Contents Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3Product Description ....
Page 3 - IMPORTANT SAFEGUARDS; READ ALL INSTRUCTIONS BEFORE USING; SAVE THIS MANUAL FOR REFERENCE
2 IMPORTANT SAFEGUARDS READ ALL INSTRUCTIONS BEFORE USING DANGER - To reduce the risk of electrocution: 1. Always unplug this product immediately after using. 2. Do not use while bathing. 3. Do not place or store product where it can fall or be pulled into a tub or sink. 4. Do not place in or drop i...
Page 4 - General Information; the following standards:; FOR US AND CANADA ONLY; blood circulation and reduce the edema.; mixture with air or with oxygen or nitrous oxide.
3 1. Introduction This manual should be used for initial set up of the system and for reference purposes. 1.1 General Information LumexAir systems use most advanced technologies and mattress materials to deliver the best quality, comfort and whisper-quiet operations to you and your customers. Most s...
Page 5 - Product Description; Pump and Mattress System; Air tube connector
4 2. Product Description 2.1 Pump and Mattress System 1. Mattress 2. Pump unit 3. Air tube connector 4. Control Panel The system consists of a high volume airflow blower and numerous large air loss holes on the mattress to achieve the true low air loss therapy. It also provides excellent ventilation...
Page 6 - NOTE: Please cover the mattress with a cotton sheet to; Connect air tube connector from air mattress to the pump unit; NOTE: Check and ensure the air tubes are not kinked or
5 3. Installation 3.1 Unpacking The pump unit and mattress are packaged in a separate box to secure its contents inside. Unpacking these boxes to remove the pump unit and mattress and check for any damage, which may have occurred in shipping. If there are damages, please contact your dealer immediat...
Page 7 - NOTE; Make sure the pump unit is suitable for the local power; CAUTION: The pump can only be applied to the mattress; Then turn the main power switch ON. The power switch is; NOTE: Ensure the CPR connectors are sealed completely.
6 4. Plug into main electrical outlet. NOTE 1. Make sure the pump unit is suitable for the local power voltage. 2. The plug also serves as the disconnect device CAUTION: The pump can only be applied to the mattress recommended by the manufacturer. Do not use it for any other purpose. 5 Then turn the...
Page 8 - NOTE: Always read the operating instructions before use.; Control Button; POWER; mattress. The default setting is at a comfort range, level 6, for the; ALARM MUTE; Enable and disable the audible alarm feature. Press this button to; PANEL LOCK; the panel, press this button and hold it for 3 seconds.; LOW PRESSURE INDICATOR; Yellow light - pressure has not reached the preset setting.
7 4. Operation NOTE: Always read the operating instructions before use. 4.1 Function Description: Control Button Function Description POWER Two conditions: 1. To turn on control unit. It takes approximately 1 minute to inflate the mattress. The default setting is at a comfort range, level 6, for the...
Page 9 - AUTOFIRM; and then it will return to default setting automatically.; STATIC; with very low air pressure support and true low air-loss therapy.; PULSATION; the mattress between two comfort levels at 2 cycles per minute.; COMFORT RANGE; The mattress has 6 comfort ranges. Use UP/DOWN button to adjust
8 Control Button Function Description AUTOFIRM For maximum inflation of mattress. All other functions are disabled unless this button is pressed again. This mode will last for 20 minutes and then it will return to default setting automatically. STATIC For true low air-loss therapy mode, similar to a...
Page 11 - qualified dealer for repair.; Power Failure Alarm; the pump unit. All parts should be air dried thoroughly before use.; CAUTION: Do not immerse or soak pump unit.
10 NOTE: If the pressure level is consistently low, check for any leakage at air cells or connecting tubes. If necessary, replace any damaged cells or tubes or contact local qualified dealer for repair. If the control unit is equipped without audible alarm feature, the Low Pressure Indicator will fl...
Page 12 - Air Filter Replacement
11 6. Storage 1. Pull the CPR tags and make sure all cells are deflated. 2. Lay the mattress out flat and upside down. 3. Protect the air tube coupler by putting it in the inner side of mattress. 4. Roll the mattress from the head end towards the foot end. 5. Foot-end straps can then be stretched ar...
Page 14 - Technical Description
13 Pump Specification Power Supply (Note: See rating label on the product) 120V AC 60Hz, 1A (For 120V system)230VAC 50Hz, 7W ( For 230V system) Fuse Rating 5A (For 120V system), T3A ( For 230V system) Dimension 37 x 27 x 13 (cm) or 14.4" x 10.5" x 5" Weight 4.5 kg or 9.9 lb Environment T...
Page 15 - Graham-Field Health Products
U.S.A., Corporate Headquar ters: Graham-Field Health Products 2935 Northeast Parkway Atlanta, Georgia 30360 telephone: 800-347-5678, 770-447-1609 fax: 800-726-0601, 678-291-3232 http://www.grahamfield.com