When connecting a power supply unit, set a code for each power supply unit. bit F-C : amp Set the power backup function to be used. No function used : 0...
II Parameters Servo Parameters II - 139 MDS-DJ-V1/V2 Series: Regenerative resistor type Set the regenerative resistor type. bit F-8 : amp(bit F-C) / rtyp(bit B-8) Resistor built-in drive unit : 10Setting prohibited : 11MR-RB032 : 12MR-RB12 or GZG200W39OHMK : 13MR-RB32 or GZG200W120OHMK 3 units conne...
II Parameters Servo Parameters II - 143 【 #2263 】 SV063 DA1MPY D/A output ch1 output scale / Initial DC excitation time Set output scale of the D/A output channel 1 in increment of 1/100. When "0" is set, the magnification is the same as when "100" is set. When the DC excitation is r...
II Parameters Servo Parameters II - 144 【 #2282 】 SV082 SSF5 Servo function 5 Select the servo functions. A function is assigned to each bit. Set this in hexadecimal format. bit F-C : dis Digital signal input selection 0: No signal 1: SLS (Safely Limited Speed) function door state signal 2: Battery ...
II Parameters Servo Parameters II - 145 【 #2283 】 SV083 SSF6 Servo function 6 Select the servo functions. A function is assigned to each bit. Set this in hexadecimal format. bit F-8 : Not used. Set to "0". bit 7-5 : nfd5 Depth of Notch filter 5 Set the depth of Notch filter 5 (SV088). bit7,6...
II Parameters Servo Parameters II - 146 【 #2286 】 SV086 LMCc Lost motion compensation 3 viscous coefficient Set the machine system's viscous coefficient when selecting lost motion compensation type 3. When not using, set to "0". Related parameters: SV016, SV041, SV082/bit2,1, SV086 ---Settin...
II Parameters Servo Parameters II - 147 【 #2295 】 SV095 ZUPD Vertical axis pull up distance Set this parameter to adjust the pull up distance when the vertical axis pull up function is enabled. When the pull up function is enabled and this parameter is set to "0", for a rotary motor, 8/1000 ...
II Parameters Servo Parameters II - 148 【 #2306 】 SV106 PGM OMR-FF scale model gain Set the scale model gain (position response) in OMR-FF control.Set the same value as SV003(PGN1).Increase the setting value to perform a high-speed machining such as a fine arc or to improve the path error.Lower the ...
II Parameters Servo Parameters II - 149 【 #2314 】 SV114 SSF9 Servo function 9 Select the servo functions. A function is assigned to each bit. Set this in hexadecimal format. bit F-9 : Not used. Set to "0". bit 8 : nohis History of communication error alarm between NC and DRV (34, 36, 38, 39)...
II Parameters Servo Parameters II - 150 【 #2315 】 SV115 SSF10 Servo function 10 Select the servo functions. A function is assigned to each bit. Set this in hexadecimal format. bit F : are Notch filter5 all frequencies adapted When enabled, Notch filter5 all frequencies adaptive range is not limited ...
II Parameters Servo Parameters II - 151 【 #2318(PR) 】 SV118 RNG2ex Expansion main side detector resolution When using high-accuracy binary resolution detector, set the number of pulses to four bite data of SV118 (high-order) and SV020 (low-order) by pulse(p). When SV118=0, the setting unit of SV020 ...
II Parameters Servo Parameters II - 152 【 #2334 】 SV134 RRn0 Distance-coded reference check / revolution counter Set this parameter to operate distance-coded reference check when using distance-coded reference scale. During the distance-coded reference check initial setup (SV137:RAER=-1), set the fo...
II Parameters Servo Parameters II - 153 【 #2438 】 SV238 SSCFEED Safely limited speed Set the machine's safely limited speed for the SLS (Safely Limited Speed) function. Set this parameter within the following setting ranges. For linear axis: 2000mm/min or less For rotary axis: 18000°/min (50r/min) o...
II Parameters Spindle Parameters II - 154 5. Spindle Parameters The parameters with "(PR)" requires the CNC to be turned OFF after the settings. Turn the power OFF andON to enable the parameter settings. (Note) This parameter description is common for M700V/M70V/E70 Series. It is written on ...
II Parameters Spindle Parameters II - 155 【 #3011 】 ssift 3 Shift rotation speed (Gear: 10) Set the spindle speed for gear shifting with gear 10.(Note) Setting too large value may cause a gear nick when changing gears. ---Setting range--- 0 to 32767 (r/min) 【 #3012 】 ssift 4 Shift rotation speed (Ge...
II Parameters Spindle Parameters II - 156 【 #3020 】 stapt 4 Synchronous tapping 1st step acceleration/deceleration time constant (Gear: 11) Set the time constant for synchronous tapping 1st step linear acceleration/deceleration control when gear 11 is selected. (linear acceleration/deceleration patt...
II Parameters Spindle Parameters II - 157 【 #3031(PR) 】 smcp_no Drive unit I/F channel No. (spindle) Set the interface channel No. of CNC control unit to which the spindle is connected and the axis No. within each channel.Set this parameter in 4-digit (hexadecimal) format. HEX-4 : Drive unit interfa...
II Parameters Spindle Parameters II - 161 【 #3069 】 symtm2 Phase synchronization end confirmation time Set a period of waiting time for spindle phase synchronization control's completion as a time in which the speed stays within the attainment range.When "0" is set, the time will be 500ms. W...
II Parameters Spindle Parameters II - 162 【 #3106 】 zrn_typ Zero point return specifications Select the zero point return specification.Functions are allocated to each bit.Set this in hexadecimal format. bit F : Spindle zero point detection with contactless switch 0: Normal 1: Enable spindle zero po...
II Parameters Spindle Parameters II - 163 【 #3109 】 zdetspd Z phase detection speed For the first S command after power is turned ON, the spindle rotates at the speed of setting value for this parameter until Z phase is detected twice.When "#3106/bitF = 1" (Spindle zero point proximity switc...
II Parameters Spindle Parameters II - 164 【 #3118 】 sp2_t4 Time constant in orientation/interpolation mode automatic reference position return (Gear: 11) Set the linear acceleration/deceleration time constant for zero point return control (#3106/bit4,8) which is automatically started at the time of ...
II Parameters Spindle Parameters II - 167 【 #13012 】 SP012 Not used. Set to "0". 【 #13013 】 SP013 Not used. Set to "0". 【 #13014 】 SP014 PY1 Minimum excitation rate 1 Set the minimum value for the variable excitation rate. The standard setting is "50". Set to "0" when...
II Parameters Spindle Parameters II - 168 【 #13018(PR) 】 SP018 SPEC2 Spindle specification 2 Select the spindle specification. A function is allocated to each bit. Set this in hexadecimal format. bit F-A : Not used. Set to "0". bit 9 : mpg Earth fault detection 0: Disable 1: Enable (standard...
II Parameters Spindle Parameters II - 170 【 #13032(PR) 】 SP032 PTYP Power supply type/ Regenerative resistor type MDS-D2/DH2 Series: Power supply type When connecting a power supply unit, set a code for each power supply unit. bit F-C : amp Set the power backup function to be used. No function used ...
II Parameters Spindle Parameters II - 171 MDS-DJ-SP Series: Regenerative resistor type Set the regenerative resistor type. bit F-8 : amp(bit F-C) / rtyp(bit B-8) Setting prohibited : 10-12MR-RB12 or GZG200W39OHMK : 13MR-RB32 or GZG200W120OHMK 3 units connected in parallel : 14MR-RB30 or GZG200W39OHM...
II Parameters Spindle Parameters II - 172 【 #13034 】 SP034 SFNC2 Spindle function 2 Select the spindle function. A function is allocated to each bit. Set this in hexadecimal format. bit F-D : nfd5 Depth of Notch filter 5 Set the depth of Notch filter 5 (SP088). bit F,E,D= 000: - ∞ 001: -18.1[dB] 010...
II Parameters Spindle Parameters II - 173 【 #13035(PR) 】 SP035 SFNC3 Spindle function 3 Select the spindle function. A function is allocated to each bit. Set this in hexadecimal format. bit F-D : Not used. Set to "0". bit C : shgn SHG control in interpolation mode 0: Stop 1: Start When using...
II Parameters Spindle Parameters II - 175 【 #13045 】 SP045 OBS1 Disturbance observer filter frequency Set the disturbance observer filter band. Normally, set to "100". To use the disturbance observer, also set SP037(JL), SP044(OBS2) and SP226/ bitE. When not using, set to "0". ---Set...
II Parameters Spindle Parameters II - 177 【 #13064(PR) 】 SP064 GRB4 Motor side gear ratio 4 Set the number of gear teeth on the motor side when "the gear selection command (control input 4/bit6, 5)" is set to "11". ---Setting range--- 1 to 32767 【 #13065 】 SP065 TLM1 Torque limit 1 S...
II Parameters Spindle Parameters II - 178 【 #13073 】 SP073 VGVN Variable speed gain target value If noise is bothersome during high speed rotation, it may be reduced by lowering the speed loop gain at high speed. Set this value to ensure the adequate response by suppressing noise and vibration at lo...
II Parameters Spindle Parameters II - 181 【 #13100 】 SP100 Not used. Set to "0". 【 #13101 】 SP101 TMA1 OMR-FF movement averaging filter time constant 1 Set the movement averaging filter time constant in OMR-FF control.The standard setting is "88".Set to "0" when not using OMR...
II Parameters Spindle Parameters II - 183 【 #13124 】 SP124 ILMTsp Magnetic pole detection current limit value Set the current limit value for the magnetic polar detection loop. This is used in the initial magnetic polar detection when the IPM spindle motor is turned ON. Set to "0" when using...
II Parameters Spindle Parameters II - 184 【 #13136(PR) 】 SP136 Set the unique constants for the spindle motor. (High-speed coil) The setting value is determined by the motor's mechanical and electrical characteristics and specifications, so normally set the value given in the spindle parameter list....
II Parameters Spindle Parameters II - 189 【 #13220 】 SP220 Not used. Set to "0". 【 #13221 】 SP221 Not used. Set to "0". 【 #13222 】 SP222 Not used. Set to "0". 【 #13223 】 SP223 Not used. Set to "0". 【 #13224 】 SP224 Not used. Set to "0". 【 #13225 】 SP225 SFNC5 ...
II Parameters Spindle Parameters II - 190 【 #13226 】 SP226 SFNC6 Spindle function 6 Select the spindle functions. Functions are allocated to each bit. Set this in hexadecimal format. bit F : clt Spindle monitor load inertia ratio 0: Normal 1: Display bit E : obs Disturbance observer 0: Normal 1: Ena...
II Parameters Spindle Parameters II - 191 【 #13229 】 SP229 SFNC9 Spindle function 9 Select the spindle functions. Functions are allocated to each bit. Set this in hexadecimal format. bit F : ssc SLS (Safely Limited Speed) function 0: Disable 1: Enable bit E : Not used. Set to "0". bit D : rp...
II Parameters Rotary Axis Configuration Parameters II - 194 6. Rotary Axis Configuration Parameters The parameters with "(PR)" requires the CNC to be turned OFF after the settings. Turn the power OFF andON to enable the parameter settings. (Note) This parameter description is common for M700...
II Parameters Rotary Axis Configuration Parameters II - 195 【 #7913 】 MCHN_SPEED_CTRL Machine speed fluctuation suppression Select whether to suppress the machine speed fluctuation due to rotary axis movement. 0: Not suppress 1: Suppress (Note)This parameter is disabled when SSS control is enabled. ...
II Parameters Machine Error Compensation Parameters II - 199 7. Machine Error Compensation Parameters The parameters with "(PR)" requires the CNC to be turned OFF after the settings. Turn the power OFF andON to enable the parameter settings. (Note) This parameter description is common for M7...
II Parameters Machine Error Compensation Parameters II - 200 【 #4009+10(n-1) 】 refcmp Reference position compensation amount <n-th axis> When two-way pitch error compensation is enabled, set the compensation amount of the reference position when the axis moves to the position from the opposite...
II Parameters PLC Constants II - 201 8. PLC Constants (Note) This parameter description is common for M700V/M70V/E70 Series. It is written on the assumption that all option functions are added.Confirm with the specifications issued by the machine tool builder before starting use.Some of the paramete...
II Parameters Macro List II - 204 9. Macro List (Note) This parameter description is common for M700V/M70V/E70 Series. It is written on the assumption that all option functions are added.Confirm with the specifications issued by the machine tool builder before starting use. 【 #7001 】 M[01] Code Set ...
II Parameters Macro List II - 207 【 #7102 】 M2mac Type Set the type for when calling out the macro with the 2nd miscellaneous command.The macro will be called out with the "#1170 M2name" address command when "#1198 M2mac" is set to “1”. 0: Equivalent to M98 P △△△△ ; 1: Equivalent to ...
II Parameters Macro List II - 210 【 #7291 】 G[10] Code Set the G code to be used when calling the macro with a G command.Do not set a G code used in the system.G101 to G110 and G200 to G202 are user macro I codes. However, if a parameter is set for the G code call code, the G code call will have the...
II Parameters Macro List II - 211 【 #7405 】 ASCII[01] Variable When the call type is "0", set the variable No. set after the ASCII code. ---Setting range--- 100 to 149 【 #7411 】 ASCII[02] Valid The ASCII code macro parameters (#7412 to 7415) are validated. 0: Invalid1: Valid 【 #7412 】 ASCII[...
II Parameters Position Switches II - 212 10. Position Switches (Note) This parameter description is common for M700V/M70V/E70 Series. It is written on the assumption that all option functions are added.Confirm with the specifications issued by the machine tool builder before starting use. 【 #7500 】 ...
II Parameters Position Switches II - 213 【 #7522 】 PSW3 dog1 Imaginary dog position 1 When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to the PLC.1st part system device: X1D022nd part system device: X1D22 ---Setting range--- -99999.999 to 99999.999 (mm) 【...
II Parameters Auxiliary Axis Parameters II - 222 11. Auxiliary Axis Parameters (Note) This parameter description is common for M700V/M70V/E70 Series. It is written on the assumption that all option functions are added.Confirm with the specifications issued by the machine tool builder before starting...
II Parameters Auxiliary Axis Parameters II - 223 【 #50009 】 Not used. Set to "0". 【 #50010 】 EMGt Deceleration control time constant Set the deceleration time from the clamp speed (Aspeed1). Set the same value as the acceleration/deceleration time constant used for the normal rapid traverse....
II Parameters Auxiliary Axis Parameters II - 224 【 #50024 】 DG2 Load inertia ratio Set the ratio of load inertia to motor inertia. Default value: 2.0 ---Setting range--- 0.0 to 50.0 (fold) 【 #50025 】 Not used. Set to "0". 【 #50030(PR) 】 MTY Motor type Set the motor type. When set to the defa...
II Parameters Auxiliary Axis Parameters II - 225 【 #50101(PR) 】 Cont1 Control parameter 1 The bits that are not explained here must be set to the default value. Default value : bit9 = “1“, Other bits =”0” bit1: 0: High-speed zero point return after the establishment of zero point1: Dog-type return f...
II Parameters Auxiliary Axis Parameters II - 226 【 #50104(PR) 】 tleng Linear axis stroke length Set the travel stroke length for linear axis. The set value for this parameter will be ignored when non-uniform assignments are set or random positions are commanded. Default value: 100.000 ---Setting ran...
II Parameters Auxiliary Axis Parameters II - 227 【 #50120 】 ABS Type Absolute position detection parameter The bits that are not explained here must be set to the default value. Default value : bit2 = “1“, Other bits =”0” bit1: 0: Dogless-type method initializing1: Dog-type method initializing bit2:...
II Parameters Auxiliary Axis Parameters II - 234 【 #50221 】 push.t1 Stopper standby time Set the standby time from the stopper starting coordinate positioning to the stopper operation start in the stopper positioning. Default value: 0 ---Setting range--- 0 to 9999 (ms) 【 #50222 】 push.t2 Stopper tor...
II Parameters Open Parameters II - 235 12. Open Parameters (Note) This parameter description is common for M700V/M70V/E70 Series. It is written on the assumption that all option functions are added.Confirm with the specifications issued by the machine tool builder before starting use. 【 #29001 】 Ope...
II Parameters Device Open Parameters II - 236 13. Device Open Parameters (Note) This parameter description is common for M700V/M70V/E70 Series. It is written on the assumption that all option functions are added.Confirm with the specifications issued by the machine tool builder before starting use. ...
II Parameters SRAM Open Parameters II - 237 14. SRAM Open Parameters (Note) This parameter description is common for M700V/M70V/E70 Series. It is written on the assumption that all option functions are added.Confirm with the specifications issued by the machine tool builder before starting use. 【 #4...
II Parameters CC-Link Parameters II - 238 15. CC-Link Parameters (Note) This parameter description is common for M700V/M70V/E70 Series. It is written on the assumption that all option functions are added.Confirm with the specifications issued by the machine tool builder before starting use. 【 #24001...
II Parameters CC-Link Parameters II - 240 【 #24013+40(n-1) 】 SLn delay time Delay time Set the delay time. "n" represents the expansion slot No.(n=1 to 3) 0: (Fixed value)---Master station---Set to "0" (fixed).---Local/standby master station---Set to "0". 【 #24014+40(n-1) 】 S...
II Parameters CC-Link Parameters II - 241 【 #24018+40(n-1) 】 SLn RWr dev name Remote register (RWr) refresh device name Set the refresh device name of the remote register (RWr) to be automatically refreshed.(Example) W"n" represents the expansion slot No.(n=1 to 3)Set "0" when no set...
II Parameters CC-Link Parameters II - 242 【 #24023+40(n-1) 】 SLn SB dev No. Special relay (SB) refresh device No. Set the refresh device No. of the special relay (SB) to be automatically refreshed. "n" represents the expansion slot No.(n=1 to 3) (Note 1) When setting parameters in ALL.PRM wi...
II Parameters CC-Link Parameters II - 243 【 #24121+15(m-1) 】 CNm station type Station type Set the type of the connected remote station, local station, intelligent device station and standby master station. 0: No setting1: Ver.1 remote I/O station2: Ver.1 remote device station3: Ver.1 intelligent de...
II Parameters CC-Link Parameters II - 244 【 #24126+15(m-1) 】 CNm set rsvd sta Reserved station Set the reserved/error invalid station."m" means the m-th connected station in ascending order of station No. (m= 1 to 64) 0: No setting1: Reserved station2: Error invalid station (Note) Refer to &...
II Parameters PLC Axis Indexing Parameters II - 245 16. PLC Axis Indexing Parameters (Note) This parameter description is common for M700V/M70V/E70 Series. It is written on the assumption that all option functions are added.Confirm with the specifications issued by the machine tool builder before st...
II Parameters PLC Axis Indexing Parameters II - 250 【 #12885 】 aux_PSW8dog1 PSW8 area setting 1 Set "PSW8 area setting" 1 and 2 to specify the area where the position switch 8 will turn ON when the machine is positioned. Whether the value of setting 1 is larger than setting 2 (or vice versa)...
II Parameters PLC Axis Indexing Parameters II - 251 【 #12894 】 aux_PSW12dog2 PSW12 area setting 2 Set "PSW12 area setting" 1 and 2 to specify the area where the position switch 12 will turn ON when the machine is positioned. Whether the value of setting 1 is larger than setting 2 (or vice ve...
II Parameters PLC Axis Indexing Parameters II - 252 【 #12913 】 aux_pusht3 Set position signal output delay time Set the time from the completion of the stopper operation to the output of the “automatic set position reached” (JSTA), “set position reached” (JST) or “near set position” (NEAR) signal in...
III PLC Devices Each Application : Pallet Program Registration Device Abbrev. Signal name R2100 Pallet program search valid / invalid state R2101 Continuous start valid / invalid state R2102 Pallet registration specification R2103 Number of valid pallets R2110 Pallet 1 0° Machining program device No...
III PLC Devices Each Application : Tool Life Management Interface Device Abbrev. Signal name R10604 AUX data R10610 No.1 magazine Number of magazines designation R10611 No.2 magazine Number of magazines designation R10612 No.3 magazine Number of magazines designation R10613 No.4 magazine Number of m...
Revision History Date of re- vision Manual No. Revision details Oct. 2008 IB(NA)1500928-A First edition created. Jan. 2009 IB(NA)1500928-B Mistakes were corrected. Jul. 2010 IB(NA)1500928-C Corrections are made corresponding to S/W version G1. Nov. 2011 IB(NA)1500928-D Corrections are made correspon...
Mitsubishi Manuals
-
Mitsubishi PKA-A18GA
User Manual
-
Mitsubishi PKA-A18GA
Installation Manual
-
Mitsubishi PKA-A18GAL
User Manual
-
Mitsubishi PKA-A18GAL
Installation Manual
-
Mitsubishi PCA-A42GA1
User Manual
-
Mitsubishi PCA-A42GA1
Installation Manual
-
Mitsubishi MSZ-FH18NA
User Manual
-
Mitsubishi MSZ-FH18NA
Installation Manual
-
Mitsubishi MSZ-D36NA
User Manual
-
Mitsubishi MSZ-D36NA
Installation Manual
-
Mitsubishi WD-82742
User Manual
-
Mitsubishi MSZ-FE09NA
User Manual
-
Mitsubishi MSZ-FE09NA
Installation Manual
-
Mitsubishi LT-46164
User Manual
-
Mitsubishi MSY-D36NA-8
User Manual
-
Mitsubishi MSY-D36NA-8
Installation Manual
-
Mitsubishi MSY-A15NA-1
User Manual
-
Mitsubishi MSY-A15NA-1
Installation Manual
-
Mitsubishi WD-73638
User Manual
-
Mitsubishi PKA-A36FA
User Manual