Page 2 - declares that the product:; All; conforms to the following Product Specifications:; ULL; Declaration of Conformity; Environmental Specifications for; Symbols Used
2 According to ISO/IEC Guide and EN 45014 The product herewith complies with the require-ments of the Low Voltage Directive 73/23/EEC andthe EMC Directive 89/336/EEC. declares that the product: The Manufacturer: Product Name : PSM-2 Product Options : All Name : Meyer Sound Laboratories Address : 283...
Page 3 - Contents; European User Panel with; Dimensions; Front; All units in inches
3 A T E N C I Ó N : A C C E S O I N T E R A U T O R I Z A D O A P E R S O N A L T É A C H T U N G : G E H Ä U S E N I C H T U N D R E P A R A T U R N U R D U R C H A T T E N T I O N : E N T R E T I E N E T I N T E R N E S N E S O N T A U T O R I U P E R S O N N E L T E C H N I Q U E Q U A U K W A R ...
Page 4 - AC Power; Continuous voltages above 275 VAC may; Power Requirements; Vpk; = Ipk x Total Cable Resistance
4 AC Power The AC voltage operating ranges for the PSM-2 are85–134 V and 165–264 V, at 50 or 60 Hz. The PSM-2performs surge suppression for high voltage transientsand can safely withstand voltages up to 275 VAC. Continuous voltages above 275 VAC may damage the unit! When an AC source is applied to t...
Page 5 - Differential Inputs; Audio Input; The PSM-2 presents a 10 k; to chassis and earth ground (ESD clamped); Case; Shorting an input connector pin to the case can; source is used, the 500; Troubleshooting
5 Differential Inputs Audio Input The PSM-2 presents a 10 k Ω input impedance to a three- pin XLR connector wired with the following convention: Pin 1 — 220 k Ω to chassis and earth ground (ESD clamped) Pin 2 — Signal Pin 3 — Signal Case — Earth (AC) ground and chassis Pins 2 and 3 carry the input a...
Page 6 - Hi Limit; Troubleshooting with TPL
6 Limiting and ProtectionCircuitry TruPower Limiting System Conventional limiters assume that the resistance of aspeaker remains constant and set the limiting thresholdby measuring voltage only. This method is inaccuratebecause the speaker’s resistance changes in responseto the frequency content of ...
Page 7 - Example Applications
7 The fans draw air in through ducts on the front of thecabinet, over the heatsinks, and out the rear of thecabinet. Since dust does not accumulate in the amplifiercircuitry, its life span is increased significantly. Makesure that the air ducts are clear and that there is atleast 6” clearance for ex...
Page 8 - loop; connection on the user; Verifying Polarity; Polarity Between Adjacent PSM-2s; Top view of adjacent PSM-2s; Driver Polarity in the Same PSM-2
8 PSM-2 and PSW-2 The PSM-2 can be used with the Meyer PSW-2, PSW-4,or 650-P self-powered subwoofers. However, due to theoverlap of frequency response between the PSM-2 andthe subwoofer, the system frequency response exhibits arise in the range 50–120 Hz. The rise can be eliminatedby the Meyer CP-10...
Page 9 - Safety Summary
9 • To reduce the risk of electric shock, disconnect the loudspeaker from the AC mains before installing audiocable. Reconnect the power cord only after making allsignal connections. • Connect the loudspeaker to a two-pole, three wire grounding mains receptacle. The receptacle must beconnected to a ...
Page 10 - Specifications; Notes
10 Complementary power MOSFET output stages class AB/H 1240 Watts (620 Watts per channel) < .02 % Acoustical Copyright © 1997, Meyer Sound Laboratories, Inc. All rights reserved Part #: 05.044.012.01 Rev A ± 4 dB 50 Hz – 18 kHz ± 90 ° 200 Hz – 16 kHz 139 dB peak at 1 m > 110 dB –6 dB: 50 ° H x...