Milwaukee 2282-20 2 EN Genaral Safety Instructions WARNING Read all safety warnings and instructions.Before using the appliance, read these safety instructions, the appliance’s oper-ator’s manual (found on the enclosed CD) and all labels on the appliance. • Do not allow persons unfamiliar with the...
Page 3 - Introduction; The symbols used have the following meanings:; Overview; Display
Milwaukee 2282-20 3 EN Instrument Set-up Introduction The safety instructions and the user manual should be read through carefully before the product is used for the first time. The person responsible for the product must ensure that all users understand these directions and adhere to them. The symb...
Page 5 - Labeling
Milwaukee 2282-20 Instrument Set-up 5 EN Labeling Laser Radiation Do not stare into the beam Laser class 2 acc. IEC 60825-1:2007 Maximum radiant power: <1mW Emitted wavelength: 620-690nm Beam divergence: 0.16 x 0.6 mrad Impulse duration: 0.2 x 10 -9 s - 0.8 x 10 -9 s Subject to change (drawings, ...
Page 6 - Operations; Clear; ously
Milwaukee 2282-20 6 EN Operations Switching ON/OFF Clear Message Codes 2 sec Device is turned OFF. i Press ON but-ton 2 sec to start continuous laser mode. If no key is pressed for 180 sec, the device switches off au-tomatically. 1x Undo last action. 2x Leave actual function, go to de-fault operatio...
Page 7 - Adjusting measuring reference / tripod
Milwaukee 2282-20 Operations 7 EN Adjusting measuring reference / tripod Distance is measured from the front of the device. 1 Distance is measured from the tripod thread permanently. 2 Distance is measured from the rear of the device (standard setting). 3 Multifunctional endpiece i The orientation o...
Page 8 - Distance unit setting; simultaneously
Milwaukee 2282-20 Operations 8 EN Distance unit setting Tilt unit setting 0.000 m0.0000 m0.00 m 0.00 ft0‘00‘‘ 1/320.00 in0 in 1/32 Switch between the following units: 2 sec 0.0 °0.0 % 2 sec simultaneously Switch between the following units: Timer (automatic release) s 1 Adjust delay of au-tomatic re...
Page 9 - Measuring Functions; Measuring single distance; Aim active laser at target.
Milwaukee 2282-20 9 EN Measuring Functions Measuring single distance 1 Aim active laser at target. 2 8.532 m 3 i Target surfaces: Measuring errors can occur when meas-uring to colourless liquids, glass, styrofoam or semi-per-meable surfaces or when aiming at high gloss surfac-es. Against dark surfac...
Page 10 - Area; Circumference
Milwaukee 2282-20 Measuring Functions 10 EN Area 1 1x 2 Aim laser at first target point. 3 4 Aim laser at sec-ond target point. 24.352 m 2 5 i The result is shown in the main line and the measured value above. 19.823 m 24.352 m 2 2 sec Circumference Area 6
Page 11 - Volume
Milwaukee 2282-20 Measuring Functions 11 EN Volume 1 2x 2 Aim laser at first target point. 3 4 Aim laser at sec-ond target point. 5 6 Aim laser at third target point. 78.694 m 3 7 i The result is shown in the main line and the measured value above. 208.703 m 2 80.208 m 78.694 m 3 24.224 m 2 208.703 ...
Page 12 - Aim laser at lower point.
Milwaukee 2282-20 Measuring Functions 12 EN Pythagoras (2-point) 1 2 Aim laser at up-per point. 3 4 Aim laser rectan-gular at lower point. 8.294 m 5 i Notice additional Pythagoras measurement in-formation at the bottom of the next page. Pythagoras (3-point) 1 2x 2 Aim laser at up-per point. 3 4 Aim ...
Page 14 - Stake out
Milwaukee 2282-20 Measuring Functions 14 EN Stake out i Two different distances (a and b) can be entered to mark off de-fined meas-ured lengths. 1 2 3 a = b a b b 1 2 3 a b b a = b 1.000 m 1 4x 1.012 m Adjust value "a". 2 3 Approve value "a". 0.625 m 4 Adjust value "b". 5 App...
Page 15 - Smart Horizontal Mode; height
Milwaukee 2282-20 Measuring Functions 15 EN Smart Horizontal Mode 1 Aim laser at target. 2 z x y 0.032 m 5.204 m 40.8 ° 4.827 m xy z 3 (up to 360° and a transverse tilt of ±10°) i Press key again to switch off horizontal measure-ment. Height tracking i This function displays continous-ly the trackin...
Page 16 - Delete Memory
Milwaukee 2282-20 Measuring Functions 16 EN Memory (20 last displays) Delete Memory 8.294 m 20 20 last displays are displayed. 1 8.294 m 20 Navigates trough 20 last displays. 2 The value from the main line can be used for fur-ther calculations. 2 sec 3 2 sec simultaneously Memory is completely de-le...
Page 17 - Calibration; Calibration of tilt sensor (Tilt Calibration)
Milwaukee 2282-20 17 EN Calibration Calibration of tilt sensor (Tilt Calibration) 1 2 sec simultane- ously 2 Place device on absolutely flat sur-face. 3 180° 4 Turn the device horizontally by 180° and place it again on absolutely flat surface. 5 6 Turn the device and place it again on ab-solutely fl...
Page 18 - If the message; Error; does not disappear; InFo; appears with a
Milwaukee 2282-20 18 EN Technical Data * applies for 100 % target reflectivity (white painted wall), low background illumination, 25 ºC** applies for 10 to 500 % target reflectivity, high back-ground illumination, - 10 ºC to + 50 ºC*** Tolerances apply from 0.05 m to 10 m with a confi-dence level of...