Page 2 - GeneraL inForMation; Table 1; taBLe oF contents; dependable and enjoyable service from your LENNOX product.; introduction
2 The Electronic appliances have an electronic intermittent pilot system provides safe, efficient operation. External electrical power is required to operate these appliances. These appliances comply with National Safety Standards and are tested and listed by Omni- Test Laboratories (Report No. 116-...
Page 3 - Table 7; Cleaning Glass; must be disconnected; greater; by closing their; less than; Tables 4, 5 and 6 show the appliances' gas; Table 5; Gas controls/control compartment; openinG controL; operation and care oF Your; Figure 1; control Valve; Lower control
3 note: diaGraMs & iLLustrations are not to scaLe. Burner orifice sizes elevation 0-4500 feet ( 0-1372 meters) Model series natural Gas drill size (inches) propane Gas drill size (inches) LMdVt-3328 LMdVr-3328 #45 (.082") * 39L66 • 1.2 mm (.048") * 99K78 • LMdV-3530 #44 (.086") * 60J...
Page 4 - Variable Flame Height adjustment; Honeywell Millivolt Gas Valve; SIT Millivolt Gas Valve; Honeywell Electronic Gas Valve
4 note: diaGraMs & iLLustrations are not to scaLe. Figure 2 sit and Honeywell Millivolt Gas Valve showing piezo igniter Location (each unit is equipped with only one of these Gas Valves) Millivolt appliances - Appliances with Millivolt systems will be fitted with the gas control valve shown in F...
Page 5 - Maintenance; iMportant; 1 and as described in
5 note: diaGraMs & iLLustrations are not to scaLe. 3. Keep the lower control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, pet hair, etc. it is very important that the control comp...
Page 6 - Front Glass enclosure panel, removal; WarninG; eXercise eXtreMe caution; Figure 6; Figure 6; installing Glass enclosure panels
6 note: diaGraMs & iLLustrations are not to scaLe. WarninG Handle this glass with extreme care! tempered glass is suscep- tible to damage – do not scratch or handle roughly while rein- stalling the glass door frame. Front Glass enclosure panel, removal and installation WarninG do not operate app...
Page 7 - reFerence; Table 8; Glowing Embers; Bag of Glowing; instaLL VerMicuLite, VoLcanic; Remove the front glass enclosure panel; Handle logs carefully to prevent; Figure 7
7 note: diaGraMs & iLLustrations are not to scaLe. WarninG the size and position of the log set was engineered to give the appliance a safe, reliable and attractive flame pattern. any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combust...
Page 8 - Figure 8; Log placement instructions; DO NOT PLACE EMBERS OVER GAS SLOTS; LoG set; shown here (1 through 6) and per the instructions on
8 note: diaGraMs & iLLustrations are not to scaLe. Figure 8 ModeL LMdV-3328 & LMdV-3530 Log placement instructions d c e a B a e B c d Vermiculite Volcanic Stone Embers DO NOT PLACE EMBERS OVER GAS SLOTS 1 2 3 4 5 6 The 2 notches on log bottom rest on locating brackets Notch Notch Slot fits ...
Page 9 - Figure 9; install the embers, Vermiculite, Volcanic stone and Logs in
9 note: diaGraMs & iLLustrations are not to scaLe. Figure 9 ModeL LMdV-4035 Log placement instructions d c e a B 1 2 3 4 5 6 Vermiculite Volcanic Stone DO NOT PLACE EMBERS OVER GAS SLOTS Embers c a B e d Place log over pins Pin Pin Notch Notch The 2 notches on log bottom rest on locating bracket...
Page 10 - ensure front glass panel is in place; caution; Burner air shutter adjustment procedure; 2 (adjustment rod is located in the lower
10 note: diaGraMs & iLLustrations are not to scaLe. note: diaGraMs & iLLustrations are not to scaLe. Burner adJustMents (QuaLiFied tecHnicians onLY) Flame appearance and sooting Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange in the body of the flame...
Page 11 - carbon will be produced if the air; Burner air shutter adjustment; Pages 20 & 21. Ensure the igniter; WarrantY
11 note: diaGraMs & iLLustrations are not to scaLe. Main Burner Factory air shutter opening setting - inches (millimeter) Model natural Gas propane Gas LMdVt-3328 1/16" (1.58 mm) 1/4" (6.35 mm) LMdVr-3328 1/16" (1.58 mm) 1/4" (6.35 mm) LMdV-3530 1/16" (1.58 mm) 5/16" (7.9...
Page 12 - WirinG diaGraMs; Wiring diagrams are provided here for refer-; TP; thermopile; if any of the original wire as supplied must; Millivolt Wiring diagram; standard oFF/on switch; Label all wires prior to discon-; schematic representation only
12 note: diaGraMs & iLLustrations are not to scaLe. WirinG diaGraMs Wiring diagrams are provided here for refer- ence purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment. TH TP TH TP thermopil...
Page 13 - Model
13 note: diaGraMs & iLLustrations are not to scaLe. accessorY coMponents remote control Kit, standard cat. no. Model no. description H0249 rcL remote control system (standard) (ref. Form # 750,127M) remote control Kit, deluxe cat. no. Model no. description H0251 rcL-stat remote control system (d...
Page 14 - Arch Design; accessorY coMponents; decorative arch screen panel Kit
14 note: diaGraMs & iLLustrations are not to scaLe. style View screen doors - These Style View screen doors come in 4 beautiful styles. The Style View door installs over the standard glass enclosure panel and provides a barrier to prevent direct contact with the hot glass surface. The door inclu...
Page 15 - Forced air Kit; Brickaded panel Liner Kit; oFF/on Wall switch Kit
15 note: diaGraMs & iLLustrations are not to scaLe. 3 piece trim Kit cat. no. Model no. description H0453 tK33pB3 33” polished Brass, LMdVt-3328, LMdVr-3328 96K21 tK35pB3 35” polished Brass, LMdV-3530 96K22 tK40pB3 40" polished Brass, LMdV-4035 H1813 tK33Bs3 33” Brushed stainless, LMdVt-3328...
Page 16 - polished Brass & Brushed stainless 2-piece door Frame Kits; - piece door Frame Kits; polished Brass & Brushed stainless Louvers Kits; eyebrow Hood Kits; door Frame Kits; piece door trim Kits; termination Guard Kits
16 note: diaGraMs & iLLustrations are not to scaLe. accessorY coMponents * assembled 8-piece Louver Kits polished Brass Brushed stainless Models Where used cat. # Model cat. # Model H1522 LK-400B H1523 LK-400Bs LMdVt-3328 LMdVr-3328 H1524 LK-500B H1525 LK-500Bs LMdV-3530 H1526 LK-600B H1527 LK-6...
Page 17 - Sunrise Style; decorative Grille Kits; face of the appliance in place of the standard louvers.; tall style View doors -
17 note: diaGraMs & iLLustrations are not to scaLe. H3541 cuGK35c 35” charcoal upper GriLLe Kits crescents H3543 cuGK35sp 35” satin pewter H3549 cuGK40c 40” charcoal H3551 cuGK40sp 40” satin pewter H3569 sLGK35c 35” charcoal LoWer GriLLe Kits sunrise H3571 sLGK35sp 35” satin pewter H3577 sLGK40c...
Page 18 - LiGHtinG instructions – HoneYWeLL and sit MiLLiVoLt Gas VaLVe; For Your saFetY read BeFore LiGHtinG; Knob cannot be turned from “PILOT” to “OFF”; sit
18 LiGHtinG instructions – HoneYWeLL and sit MiLLiVoLt Gas VaLVe For Your saFetY read BeFore LiGHtinG a. This appliance has a pilot which must be lighted with a piezo igniter. When lighting the pilot, follow these instructions exactly. B. BeFore operatinG smell all around the appliance area for gas....
Page 19 - INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT; INSTRUCTIONS D'ALLUMAGE; VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE ODEUR; POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL; VANNE GAZ; HONEYWELL
19 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT INSTRUCTIONS D'ALLUMAGE 8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé. Allumez immédiatement la veilleuse en déclenchant l’allume-gaz à étincelle (en poussant le b...
Page 20 - LiGHtinG instructions — eLectronic; to turn oFF Gas to appLiance; Honeywell electronic Gas control Valve
20 WarninG: iF You do not FoLLoW tHese instructions eXactLY, a Fire or eXpLosion MaY resuLt causinG propertY daMaGe, personaL inJurY or Loss oF LiFe. a. When lighting the appliance, follow these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell n...
Page 21 - INSTRUCTIONS D’ALLUMAGE — ELECTRONIC; INSTRUCTIONS D’ALLUMAGE; VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE; Interrupteur; Vue de face
21 note: diaGraMs & iLLustrations are not to scaLe. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE — ELECTRONIC INSTRUCTIONS D’ALLUMAGE POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE A. Lorsque vous allumez l’appareil, suivez exactement ces instruc- tions....
Page 22 - periodically
22 Maintenance tasK accoMpLisHinG person procedure Inspecting/Cleaning Burner, Logs and Controls Qualified Service Technician Inspect valve and ensure it is properly operating. Check piping for leaks. Vacuum the control compartment, fireplace logs and burner area. Check Flame Patterns and Flame Heig...
Page 24 - trouBLesHootinG procedure - eLectronic iGnition sYsteM
24 note: diaGraMs & iLLustrations are not to scaLe. start cHecK • turn off Gas supply.• ensure Valve switch is in on position.• disconnect control Harness.• set thermostat to call For Heat. • check for proper volt- age at control harness (see insert a). Voltage should be 24V between thermostat o...
Page 27 - repLaceMent parts
27 note: diaGraMs & iLLustrations are not to scaLe. note: tHis paGe intentionaLLY LeFt BLanK. note: diaGraMs & iLLustrations are not to scaLe. repLaceMent parts PA I N T 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20 31 21 8 LMdV-4035 LMdVt-3328 & LMdVr-...