Page 2 - Engineering Data; WEIGHT; Performance

2 3 2 1 20 40 60 80 100 120 140 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Static Pressure (in w .g.) A ir Flow ( c fm ) 3 - High Speed 2 - Medium Low Speed1 - Low speed Engineering Data Model RNC120F THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE The cross-flow heat recovery core transfers heat between th...

Page 3 - Dimensions; inches; Dimensions; inches

ALL DUCT CONNECTION COLLARS ARE 5" DIAMETER FRESH AIR FROM OUTSIDE EXHAUST AIR FROM BUILDING FRESH AIR TO BUILDING EXHAUST AIR TO OUTSIDE TOP VIEW SERVICE CLEARANCE FROM BOTTOM OF UNIT IS MINIMUM 3'0" FRESH AIRFROM OUTSIDE EXHAUST AIRFROM BUILDING EXHAUST AIR TO OUTSIDE FRESH AIR TO BUILDING...

Page 4 - ERV System Control

4 Engineering Data Model 120ERV Latent Recovery/Moisture Transfer Core The cross flow energy recovery core transfers heat and water vapor between the two airstreams. It is easily removed for cleaning and service. MOTORS AND BLOWERS Each Air stream has an independent motorized impeller. 3 speed opera...