Page 2 - The NMEA 2000 female red to female Blue adapter cable allows users; Tools and Supplies
2 Some sonar or GPS display units may require a software upgrade to display NMEA 2000 data correctly. For free software upgrades or additional information on the LowranceNet NMEA 2000 ® network system, visit our web site, www.lowrance.com. The EP-60R consists of a red cable connector and the sensor ...
Page 3 - LowranceNET Node Kit for a NMEA 2000 network. Includes a 2-foot; Setup and Installation of NMEA 2000 Networks,; Installation
3 LowranceNET Node Kit for a NMEA 2000 network. Includes a 2-foot extension cable, T connector and two 120-ohm terminators. For complete instructions on setting up a new NMEA 2000 network or expanding an existing one, see the other document packed with your EP-60R Fuel Flow, " Setup and Installa...
Page 4 - Push the fuel line onto the hose barb, then tighten the hose clamp.; must; From
4 Cut the fuel hose where you intend to install the EP-60R sensor. Slide a clamp over the hose coming from the tank, then push the hose onto the bottom (inlet) hose barb. Seat the hose flush against the sensor housing, then tighten the hose clamp. Attach the hose leading to the engine on the top (ou...
Page 5 - Connecting to a NMEA 2000 Network; There are two types of LowranceNet red connectors: the single T; Network Backbone and Network Nodes
5 Connecting to a NMEA 2000 Network A NMEA 2000 network is a communications link between two or more devices that transfer NMEA 2000 information. LowranceNET is the NMEA 2000 networking system developed by Lowrance Electronics. A NMEA 2000 network functions like the phone wiring in a house. If, for ...
Page 6 - NMEA 2000 network node located at the end of a NMEA 2000 backbone.; Adding a Network Node
6 NMEA 2000 network node located at the end of a NMEA 2000 backbone. NOTE: If you have a double T Connector on your network that is not attached to a device, you must cap the unused connector with a NMEA 2000 cap. This will protect the pin connectors from corrosion. The NMEA 2000 cap looks like a te...
Page 7 - In this example, a new device is added to the NMEA 2000 bus by; Additional Network Information; came packed with this document.
7 In this example, a new device is added to the NMEA 2000 bus by installing a T connector between a T connector and a terminator at the end of the backbone (network bus). Additional Network Information For more information on creating or expanding a network refer to the NMEA 2000 network setup bookl...
Page 8 - Notes
Page 9 - Configuration & Calibration; Boat Setup; To execute Boat Setup:
9 LMF-200: EP-60R Configuration & Calibration This section covers how to use the EP-60R Fuel Flow with a LMF-200 Multi-function gauge. NOTE: You will notice the LMF-200 does not have an Exit key. Menus will time out after a preset amount of time (3, 5, 10 or 15 seconds). The default setting is 5...
Page 10 - Boat Setup Reset; Hit menu to reset Eng/Tnk; EP-60R Fuel Flow Configuration
10 3. Select the tank you want to set up and press MENU , which will open the Tank Size window. 4. Use the UP and DOWN keys to input the number of gallons the tank will hold and press MENU . Repeat steps 3 and 4 for each additional tank. After all tanks have been set up, you will be directed to the ...
Page 13 - Reset; Hit Menu to Rst Values.; EP-60R Fuel Flow Calibration; Fuel Flow Accuracy
13 5. You will be taken back to the Bus Devices list, where the fuel flow you selected (formerly Port FFlow) will be listed as Stbd FFlow. If the newly configured fuel flow is not shown, refresh the Bus Devices list. Reset The Reset command in the Fuel Flow level menu will clear the sensor’s configu...
Page 14 - Hit Menu if Tank filled up
14 To customize Fuel Manager page: 1. With the Fuel Manager page displayed on the main display, press MENU , select C USTOMIZE and press MENU . 2. Highlight USD (Fuel Used) and press MENU . If your unit is configured for more than one tank, the Select Tank menu will appear. (If your engine-tank conf...
Page 15 - Reset Calibration; Hit Menu to Rst the Cal
15 9. The Recalibration (The Recal?) menu will appear with two options: Yes and No. Select Y ES and press MENU . NOTE: If you do not have the fuel remaining source set to Eng/FFlow, the recalibration message will not appear. 10. The Filled Quantity window will appear. Use the UP and DOWN keys to inp...
Page 17 - Hit Menu to Rst Trip F.; Fuel Warning
17 To Reset Trip Fuel (Rst trip f) 1. Press MENU , use the UP and DOWN keys to select S YSTEM S ETUP and press MENU . Highlight F UEL MNGR and press MENU . 2. Select R ST TRIP F (Reset Trip Fuel) and press MENU . The Select Engine menu will appear with up to four options. Select the desired engine o...
Page 18 - Displaying data from fuel flow; Page Screen Rotation
18 6. Use the UP and DOWN keys to input the desired percentage of tank capacity and press MENU . Let the menus time out to return to the main display. NOTE: To turn off a fuel warning, repeat Steps 1-4, then select O FF from the Level Percentage window mentioned in Step 5. Press MENU . Repeat these ...
Page 19 - Customizing Pages; and
19 Autoscroll feature if you want the pages to automatically scroll across the screen. Refer to your LMF -200 manual for more information about Autoscroll. Adding a page: 1. Press MENU , use the UP and DOWN keys to select P AGES and press MENU , which will open the Pages menu with the following opti...
Page 20 - or if your; Hit
20 menu will appear, allowing you to display data from a single engine or show data from all engines. (If you select F UEL R ANGE (RNG) or if your unit is configured for one engine, you will be taken back to the main display.) 5. Select the desired engine or, to display data from all engines, highli...
Page 22 - Press ENTER to reset Eng/Tnk Cfg; Fuel Remaining Source
22 Boat Setup Reset If you want to access the Setup screen (Boat Setup) after an engine- tank configuration has been chosen you will have to reset the configuration to default settings. To reset engine-tank configuration: 1. Press MENU , highlight S YSTEM S ETUP and press ENTER . 2. Choose E NG /T A...
Page 23 - Bus Devices highlighted in the System Setup menu (left). Searching; Press Enter to Configure Fuel Flow Snsr.
23 1. Press MENU , use the UP and DOWN keys to select S YSTEM S ETUP and press ENTER . 2. Highlight B US D EVICES and press ENTER . The Bus Devices list will appear. Bus Devices highlighted in the System Setup menu (left). Searching Bus Devices window (center) with Bus Devices list (right). 3. Selec...
Page 25 - NOTE; Press Enter to add Fuel Manager
25 EP-60R Fuel Flow Calibration The factory calibration settings for the EP-60R Fuel Flow should be within 3 percent, so calibration will not be necessary in most cases. NOTE : The Fuel Remaining Source must be set to fuel flow for the unit to correctly display fuel level information. Follow the ins...
Page 27 - Press Enter to reset the Calibration; Refill Tank; Press; Partial Fill
27 2. Highlight B US D EVICES and press ENTER . Highlight the fuel flow you want to reset and press ENTER . 3. Select R ESET C AL from the fuel flow menu and press ENTER . The following message will appear: Press Enter to reset the Calibration . 4. Press ENTER to set calibration back to default sett...
Page 28 - Reset Seasonal
28 NOTE: When using the Partial Fill command, you will only be able to input into the gauge, an amount of fuel less or equal to the fuel used figure. The unit will not allow you to enter a fuel amount greater than the fuel used figure. 4. Use the UP and DOWN keys to input the amount of fuel added to...
Page 29 - Press Enter to reset Seasonal Fuel
29 To reset seasonal fuel: 1. Press MENU , select S YSTEM S ETUP and press ENTER . 2. Highlight F UEL S ETUP and press ENTER . 3. Select R ESET S EASONAL and press ENTER . The Select Engine menu will appear with up to four options. (If you have one engine, the reset seasonal fuel message (Step 4) wi...
Page 30 - Displaying data from a fuel flow; Press Enter to
30 To set an Engine Warning (Alarm): 1. Press MENU , use the UP and DOWN keys to highlight S YSTEM S ETUP , and press ENTER . 2. Highlight E NGINE W ARNINGS and press ENTER . The Engine Warnings menu will appear with up to five options, including Off and All Engines. The default setting is All Engin...
Page 31 - or if your unit is configured for one engine, you will be directed
31 To customize Single Digital page: 1. After the Single Digital page has been added to the page screen rotation, use the ENTER and EXIT keys to display it on the main screen. 2. Press MENU , use the UP and DOWN keys to select C USTOMIZE and press ENTER . The data menu will appear. 3. Highlight Fuel...
Page 32 - or if your unit is configured for one engine, you will be taken; Reset Values; Press Enter to Reset Device Values.
32 data from a single engine or from all engines on the vessel. (If you select F UEL R ANGE or if your unit is configured for one engine, you will be taken back to the Position menu.) 5. Select the desired engine or, to display data from all engines, highlight Vessel and press ENTER . You will be ta...
Page 33 - The LMS-525cDF is one of many Lowrance display units that may be; Bus Setup
33 Display Unit: EP-60R Configuration & Calibration All NMEA 2000 capable Lowrance sonar and sonar/GPS combo display units can be used to configure and calibrate your EP-60R Fuel Flow sensor on a NMEA 2000 network. The LMS-525cDF is one of many Lowrance display units that may be used to configur...
Page 34 - Bus Setup highlighted on the NMEA 2000 menu (left). Bus Setup; ENT; Engine & Tank Configuration
34 Bus Setup highlighted on the NMEA 2000 menu (left). Bus Setup selected on Networking menu (right). The Engine-Tank Configuration and Tank Select menus as well as the Tank Size dialog box are located on the bottom half of the Bus Configuration menu. The Set Configuration button — positioned next t...
Page 35 - Engine/1Tank highlighted on Engine and Tank Configuration; Are you sure
35 Setting Engine-Tank Configuration: 1. Press MENU twice, highlight NMEA 2000 or N ETWORKING and press ENTER . 2. The NMEA 2000 menu will appear with five options: Bus Setup, Fuel Management, NMEA 2000 Alarms, Waypoint Sharing and Backlight Synchronization. Choose B US S ETUP and press ENTER . 3. S...
Page 36 - Device Configuration Menu
36 menu. To configure or calibrate most devices, you will select it on the NMEA 2000 Devices list and press ENTER . This will open its Device Configuration menu. Bus Configuration menu with five items displayed on the NMEA 2000 Devices list. Engine-Tank Configuration and Tank Select menus are at the...
Page 37 - Device Name
37 EP-60R Fuel Flow Configuration When configuring your fuel flow, you will open its Device Configuration menu where you can access the Location and Advanced Options menu. You can also change your fuel flow's device name. Device Name You can change how your fuel flow will be displayed on your unit's...
Page 38 - Location; Are you sure you wish to change this device's; Unconfiguring an EP-60R Fuel Flow
38 5. Highlight the device and press ENTER . The Device Configuration menu will open. The device name will be reset to its default setting. Press EXIT repeatedly to return to the main display. Location The Location menu allows you to select a configuration name that matches the location of the engin...
Page 41 - Are you sure you wish to Fill Tank?; Engine Operations
41 4. Highlight F ILL T ANK and press ENTER . The following confirmation message will appear: Are you sure you wish to Fill Tank? NOTE : You must use the unit’s Fill Tank command when filling your fuel tank to keep the fuel flow updated with correct information on the amount of fuel in the tank. 5. ...
Page 44 - Are you sure you wish to change this device's configuration?
44 Alarm Status Tab The Alarm Status tab is the second tab at the top of the NMEA 2000 Alarms page. When an alarm has been set for a device, the alarm and its current status will be shown on the Alarm Status window. To view Alarm Status: 1. Press MENU twice, select NMEA 2000 or N ETWORKING and press...
Page 47 - LOWRANCE ELECTRONICS
47 LOWRANCE ELECTRONICS FULL ONE-YEAR WARRANTY "We," "our," or "us" refers to LOWRANCE ELECTRONICS, INC., the manufacturer of this product. "You" or "your" refers to the first person who purchases this product as a consumer item for personal, family or househo...
Page 48 - How to Obtain Service...; ...outside Canada and the USA:; Accessory Ordering Information
48 How to Obtain Service… …in the USA: Contact the Factory Customer Service Department. Call toll-free: For Lowrance: 800-324-1356. For Eagle: 800-324-1354 8 a.m. to 5 p.m. Central Standard Time, M-F Lowrance Electronics and Eagle Electronics may find it necessary to change or end their shipping pol...