Page 2 - “IMPORTANT NOTE TO PURCHASER”; FOR YOUR SAFETY; Retain This Manual In A Safe Place For Future Reference; Important
“IMPORTANT NOTE TO PURCHASER” Information must be obtained from your local gas supplier on the instructionsto be followed if the user smells gas. These instructions must be posted in aprominent location near the dryer. FOR YOUR SAFETY Do not store or use gasoline orother flammable vapors andliquids ...
Page 3 - CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON OR NEAR THE DRYER(S).; CAUTION; DRYERS SHOULD NEVER BE LEFT UNATTENDED WHILE IN OPERATION.; DO NOT DRY MOP HEADS IN THE DRYER.; WARNING
IMPORTANT YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GASSUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THEMACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, ORTESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and HealthAdministration) STANDARDS. WARNING CHILDRE...
Page 5 - Table of Contents
SECTION ISAFETY PRECAUTIONS ......................................................................................... 2 SECTION IISPECIFICATIONS/COMPONENT IDENTIFICATION ..................................... 4 A. Specifications ...........................................................................
Page 6 - SECTION I; SAFETY PRECAUTIONS; service panels removed. PERSONAL INJURY OR FIRE COULD RESULT.
2 Maytag Co. 113184-7 SECTION I SAFETY PRECAUTIONS WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. WARNING: The dryer must never be operated with any of the back guard...
Page 7 - WARNING: PERSONAL INJURY OR FIRE COULD RESULT SHOULD THE DRYER; create a fire hazard.; WARNING: YOU MUST DISCONNECT AND LOCK OUT THE ELECTRIC SUPPLY
113184-7 Maytag Co. 3 WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubber materials. Drying in a heated basket (tumbler) may damageplastics or rubber and may be a fire hazard. 7. A program should be established for the inspection and c...
Page 8 - SECTION II; SPECIFICATIONS/COMPONENT IDENTIFICATION; notice or obligation.; Electric
4 Maytag Co. 113184-7 MAXIMUM CAPACITY (DRY WEIGHT) 7 5 lb 3 4 . 0 2 k g TUMBLER DIAMETER 4 4 - 1 / 2 ” 11 3 . 0 3 c m TUMBLER DEPTH 2 4 - 7 / 8 ” 6 3 . 1 8 c m TUMBLER VOLUME 2 2 . 4 0 c u f t 6 3 4 . 3 0 L TUMBLER/DRIVE MOTOR 1 hp * 0 . 7 5 k W BLOWER/FAN MOTOR N / A DOOR OPENING (DIAMETER) 3 1 - ...
Page 9 - Specifications – Gas
113184-7 Maytag Co. 5 Specifications – Gas NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.
Page 10 - B. COMPONENT IDENTIFICATION
6 Maytag Co. 113184-7 B. COMPONENT IDENTIFICATION 1. Dryer Front View Illus. No. Description 1 Controls 2 Control (top access) Door Assembly 3 Main Door Assembly 4 Lint Compartment Area (lint screen located behind door) 5 Data Label and Installation Label
Page 12 - SECTION III; INSTALLATION PROCEDURES; A. LOCATION REQUIREMENTS
8 Maytag Co. 113184-7 SECTION III INSTALLATION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In theabsence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1-LATEST EDITION (National Fu...
Page 13 - months, inspect the exhaust ducting and remove any lint buildup.
113184-7 Maytag Co. 9 9. The dryer must be installed with adequate clearance for air openings into the combustion chamber. CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6 months, inspect the exhaust ducting and remove any lint buildup. IMPORTANT: The drye...
Page 15 - C. DRYER ENCLOSURE REQUIREMENTS; NOTE: Allowances must be made for opening the control door.
113184-7 Maytag Co. 11 C. DRYER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of12-inches (30.48 cm) (18-inches [45.72 cm] or more is recommended for ease of installation, maintenance, andservice) above the dryer outer top, e...
Page 16 - D. FRESH AIR SUPPLY REQUIREMENTS
12 Maytag Co. 113184-7 D. FRESH AIR SUPPLY REQUIREMENTS When the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), andexhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If themake-up air is inade...
Page 17 - E. EXHAUST REQUIREMENTS; CAUTION: IMPROPERLY SIZED OR INSTALLED EXHAUST DUCTWORK CAN
113184-7 Maytag Co. 13 E. EXHAUST REQUIREMENTS 1. General Exhaust Ductwork Information Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductworkwill create excessive back pressure, which results in slow drying, increased use of energy, overheating ofthe...
Page 21 - F. ELECTRICAL INFORMATION; in this manual can result in personal injury or component failure.; NOTE: The use of aluminum wire will VOID THE WARRANTY.; automatically VOID THE WARRANTY.
113184-7 Maytag Co. 17 F. ELECTRICAL INFORMATION 1. Electrical Requirements ALL electrical connections must be made by a properly licensed and competent electrician. Thisis to ensure that the electrical installation is adequate and conforms to local and state regulations or codes.In the absence of s...
Page 22 - GAS ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
18 Maytag Co. 113184-7 GAS ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER) NOTES: A. B. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listedapplian...
Page 23 - FOR 110V APPLICATIONS; Single-Phase Electrical Lead Connections
113184-7 Maytag Co. 19 FOR 110V APPLICATIONS Single-Phase Electrical Lead Connections Black + Positive White or Red + Neutral or L2 Green + Ground 4. Electrical Connections A wiring diagram is located inside the control box for connection data. If local codes permit, power to the dryer can be made b...
Page 25 - TYPE OF GAS
113184-7 Maytag Co. 21 2. Technical Gas Data a . Gas Specifications Shaded areas are stated in metric equivalents * Measured at gas valve pressure tap when the gas valve is on. b. Gas Connections Inlet connection ---- 3/4” N.P.T.Inlet supply size ---- 3/4” diameter pipe (minimum)Btu/hr input -------...
Page 26 - erratic operation of the burner ignition system.
22 Maytag Co. 113184-7 3. Piping/Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATESTEDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (LiquidPropane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas P...
Page 28 - I. PREOPERATIONAL TEST
24 Maytag Co. 113184-7 5. GAS MODELS – be sure that ALL gas shutoff valves are in the open position. 6. Be sure ALL back panels (guards) and electric box covers have been replaced. 7. Check ALL service doors to assure that they are closed and secured in place. 8. Be sure the lint drawer is securely ...
Page 30 - K. SHUTDOWN INSTRUCTIONS
26 Maytag Co. 113184-7 J. PREOPERATIONAL INSTRUCTIONS COIN MODELS 1. Microprocessor Controller (Computer) a . When the microprocessor controller (computer) is in the ready state, the liquid crystal display (L.C.D.) screen will display “Ready, Insert $XX.XX (amount) to Start”. b. Insert coin(s). Once...
Page 31 - SECTION IV; ROUTINE MAINTENANCE; WARNING: LINT FROM MOST FABRICS IS HIGHLY COMBUSTIBLE. THE; SUGGESTED CLEANING SCHEDULE; WARNING: TO AVOID HAZARD OF ELECTRICAL SHOCK, DISCONTINUE
113184-7 Maytag Co. 27 SECTION IV ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint fromvarious areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best bedetermined from exp...
Page 32 - NOTE: THE ACCUMULATION OF LINT IN THE EXHAUST DUCTWORK CAN; NOTE: DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR.
28 Maytag Co. 113184-7 90 DAYS 1. Remove lint from around basket (tumbler), drive motors, and surrounding areas. 2. Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment. 3. Clean any lint accumulation in and around both the blower and drive motor casing openings. ...
Page 33 - SECTION V; DATA LABEL INFORMATION
113184-7 Maytag Co. 29 SECTION V DATA LABEL INFORMATION When contacting the Maytag dealer, or the Maytag Co., certain information is required to ensure properservice/parts information. This information is on the data label, which is affixed to the left side panel area behindthe top control (access) ...
Page 34 - SECTION VI; PROCEDURE FOR FUNCTIONAL CHECK
30 Maytag Co. 113184-7 SECTION VI PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1. Microprocessor Controller (Computer) Board a . Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer. b. Start the drying cycle by pressi...