Page 2 - INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE; IMPORTANT SAFETY INSTRUCTIONS; DO NOT MAKE ANY ATTEMPT TO
2 INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE IMPORTANT SAFETY INSTRUCTIONS • Be sure your range is installed and groundedproperly by a qualified installer or servicetechnician. • This range must be electrically grounded inaccordance with local codes or, in their absence,with the National Ele...
Page 3 - For gas supply connection:; Phillips head and; small
3 INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE Tools you will need (Wear safety glasses when using tools): For leveling legs and Anti-Tip Bracket: • Adjustable wrench or channel lock pliers (Fig. a) • 5/16" Nutdriver or flat head screwdriver (Fig. b) • Electric drill & 1/8" drill b...
Page 4 - Installation with cabinets
4 INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE Installation with cabinets Check location where the range willbe installed for proper electric andgas supply, and stability of the floor. The dimensions shown here mustbe used and are minimal unlessotherwise stated. Thesemeasurements do not allow ...
Page 5 - Install anti-tip bracket; Anti-tip bracket installation instructions; Locate the bracket using the template; - Level range by adjusting the
5 INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE Install anti-tip bracket IMPORTANT SAFETY WARNING! To reduce the risk of tipping of the range, the rangemust be secured to the floor by properly installed anti-tip bracket and screws packed with the range. Failureto install the anti-tip bracket wi...
Page 6 - Connect range to gas supply.; Note: To prevent leaks use pipe joint sealant on all male; Provide an adequate gas supply.; For proper operation; stabilize
6 INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE Connect range to gas supply. Note: To prevent leaks use pipe joint sealant on all male (outside) pipe threads. Do not allow gas pressureregulator to turn on pipe when tightening fittings. a. Install an external manual gas shut-off valve to gassupp...
Page 7 - Checking manifold gas pressure; Do not use flame to check for gas leaks.; of torque. Be sure to; Make sure the; service shut-off valve on pressure
7 INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE Checking manifold gas pressure Do not use flame to check for gas leaks. Disconnect the range and its individual shut-off valve fromthe gas supply piping system during any pressure testing ofthat system at test pressures greater than 14" of wat...
Page 8 - Electric requirements:; Check burner cap placement.
8 INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE Read the following electricalconnection details beforeconnecting electricity to range. Before servicing, disconnect electrical supply at circuit breaker, fuse or power cord. Electric requirements: A dedicated, properly grounded and polarized branc...
Page 9 - Check ignition of oven burners.; Note: Air mixture adjustments are not required on surface
9 INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE Check ignition of oven burners. The operation of oven igniters should be checked afterrange and supply line connectors have been carefullychecked for leaks and range has been connected toelectric power. Be sure all packing materials andliterature ...
Page 10 - Make sure range is level.; Note: After installation is complete, make sure all controls; Care, cleaning and maintenance; burner air shutter; Broil; . If the flame is yellow, increase upper oven
10 INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE Make sure range is level. Level the range by placing a level horizontally on an ovenrack. Check diagonally from front to back, then level therange by either adjusting the leveling legs or by placingshims under the corners of the range as needed. ...