LINDY CPU Switch Smart GERMAN Kurzhandbuch, Einführung FEATURES Der LINDY CPU Switch SMART unterstützt Monitorauflösungen bis 1900x1440 bis 75Hz sowie DDC Monitorerkennung. Der LINDY CPU Switch benötigt bei Kabellängen unter 5m kein Netzteil. W erden größere Kabellängen benötigt, so sollte ein optio...
Page 4 - Guía rápida de instalación y funcionamiento; INSTALACIÓN RÁPIDA; RESUMEN DE LA GUÍA DE FUNCIONAMIENTO; Información sobre seguridad
LINDY CPU Switch Smart SPANISH Guía rápida de instalación y funcionamiento INSTALACIÓN RÁPIDA Desconecte todos los ordenadores y conéctelos a los puertos VERDE CLARO en la parte posterior del LINDY CPU Switch Smart. Para mayor comodidad se recomiendan cables combinados 3-en-1 teclado/vídeo/ratón. Ta...
Page 5 - Consignes de sécurité; Téléchargez une version Français complète de ce manuel :
LINDY CPU Switch Smart FRENCH Guide d’installation rapide et mode d’emploi INSTALLATION RAPIDE Mettez tous vos ordinateurs hors tension et raccordez-les aux ports VERT CLAIR à l'arrière du LINDY CPU Switch Smart. Les câbles clavier/vidéo/souris Adder 3-in-1 sont recommandés pour des raisons pratique...
Page 6 - Guida di installazione rapida e funzionamento; INSTALLAZIONE RAPIDA; individuali adatti.; SOMMARIO GUIDA OPERATIVA; Informazionoi riguardanti la sicurezza
LINDY CPU Switch Smart ITALIAN Guida di installazione rapida e funzionamento INSTALLAZIONE RAPIDA Spegnere tutti i computer e collegarli alle porte VERDE CHIARO sul retro del LINDY CPU Switch Smart. Per facilità consigliamo i cavi LINDY combinati 3-in-1 tastiera/video/mouse. Sono pure disponibili ca...
Page 8 - About this manual; LINDY CPU Switch Smart - Installation and Use; Safety information; optional power adapter and its accessories.
LINDY CPU Switch Smart Installation and Use Page 1 About this manual LINDY CPU Switch Smart - Installation and Use Third edition (June 2001) (c) 2001 LINDY Electronics Ltd. Part No. LY0039/3 www.lindy.com Part No. 32298 LINDY CPU Switch Smart 2 Port Part No. 32299 LINDY CPU Switch Smart 4 Port All r...
Page 10 - Warranty
LINDY CPU Switch Smart Installation and Use Page 3 Warranty LINDY Electronics Ltd warrants that this product shall be free from defects in workmanship and materials for a period of one year from the date of original purchase. If the product should fail to operate correctly in normal use during the w...
Page 11 - Radio Frequency Energy; to electromagnetic disturbances.
LINDY CPU Switch Smart Installation and Use Page 4 Radio Frequency Energy Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances. European EMC directive 89/3...
Page 12 - Contents; Resetting the LINDY CPU Switch Smart without disconnecting
LINDY CPU Switch Smart Installation and Use Page 5 Contents 1. Introduction .................................................................................... 6 1.1 Key features........................................................................................... 6 1.2 Package contents .........
Page 13 - applications
LINDY CPU Switch Smart Installation and Use Page 6 applications .......................................................................................... 25 4. LINDY CPU Switch Smart configuration options ........................ 27 4.1 Screen saver time delay .........................................
Page 15 - Package contents
LINDY CPU Switch Smart Installation and Use Page 8 Includes screen saver, auto-scan and variable hotkey options. Supports Microsoft IntelliMouse, IntelliMouse Explorer and other common wheel mice. Mouse restoration functions to enable ‘hot plugging’ of certain systems. Keyboard, mouse and LINDY CPU ...
Page 16 - Product information
LINDY CPU Switch Smart Installation and Use Page 9 1.4 Product information Figure 1 - LINDY CPU Switch Smart front view Figure 2 - LINDY CPU Switch Smart rear view (4 port model) Figure 3 - Remote control pad / display (optional accessory - part 32255)
Page 18 - Mounting the LINDY CPU Switch Smart; that is some distance from the monitor and peripherals.; Connecting your devices
LINDY CPU Switch Smart Installation and Use Page 11 2.2 Mounting the LINDY CPU Switch Smart The LINDY CPU Switch Smart has been designed for use on a desktop or shelf in close proximity to the user’s monitor and peripherals. The optional remote controller may be used if you wish to locate the LINDY ...
Page 19 - recognised by the computers when they are switched on.; Configuring your PCs; Refer to the list of supported drivers in section 2.1.; Configuring the LINDY CPU Switch Smart; EEPROM memory and are retained when the power is disconnected.; To enter configure mode at power on:
LINDY CPU Switch Smart Installation and Use Page 12 connected computers. Failure to switch the LINDY CPU Switch Smart and computers on in the correct order can lead to the mouse and/or keyboard not being recognised by the computers when they are switched on. 2.4 ‘Interface powered’ operation without...
Page 20 - To exit configure mode type:
LINDY CPU Switch Smart Installation and Use Page 13 keyboard cable and so will power itself on when the attached PC is switched on or when the optional power adapter is connected. Do not release the key until the LINDY CPU Switch Smart displays ’C’ to show that it has entered configure mode. To ente...
Page 24 - states are an obvious example of this process.
LINDY CPU Switch Smart Installation and Use Page 17 system which allows you to disconnect and re-connect the shared mouse without powering down the system (although this is generally not advisable) - see section 2.10 for details. Keyboard and mouse mode switching - The LINDY CPU Switch Smart keeps a...
Page 27 - computers and removing the optional power adapter.; Step 4 - Ensure that the LINDY CPU Switch Smart is powered on; The display should now show:; Step 5 - Run the upgrade program; the upgrade is in progress.
LINDY CPU Switch Smart Installation and Use Page 20 you may reset the LINDY CPU Switch Smart by powering off all the attached computers and removing the optional power adapter. Step 4 - Ensure that the LINDY CPU Switch Smart is powered on Ensure that the LINDY CPU Switch Smart is powered on. It is n...
Page 28 - firmware version query function.
LINDY CPU Switch Smart Installation and Use Page 21 You may check the new firmware version by entering configure mode and using the firmware version query function.
Page 30 - Using the LINDY CPU Switch Smart; will remain locked until a valid password is entered.; Front panel key and remote controller; operation will cause the next channel to be selected.
LINDY CPU Switch Smart Installation and Use Page 23 3. Using the LINDY CPU Switch Smart This section explains the general operation of the LINDY CPU Switch Smart. W e recommend that you read this section before starting to use the product. 3.1 Power on status At power on the LINDY CPU Switch Smart s...
Page 32 - Keyboard hotkey control; the ports by holding down the hotkeys and repeatedly pressing TAB.
LINDY CPU Switch Smart Installation and Use Page 25 3.4 Keyboard hotkey control LINDY CPU Switch Smart can be conveniently controlled by selecting channel, autoscan mode or security locking from the keyboard. All of the hotkey control commands are invoked by holding down the two hotkeys and then pre...
Page 33 - To select channel 2:; To ’tab through’ channels:; ED
LINDY CPU Switch Smart Installation and Use Page 26 Examples of common hotkey sequences (assuming CTRL + ALT hotkey option): To select channel 2: press ED release ED To ’tab through’ channels: press ED Y release Y press Y release Y press Y release YED 3.5 Mouse control Computers may conveniently be ...
Page 34 - Cascading LINDY CPU Switch Smarts
LINDY CPU Switch Smart Installation and Use Page 27 3.6 RS232 control LINDY CPU Switch Smart can be controlled by a remote RS232 device. To select a channel the data rate of the sending device must be set to 1200 baud, 8 bits, no parity and 1 stop bit. No handshaking is used by the LINDY CPU Switch ...
Page 35 - A typical cascade of two LINDY CPU Switch Smarts
LINDY CPU Switch Smart Installation and Use Page 28 A typical cascade of two LINDY CPU Switch Smarts 3.8 Synchronising LINDY CPU Switch Smarts for multiple video head applications Multiple LINDY CPU Switch Smarts may be connected together so that they operate in a synchronised manner. Synchronised o...
Page 36 - application
LINDY CPU Switch Smart Installation and Use Page 29 channel if it receives the same command on its serial interface. Consequently, by linking the serial interfaces a master unit may be made to automatically switch a daisy chain of slaved units as shown in the diagram below. The slave units will requ...
Page 43 - CPU Switch Junior OSDs should be set to EF.; L5 – Allow the mouse to run at any speed (default); L6 – Don't allow the mouse to run at very slow speeds
LINDY CPU Switch Smart Installation and Use Page 36 4.8 Cascade query code The LINDY CPU Switch Smarts use a special ‘query code’ to detect whether or not they are connected to another LINDY CPU Switch Smart. By default your LINDY CPU Switch Smart uses query code AD. LINDY CPU Switch Junior OSD (ano...
Page 45 - computers can now be switched on.
LINDY CPU Switch Smart Installation and Use Page 38 4.10 Exit configure mode W hen you have finished configuring any special options, simply type ‘E’ followed by (return) to exit configure mode and return to normal operation mode. The attached computers can now be switched on.
Page 46 - IMPORTANT NOTE; experience problems try using shorter cables.; also operate at distances of 20 metres.; A2. LINDY CPU Switch Smart to PCs 1 to 4; Cable specifications:
LINDY CPU Switch Smart Installation and Use Page 39 Appendix A. Cable and connector specifications IMPORTANT NOTE The maximum cable lengths supported vary widely between devices and cables. It may be possible to use cables that are longer than those specified below with certain PCs and peripherals b...
Page 47 - have these DDC lines connected.; and may not be compatible with the LINDY CPU Switch Smart
LINDY CPU Switch Smart Installation and Use Page 40 have these DDC lines connected. Keyboard and PS/2 mice - 6 pin mini-DIN male connector to 6 pin mini-DIN male connector with all lines connected straight through (1-1,2-2 etc.). If the PC has a 5- pin DIN AT style keyboard connector you will need a...
Page 48 - A3. Options port pin assignments; Other pins to be left unconnected
LINDY CPU Switch Smart Installation and Use Page 41 Recommended cables: 3-in-1 keyboard, video and mouse combination cable - For convenience, neatness and high video quality we recommend the LINDY brand 3-in-1 combination cables. These cables are constructed with tri-coax video links to ensure that ...
Page 49 - A.4 Flash upgrade cable connection
LINDY CPU Switch Smart Installation and Use Page 42 A.4 Flash upgrade cable connection The cable connections shown below are to connect either COM1 or COM2 of a PC to the LINDY CPU Switch Smart to allow flash upgrades. A.5 RS232 synchronisation cable pin assignments The cable connections shown below...
Page 50 - Problem Solving
LINDY CPU Switch Smart Installation and Use Page 43 Appendix B. Problem Solving Problem: Poor video quality with smearing fuzziness or ripple. Action: Use screened coaxial video cables to connect your devices. Problem: Mouse does not move cursor on screen. Action: Ensure that the mouse and computer ...