Page 2 - DRYER SAFETY
2 DRYER SAFETY IMPORTANT: When discarding or storing your old clothes dryer, remove the door.
Page 4 - INSTALLATION REQUIREMENTS; If using a power supply cord:
4 TOOLS AND PARTS Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools needed for all installations: Level #2 Phillips screwdriver Wire stripper (direct wire installations) Parts supplied (all models): Flat-blad...
Page 5 - LOCATION REQUIREMENTS; DRYER DIMENSIONS
5 Parts needed: (Not supplied with dryer) Check local codes. Check existing electrical supply and venting. See “Electrical Requirements” and “Venting Requirements” before purchasing parts. Mobile home installations require metal exhaust system hardware available for purchase from the dealer from who...
Page 6 - ELECTRICAL REQUIREMENTS –
6 Mobile home – Additional installation requirements: This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 2...
Page 7 - ELECTRICAL REQUIREMENTS; GROUNDING INSTRUCTIONS; If your outlet looks like this:; If your outlet looks like this:
7 4-wire receptacle (14-30R) ELECTRIC DRYER POWER HOOKUP – CANADA ONLY ELECTRICAL REQUIREMENTS It is your responsibility: ■ To contact a qualified electrical installer. ■ To be sure that the electrical connection is adequate and in conformance with Canadian Electrical Code, C22.1 – latest edition an...
Page 8 - GAS DRYER POWER HOOKUP –
8 GAS TYPE Natural Gas: This dryer is equipped for use with Natural gas. It is design- certified by CSA International for LP (propane or butane) gases with appropriate conversion. ■ Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating ...
Page 9 - DRYER GAS PIPE; INSTALL LEVELING LEGS; Prepare dryer for leveling legs
9 3/8" NPT dryer pipe NOTE: For a garage installation, the gas pipe height must be an additional 18" (460 mm) from the floor. GAS SUPPLY CONNECTION REQUIREMENTS ■ Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as ne...
Page 10 - ELECTRICAL CONNECTION; POWER SUPPLY CORD CONNECTION
10 MAKE ELECTRICAL CONNECTION – U.S.A. ONLY (EFFECTUER LE RACCORDEMENT ÉLECTRIQUE – ÉTATS-UNIS SEULEMENT) ELECTRICAL CONNECTION Electrical Connection Options Power Supply Cord 1. Choose electrical connection type Power supply cord 4-wire receptacle (NEMA Type 14-30R): Go to “Power Supply Cord Connec...
Page 11 - -Wire Power Supply Cord Connection
11 4-Wire Power Supply Cord Connection IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections. Power supply cord 4-wire receptacle (NEMA Type 14-30R): Go to “4-Wire Power Supply Cord Connection”. Power supply cord 3-wire receptac...
Page 12 - -Wire Power Supply Cord Connection; Connect remaining wires; Direct Wire Strain Relief; DIRECT WIRE CONNECTION
12 3-wire receptacle (NEMA-type 10-30R) 3-prong plug Spade terminals with upturned ends Ring terminals Use where local codes permit connecting cabinet-ground conductor to neutral wire. 3-Wire Power Supply Cord Connection 3. Connect remaining wires Connect remaining wires to outer terminal block scre...
Page 13 - -Wire Direct Wire Connection
13 Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable. 2. Attach direct wire cable to strain relief 3-wire direct connection: Go to “3-Wire Direct...
Page 14 - -Wire Direct Wire Connection
14 Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to “Venting Requi...
Page 15 - Optional 3-Wire Connection
15 1. Prepare to connect neutral ground wire and neutral wire B A E Remove center terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A). Optional 3-Wire Connection You must verify with a qualified electrician that this grounding method is acceptable before...
Page 16 - VENTING; Connect gas supply to dryer; Plan pipe fitting connection; MAKE GAS CONNECTION –
16 VENTING REQUIREMENTS WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances. Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid ...
Page 18 - Special provisions for mobile homes:; CONNECT INLET HOSES; Connect vent to exhaust hood; INSTALL VENT SYSTEM; Install exhaust hood; Determine vent length and elbows needed for best; Turn cold water off, remove
18 Special provisions for mobile homes: Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home. Terminate exhaust vent outside. Mobile Home Exhaust installation CONNECT INLET HOSES For non-steam models, skip to “Connect Vent.”...
Page 20 - LEVEL DRYER; CONNECT VENT; Connect vent to exhaust outlet; Move dryer to final location
20 LEVEL DRYER Not Level LEVEL Not Level Check levelness of dryer from side to side. Repeat from front to back. NOTE: The dryer must be level for the moisture sensing system to operate correctly. CONNECT VENT 1. Connect vent to exhaust outlet Using a 4" (102 mm) clamp, connect vent to exhaust ou...
Page 22 - REVERSE DOOR SWING; Remove door from dryer cabinet
22 REVERSE DOOR SWING You can change your door swing from a right-hinge opening to a left-hinge opening, if desired. NOTE: To complete the door swing reversal exactly as seen in these instructions, a door reversal kit must be purchased. For ordering information, please reference the Use and Care Gui...
Page 25 - SÉCURITÉ DE LA SÉCHEUSE
25 SÉCURITÉ DE LA SÉCHEUSE IMPORTANT : Pour mettre l’ancienne sécheuse au rebut ou pour la remiser, enlever la porte.
Page 27 - EXIGENCES D’INSTALLATION; OUTILLAGE ET PIÈCES
27 Niveau Mètre-ruban Pince Pièces fournies (tous les modèles) : Tournevis à lame plate Clé à molette avec ouverture jusqu’à 1" (25 mm) ou clé à douille hexagonale Cisaille de ferblantier (pour l’installation d’un nouveau conduit) Pistolet à calfeutrage et composé de calfeutrage (pour l’installa...
Page 28 - Pièces nécessaires :; EXIGENCES D’EMPLACEMENT; DIMENSIONS DE LA SÉCHEUSE
28 Pièces nécessaires : (Non fourni avec la sécheuse) Consulter les codes locaux. Vérifier l’alimentation électrique et le circuit d’évacuation existants. Voir “Installations électriques” et “Exigences concernant l’évacuation” avant d’acheter les pièces. Les installations pour maison mobile nécessit...
Page 30 - RACCORDEMENT ÉLECTRIQUE; SPÉCIFICATIONS ÉLECTRIQUES
30 4-wire receptacle (14-30R) ■ Cette sécheuse est équipée d’un cordon électrique homologué par la CSA International à introduire dans une prise murale standard 14-30R. Le cordon mesure 5 pi (1,52 m). Veiller à ce que la prise murale se trouve à proximité de l’emplacement définitif de la sécheuse. P...
Page 31 - Conversion pour l’alimentation au propane :; SPÉCIFICATIONS DE L’ALIMENTATION EN GAZ
31 Conversion pour l’alimentation au propane : IMPORTANT : Un technicien qualifié doit effectuer la conversion. Ne pas entreprendre de convertir la sécheuse dans le cas d’une utilisation avec un gaz différent de celui indiqué sur la plaque signalétique sans d’abord consulter la compagnie de gaz. CAN...
Page 32 - Préparer la sécheuse pour
32 Conduit NPT de la sécheuse de 3/8" REMARQUE : Pour une installation dans un garage, prévoir 18" (460 mm) de plus à partir du sol pour la hauteur de la canalisation d’arrivée de gaz. Saisir fermement le corps de la sécheuse (et non pas le panneau de la console) puis reposer la sécheuse ave...
Page 33 - EXIGENCES CONCERNANT L’ÉVACUATION; L’ÉVACUATION; Conduit métallique rigide :; Raccorder l’alimentation; RACCORDEMENT AU GAZ –; Planifier la connexion
33 EXIGENCES CONCERNANT L’ÉVACUATION AVERTISSEMENT : Pour réduire le risque d’incendie, cette sécheuse doit EVACUER L’AIR A L’EXTERIEUR. IMPORTANT : Observer les dispositions de tous les codes et règlements en vigueur. Le conduit d’évacuation de la sécheuse ne doit pas être raccordé à une évacuation...
Page 35 - Installer le clapet d’évacuation; Tableau des systèmes d’évacuation
35 INSTALLATION DU SYSTÈME D’ÉVACUATION 12" min. (305 mm) 12" min. (305 mm) 1. Installer le clapet d’évacuation Installer le clapet d’évacuation et utiliser un composé de calfeutrage pour calfeutrer le côté extérieur de l’ouverture murale autour du clapet d’évacuation. Installations d’évacua...
Page 38 - ÉTABLIR L’APLOMB DE LA SÉCHEUSE; Réglage de l’aplomb de la sécheuse; Ajuster pieds de nivellement; ACHEVER L’INSTALLATION LISTE; Modèles électriques :
38 ÉTABLIR L’APLOMB DE LA SÉCHEUSE 1. Réglage de l’aplomb de la sécheuse Pas d’aplomb D’APLOMB Pas d’aplomb Vérifier l’aplomb de la sécheuse dans le sens transversal. Répéter l’opération dans le sens avant-arrière. REMARQUE : La sécheuse doit être d’aplomb pour que le système de détection d’humidité...
Page 40 - Retirer la porte de la caisse de la sécheuse
40 INVERSION DU SENS D’OUVERTURE DE LA PORTE Le sens d’ouverture de la porte peut être changé du côté droit au côté gauche, si désiré. REMARQUE : Pour procéder à l’inversion de la porte exactement comme on le voit dans ces instructions, un kit d’inversion de la porte doit être acheté. Pour plus d’in...
Page 43 - NOTES