Page 2 - DATA G8; INDOOR UNITS; PKFY; Model
1. SPECIFICATIONS DATA G8 INDOOR UNITS 1 - 150 PKFY I.Wall mounted 1. SPECIFICATIONS Model PKFY-P15VBM-E PKFY-P20VBM-E PKFY-P25VBM-E PKFY-P32VHM-E Power source 1-phase 220-240V 50Hz, 1- phase 220V 60Hz 1-phase 220-240V 50Hz, 1- phase 220V 60Hz 1-phase 220-240V 50Hz, 1- phase 220V 60Hz 1-phase 220-24...
Page 3 - PK
1 - 151 1. SPECIFICATIONS DATA G8 INDOOR UNITS PK FY Model PKFY-P40VHM-E PKFY-P50VHM-E PKFY-P63VKM-E PKFY-P100VKM-E Power source 1-phase 220-240V 50Hz, 1- phase 220V 60Hz 1-phase 220-240V 50Hz, 1- phase 220V 60Hz 1-phase 220-240V 50Hz, 1- phase 220V 60Hz 1-phase 220-240V 50Hz, 1- phase 220V 60Hz Coo...
Page 4 - Terminal block Detailed; Detail of installation plate; Air intake; Installation space; Drain pipe
2. EXTERNAL DIMENSIONS DATA G8 INDOOR UNITS 1 - 152 PKFY 2. EXTERNAL DIMENSIONS M1 M2 N L 60mm or more for left and left back piping. Terminal block Air intake (Direction) Terminal block Detailed Address board The first side The second side Transmission (DC 24-30V) MA-remote controller (DC8.7-13V) T...
Page 5 - 50mm or greater with optional
1 - 153 2. EXTERNAL DIMENSIONS DATA G8 INDOOR UNITS PK FY Min.7 250mm or greater with optional drain pump installation. Required space (Indoor unit) Min.50 Min.220 Min.150 550mm or greater with optional drain pump installation. Min.250 Min.50 55mm or greater with left or rear left pipng or drain pum...
Page 8 - Main power supply; Legend; BZ
4. ELECTRICAL WIRING DIAGRAMS DATA G8 INDOOR UNITS 1 - 156 PKFY 4. ELECTRICAL WIRING DIAGRAMS PKFY-P15, 20, 25VBM-E Mark Meaning LED1 Main power supply Main power supply (indoor unit:220-240V)power on lamp is lit Function LED on indoor board for service ON OFF 1 2 3 4 MODELS SW2 P20 ON OFF 1 2 3 4 M...
Page 9 - Models; Mark; LED on indoor board for service
1 - 157 4. ELECTRICAL WIRING DIAGRAMS DATA G8 INDOOR UNITS PK FY PKFY-P32, 40, 50VHM-E <fig: 1> Models SW2 P32 P40 P50 1 2 3 4 5 6 ON OFF FAN CNMF (WHT) 1 6 3 MS 3~ M 1~ M VANE CN151 (WHT) 5 1 LEV CN60 (YLW) 6 6 1 CNRU (WHT) LDSWE(A) (BLU) 6 1 3 3 1 5 1 5 1 4 1 4 1 2 1 2 1 3 1 4 1 8 1 1 3 5 1 ...
Page 11 - Wall mounted
1 - 159 5. SOUND LEVELS DATA G8 INDOOR UNITS PK FY 5. SOUND LEVELS 5-1. Sound levels 5-2. NC curves * Measured in anechoic room. PKFY-P15VBM-E Sound level at anechoic room : Low-(Middle2-Middle)-High 29-31-32-33 Sound level dB (A) Model Wall mounted 1m Measurementlocation 1m PKFY-P20VBM-EPKFY-P25VBM...
Page 14 - -1. Optional parts line up for the Indoor unit; External LEV Box
7. OPTIONAL PARTS DATA G8 INDOOR UNITS 1 - 162 PKFY 7. OPTIONAL PARTS 7-1. Optional parts line up for the Indoor unit External LEV Box PAC-SG95LE-E PKFY-P15, 20, 25VBM-E PKFY-P32, 40, 50VHM-E PKFY-P63, 100VKM-E Drain pump PAC-SH75DM-E ā ā PAC-SH94DM-E 7-2. External LEV Box Cable(100mm) Cable(5300mm)...