Page 2 - EC DECLARATION OF CONFORMITY
ii EC DECLARATION OF CONFORMITY within the meaning of the EC Machine Directive 2006/42/EC © 2012 Meyer Sound. All rights reserved.MTG-1100 Assembly Guide, PN 05.220.030.01 A The contents of this manual are furnished for informational purposes only, are subject to change without notice, and should ...
Page 3 - CONTENTS; Chapter 1: Introduction
iii CONTENTS Chapter 1: Introduction 5 How to Use This Manual 5 Safety, Regulatory, Inspection & Maintenance Information 5 Chapter 2: 1100-LFC Groundstacks and Cardioid Arrays 9 Groundstacking 1100-LFC Loudspeakers 9 1100-LFC Cardioid Arrays 10 Chapter 3: MRK-1100 Rigging Kit 11 MRK-1100 Rigging...
Page 5 - CHAPTER 1: INTRODUCTION; HOW TO USE THIS MANUAL; A tip offers a helpful tip relevant to the topic at hand.; Scope of this Manual; system are knowledgeable and experienced; Load Ratings and Specifications
5 CHAPTER 1: INTRODUCTION HOW TO USE THIS MANUAL Make sure to read these operating instructions in their entirety before configuring a loudspeaker system with 1100-LFC loudspeakers. In particular, pay close attention to material related to safety issues. As you read these operating instructions, you...
Page 6 - Regulatory Compliance
CHAPTER 1: INTRODUCTION 6 All load ratings and other specifications given in this manual are the result of accepted engineering practice and careful test-ing. However, such specifications and ratings are subject to change. USERS SHOULD CHECK THE QUICKFLY SECTION OF THE MEYER SOUND WEBSITE AT www.mey...
Page 7 - Annual Comprehensive Examination and Test Program; Replacement Parts; Always use properly rated rigging hardware.
MG-MINA GRID ASSEMBLY GUIDE 7 Annual Comprehensive Examination and Test Program In addition to routine checks on the road for touring systems, Meyer Sound also recommends a careful, comprehensive sys-tem examination and testing “at home” in the warehouse or other appropriate location at regular inte...
Page 9 - CHAPTER 2: 1100-LFC GROUNDSTACKS AND CARDIOID ARRAYS; GROUNDSTACKING 1100-LFC LOUDSPEAKERS
9 CHAPTER 2: 1100-LFC GROUNDSTACKS AND CARDIOID ARRAYS GROUNDSTACKING 1100-LFC LOUDSPEAKERS 1100-LFCs can be groundstacked up to four units high, with or without the MRK-1100 rigging kit. Protective, plastic skids are included on the bottom of the 1100-LFC cabinet that securely align with the slots ...
Page 10 - loudspeaker management
CHAPTER 2: 1100-LFC GROUNDSTACKS AND CARDIOID ARRAYS 10 1100-LFC CARDIOID ARRAYS The 1100-LFC low-frequency control element is defined by its sonic linearity in reproducing low-frequency transients at high, continuous output levels with very low distortion. This ultra low distortion, coupled with ex...
Page 11 - MRK-1100 RIGGING KIT CONTENTS; The MRK-1100 rigging kit includes the following components:
11 CHAPTER 3: MRK-1100 RIGGING KIT The optional MRK-1100 rigging kit allows the 1100-LFC to be flown from the MTG-1100 top grid. The rigging kit is available as a factory-installed option or as a field upgrade and uses rugged GuideALinks and intuitive quick-release pins to securely link adjacent lou...
Page 12 - INSTALLING THE MRK-1100 RIGGING KIT
CHAPTER 3: MRK-1100 RIGGING KIT 12 INSTALLING THE MRK-1100 RIGGING KIT To install the MRK-1100 rigging kit: 1. Use a 7/32-inch hex wrench to remove the 16 3/8-inch flathead socket bolts from the 1100-LFC (8 on each side of the cab- inet). 2. Apply 1 or 2 drops of Loctite to each 3/8-inch flathead so...
Page 16 - MTG-1100 Top Grid Kit Contents
CHAPTER 4: MTG-1100 TOP GRID 16 TIP: The MTG-1100 top grid can travel installed on top of 1100-LFC stacks. TIP: The MTG-1100 top grid includes 0.28-inch, center attachment points that accommodate brackets and adapters for lasers and inclinometers. MTG-1100 Top Grid Kit Contents MTG-1100 Top Grid Dim...
Page 17 - MTG-1100 TOP GRID LOAD RATINGS; points should not be used to tilt the array.; Requirements for MTG-1100 Top Grid Load Ratings; There should be no splay between loudspeakers.
MG-MINA GRID ASSEMBLY GUIDE 17 MTG-1100 TOP GRID LOAD RATINGS The following table lists the maximum suspended weight for the MTG-1100 top grid. NOTE: The grid tilt should not be larger than the one achieved by the natural rotation of the array. Pull-back points should not be used to tilt the array. ...
Page 19 - CHAPTER 5: MTG-1100 PICKUP CONFIGURATIONS; TWO PICKUP POINTS
19 CHAPTER 5: MTG-1100 PICKUP CONFIGURATIONS The MTG-1100 top grid accommodates a variety of pickup configurations with its six pickup points, three each on the front and rear of the grid. When possible, use the front and rear pickup points to change the tilt of the grid with the front and rear moto...
Page 20 - THREE PICKUP POINTS
CHAPTER 5: MTG-1100 PICKUP CONFIGURATIONS 20 THREE PICKUP POINTS The MTG-1100 top grid supports the following configurations with three pickup points. CAUTION: When suspending MTG-1100 arrays from one or two motors, make sure each motor and ceiling pickup point (above the hook) are rated to hold the...
Page 21 - FOUR PICKUP POINTS
MG-MINA GRID ASSEMBLY GUIDE 21 FOUR PICKUP POINTS The MTG-1100 top grid supports the following configurations with four pickup points. CAUTION: When suspending MTG-1100 arrays from one or two motors, make sure each motor and ceiling pickup point (above the hook) are rated to hold the total weight of...
Page 23 - center attachment points.
23 CHAPTER 6: MVP-LEO-M VEE PLATE The optional MVP-LEO-M Vee plate provides ±21 degrees of horizontal rotation for the MTG-1100 top grid. The bottom of the Vee plate attaches to the grid’s rear center attachment point. The top corners of the Vee plate attach to two motors, which, when adjusted, affe...
Page 28 - The MTG-1100 top grid can travel installed on top of 1100-LFC stacks.
CHAPTER 8: MCF-1100 CASTER FRAME 28 1100-LFC cabinets equipped with the MRF-1100 rigging kit provide for more secure transport as the bottom cabinet can be linked and pinned to the caster frame (see Figure 2). Each of the three cabinets can be linked and pinned together as well. TIP: The MTG-1100 to...
Page 30 - SAFETY GUIDELINES FOR THE MCF-1100 CASTER FRAME; Do not stack more than three 1100-LFCs on the caster frame.
CHAPTER 8: MCF-1100 CASTER FRAME 30 SAFETY GUIDELINES FOR THE MCF-1100 CASTER FRAME ■ Do not stack more than three 1100-LFCs on the caster frame. ■ Use straps when transporting 1100-LFCs that have not been fitted with the MRK-1100 rigging kit. ■ Avoid moving stacks in the front-to-back direction of ...
Page 31 - APPENDIX A: ASSEMBLING ARRAYS WITH THE MTG-1100 TOP GRID; Link the suspended 1100-LFCs to the next stack in the array:
31 APPENDIX A: ASSEMBLING ARRAYS WITH THE MTG-1100 TOP GRID To assemble an 1100-LFC array with the MTG-1100 top grid: 1. Attach the MTG-1100 top grid to the motors: ■ Place the MTG-1100 on the floor or on a road trunk in the approximate location where the rigging points have been established and the...