Page 2 - Genaral Safety Instructions; WARNING
Milwaukee 2281-20 2 EN Genaral Safety Instructions WARNING Read all safety warnings and instructions.Before using the appliance, read these safety instructions, the appliance’s oper-ator’s manual (found on the enclosed CD) and all labels on the appliance. • Do not allow persons unfamiliar with the...
Page 3 - Introduction; Overview
Milwaukee 2281-20 3 EN Instrument Set-up Introduction The safety instructions and the user manual should be read through carefully before the product is used for the first time. The person responsible for the product must ensure that all users understand these directions and adhere to them. The symb...
Page 5 - Labeling
Milwaukee 2281-20 Instrument Set-up 5 EN Labeling Laser Radiation Do not stare into the beam Laser class 2 acc. IEC 60825-1:2007 Maximum radiant power: <1mW Emitted wavelength: 620-690nm Beam divergence: 0.16 x 0.6 mrad Impulse duration: 0.2 x 10 -9 s - 0.8 x 10 -9 s Subject to change (drawings, ...
Page 6 - Operations; Clear; simultaneously; Distance unit setting
Milwaukee 2281-20 6 EN Operations Switching ON/OFF Clear Message Codes 2 sec Device is turned OFF. i Press ON but-ton 2 sec to start continuous laser mode. If no key is pressed for 180 sec, the device switches off au-tomatically. 1x Undo last action. 2x Leave actual function, go to de-fault operatio...
Page 7 - Adjusting measuring reference / tripod
Milwaukee 2281-20 Operations 7 EN Adjusting measuring reference / tripod Distance is measured from the front of the device. 1 Distance is measured from the tripod thread permanently. 2 Distance is measured from the rear of the device (standard setting). 3 Multifunctional endpiece i The orientation o...
Page 8 - Measuring Functions; Measuring single distance; Aim active laser at target.
Milwaukee 2281-20 8 EN Measuring Functions Measuring single distance 1 Aim active laser at target. 2 8.532 m 3 i Target surfaces: Measuring errors can occur when meas-uring to colourless liquids, glass, styrofoam or semi-per-meable surfaces or when aiming at high gloss surfac-es. Against dark surfac...
Page 9 - Area; Circumference
Milwaukee 2281-20 Measuring Functions 9 EN Area 1 1x 2 Aim laser at first target point. 3 4 Aim laser at sec-ond target point. 24.352 m 2 5 i The result is shown in the main line and the measured value above. 19.823 m 24.352 m 2 2 sec Circumference Area 6
Page 10 - Volume
Milwaukee 2281-20 Measuring Functions 10 EN Volume 1 2 Aim laser at first target point. 3 4 Aim laser at sec-ond target point. 5 6 Aim laser at third target point. 78.694 m 3 7 i The result is shown in the main line and the measured value above. 208.703 m 2 80.208 m 78.694 m 3 208.703 m 2 80.208 m 7...
Page 11 - Aim laser at lower point.
Milwaukee 2281-20 Measuring Functions 11 EN Pythagoras (2-point) 1 2 Aim laser at up-per point. 3 4 Aim laser rectan-gular at lower point. 8.294 m 5 i Notice additional Pythagoras meas-urement informa-tion at the bottom of the next page. Pythagoras (3-point) 1 2x 2 Aim laser at up-per point. 3 4 Aim...
Page 12 - Stake out; Adjust value
Milwaukee 2281-20 Measuring Functions 12 EN Stake out 1 2 3 a b b 1.000 m 1 3x 1.012 m Adjust value 2 3 Approve value and start measurement. 4 Move device slow-ly along the stake-out line. The dis-tance to the next stake out point is displayed. 0.625 m 0.240 m 0.240 m is missing up to next 0.625 m d...
Page 13 - Delete Memory
Milwaukee 2281-20 Measuring Functions 13 EN Memory (10 last displays) Delete Memory 8.294 m 10 10 last displays are displayed. 1 8.294 m 10 Navigates trough 10 last displays. 2 The value from the main line can be used for fur-ther calculations. 2 sec 3 2 sec simultaneously Memory is completely de-le...
Page 14 - If the message; Error; does not disappear; InFo; appears with a; Care; Clean the device with a damp, soft cloth.
Milwaukee 2281-20 14 EN Technical Data * applies for 100 % target reflectivity (white painted wall), low background illumination, 25 ºC** applies for 10 to 500 % target reflectivity, high back-ground illumination, - 10 ºC to + 50 ºC*** Tolerances apply from 0.05 m to 10 m with a confi-dence level of...
Page 15 - Service - United States
Milwaukee 2281-20 15 EN Service - United States MILWAUKEE prides itself in producing a premium quality product that is Nothing But Heavy Duty ® . Your satisfaction with our products is very important to us!If you encounter any problems with the operation of this tool, or you would like to locate the...