Page 2 - Proper installation is the responsibility of the owner.; CABINET DIMENSIONS; (Depth with dryer door open 90; Tools needed for installation
2 Printed in U.S.A.. • Impreso en los Estados Unidos • Stampato negli Stati Uniti (revised 06/23/04) 22001460 Proper installation is the responsibility of the owner. HOWEVER, SERVICE CALLS PERFORMED AS A RESULT OF POOR SET-UP, ADJUSTMENTAND CONNECTION ARE THE RESPONSIBILITY OF THE INSTALLER. Make su...
Page 3 - IMPORTANT TO INSTALLER; LOCATION CONSIDERATIONS; ALCOVE OR CLOSET INSTALLATION; ) of open area equally distributed. If this closet contains both a
3 IMPORTANT TO INSTALLER Please Read The Following Instructions Carefully Before Starting To Install The Dryer. TheseInstructions Should Be Retained For Future Reference. REMOVE THE DOOR FROM ALL DISCARDED APPLIANCES SUCH ASDRYERS TO AVOID THE DANGER OF A CHILD SUFFOCATING. LOCATION CONSIDERATIONS T...
Page 4 - MOBILE HOME INSTALLATION; ) of unobstructed opening is required. All mobile home; EXHAUSTING; DUCTING REQUIREMENTS
4 MOBILE HOME INSTALLATION The installation of the dryer in mobile homes must conform to the Manufactured HomeConstruction and Safety Standard Title 24 CFR, Part 32-80 {formerly the Federal standardfor Mobile Home Construction and Safety, Title 24, HUD (Part 280), 1975} for the UnitedStates,) or CSA...
Page 5 - The exhaust system meets all local, state and national codes.
5 • Secure joints with duct tape. Do not use screws. • DO NOT EXHAUST DRYER INTO ANY WALL, CEILING, CRAWL SPACE OR ACONCEALED SPACE OF A BUILDING, GAS VENT, ANY OTHER COMMON DUCT ORCHIMNEY. THIS COULD CREATE A FIRE HAZARD FROM LINT EXPELLED BY THEDRYER. • Plastic flexible duct can kink, sag, be punc...
Page 6 - NONEXHAUSTED INSTALLATIONS; IF THE DRYER IS NOT EXHAUSTED TO THE OUTSIDE, SOME FINE; ELECTRICAL REQUIREMENTS; Wiring diagram is located inside the lower kick panel.; Export models; last page of installation instructions.; GROUNDING; ELECTRIC MODELS
6 The static pressure in any exhaust system must not exceed 0.48 inches ofwater column, or be less than 0. This can be measured with the dryer running with a manometer at the point where theexhaust duct connects to the dryer. A no heat setting should be used. The dryer tumblershould be empty and the...
Page 7 - ELECTRICAL CONNECTIONS; BEFORE OPERATING OR TESTING,; follow all grounding instructions in Grounding
7 If a power cord is not used and the electric dryer is to be permanently wired, the dryer mustbe connected to a grounded metal, permanent wiring system; or an equipment-groundingconductor must be run with the circuit conductors and connected to the equipment-groundingterminal. ELECTRICAL CONNECTION...
Page 8 - ELECTRIC MODELS – Canada Only; It is not permissible to convert a dryer in Canada to 208 volts.; REPLACEMENT PARTS AND ACCESSORIES
8 • If the dryer is to be installed in a mobile home or an area where local codes do not permitgrounding through neutral, only a 4 conductor power cord, rated and terminated as above,may be used. ELECTRIC MODELS – Canada Only • A 120/240 volt, 60 Hz AC approved electrical service fused through a 30 ...
Page 9 - INSTALLATION; Parts and literature are packaged inside of dryer drum.; To Install...; Review Electrical Requirements Section.
9 INSTALLATION Parts and literature are packaged inside of dryer drum. To Install… 1. Move dryer to an appropriate location for installation. Consider installing the dryer before the washer in side-by-side installations, to allow access to gas, electrical and exhaust connections.Lay two of the carto...
Page 11 - HOUSEHOLD INSTALLATION ACCESSORIES
11 7. Check All Connections: At this time, make sure all gas connections (on gas models), exhaust and electricalconnections are complete. Plug dryer in, and check operation by using the check listbelow. FINAL INSTALLATION CHECK LIST q Dryer is plugged into electrical outlet and is properly grounded....
Page 12 - ADDITIONAL INSTRUCTIONS FOR EXPORT MODELS; EXPORT ELECTRIC MODELS; strain relief must be used.
12 ADDITIONAL INSTRUCTIONS FOR EXPORT MODELS (Not U.S. or Canada) Contact the distributor that sold the appliance or: Maytag International, 8700 W. Bryn Mawr Avenue, Chicago, Illinois USA 60631, 773-714-0100, forinformation on product, shipping damage, replacement parts and accessories. Maytag dryer...