Page 3 - THE FIREPLACE; INTRODUCTION; PARTS REqUIRED; Fireplace model: Cambria; TABLE OF CONTENTS; benefit and enjoyment available from your new fireplace.; OPTIONAL EqUIPMENT
THE FIREPLACE INTRODUCTION The Cambria™ wood-burning fireplace is a mid-efficient, heat radiating fireplace. You will receive a lifetime of comfort and enjoyment from your fireplace provided it is installed, maintained and operated properly. • Please read these instructions and retain this manual fo...
Page 5 - Outside Air on Page 16). When operating; GAS LOG INSTALLATION; pipe is allowed. Consult your local authority.
Building a Fire A) To start a fire, place several crumpled up balls of newspaper in the firebox. Place small dry pieces of kindling on top of the paper, criss-crossing the kindling so that there are air spaces in between. The kindling should be placed at the center of the firebox so as to allow for ...
Page 6 - Dealing With a Chimney Fire; Note: For better performances, we recommend; DOOR FRAME FINISH CARE; Figure 5; WARNING
IMPORTANT CAUTIONS A. Do not block the hot air vents to the fire- place as this will cause the fireplace to overheat. B. Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or ‘freshen up’ a fire in this fireplace. Keep all such liquids well ...
Page 7 - Figure 6; Door Opening Adjustment; WARNINGS; The fireplace cannot be oper-; DOOR ADJUSTMENT; Figure 7; Door
Figure 6 The gaskets’ air-tightness can be adjusted us- ing the adjustment screw located on the slider stoppers (see Figure 8). Turning the screws clockwise will shorten the travel of the slider and increase the pressure on the door side gaskets. This may lead to the doors being harder to lock, so a...
Page 8 - Table 1; GLASS CARE; Glass Replacement; Do not operate the unit with cracked or broken; Glass Cleaning; Installation on Page 6) and lay them on a clean
Gasket Part # Dimensions qty Around the door PR-SR1823N 58-3/4” 5/8” dia. 2 Table 1 Figure 10 Figure 11 Unscrew the nuts to change the bearings Door Angle (hang)Adjustment Screw NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 8 GLASS CARE Glass Replacement The glass used for the Cambria™ firepl...
Page 9 - FIREPLACE INSTALLATION; Locating The Fireplace; Page 25. Next, measure the area occupied by
FIREPLACE INSTALLATION Locating The Fireplace The best location to install your fireplace is determined by considering the location of windows, doors, and the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the hearth extension and the mantel, and tak...
Page 10 - COLD CLIMATE INSTALLATIONS; Climates where temperatures will fall below; Elevated Fireplaces
Figure 14 - Hearth Extension and Clearances Fireplace Figure 13 - Hearth Extension Requirements Framing, Facing And Mantel The construction of the framing, facing, and mantel must be in accordance with the stan- dards and the following illustrations (Figures 15 through 20): A. Frame the fireplace us...
Page 11 - Figure 15 - Framing Dimensions; Framing Dimensions - Model CambriaTM; FRAMING DIMENSIONS; Rough Framing Face
Notes Due to Lennox Hearth Products ongoing commitment to quality, all specifications, ratings and dimensions are subject to change without notice.All framing dimensions calculated for 1/2" dry wall at the fireplace face. If sheathing the chase or finish- ing with other thickness materials, calc...
Page 12 - Floor; FIREPLACE; IMPORTANT; FACING
Nailing Flanges Four nailing flanges are provided to secure the fireplace to the floor (see figure below). Bend the nailing flanges down so that each flange is flush with the floor, then using nails or screws, secure the fireplace to the floor (2 places each side). The heads of the screws or nails m...
Page 13 - Mantel and Facing; To install the blower,
Optional Fireplace Blower (UZY5) A heat activated blower is sold as an option. It is designed to be located in the back of the fireplace and increase the air flow around the firebox. It uses regular 120V and must be connected to the main electrical circuit by a qualified electrician. An electrical b...
Page 16 - OUTSIDE AIR; It is mandatory to install an outside air connec-; NOTE: We recommend not to exceed 20 feet
OUTSIDE CONNECTION Outside Intake Screw Opening Facing Down Wall Aluminum Tape Plastic Cover Insulation Flexible Pipe Aluminum Tape OUTSIDE AIR It is mandatory to install an outside air connec- tion to the Cambria™ fireplace. The following components are required and are included with the fireplace:...
Page 17 - THE CHIMNEY SYSTEM; Chimney Installation Notes; Table 2 - Flat Roof Framing; CHIMNEY INSTALLATION INSTRUCTIONS
Figure 28 THE CHIMNEY SYSTEM Chimney Installation Notes 1. If possible, install an interior chimney as it will provide better perfor- mance. In areas with continuous temperatures below 0°F (-18°C), the use of an exterior chimney increases the likelihood of operating problems such as low draft, high ...
Page 18 - CHIMNEY INSTALLATION; MODEL AC
Figure 31 Flashing Attic Radiation Shield Firestop Universal Support AC Starter Section AC10SB or AC10SB30 Note: Outside air kits must be installed for both fireplace and AC chimney. Outside Combustion Air Kit From below, install a firestop in each ceiling/ floor separation through which the chimney...
Page 19 - Roof Down Slope Hole Size; OFFSET CHIMNEY INSTALLATION
Roof Down Slope Hole Size Degree Of Slope Secure Temp ASHT+ Nova Temp HT6103+ AC Roof Pitch 10” 10” 0 * 16-3/8” (416 mm) 17” (432 mm) 2/12 16-5/8” (422 mm) 17-1/4” (438 mm) 4/12 17-1/4” (439 mm) 18” (457 mm) 6/12 18-3/8” (466 mm) 19” (482 mm) 8/12 19-3/4” (500 mm) 20-1/2” (520 mm) 10/12 21-3/8” (542...
Page 20 - Horizontal Offset; Offset Dimensions
Chimney Elbow Offset & Height One Length Between Elbows Two Lengths Between Elbows 8” 12” 18” 24” 36” 48” 8” & 48” 12” & 48” 18” & 48” 24” & 48” 36” & 48” 48” & 48” ASHT+ HT6103+ 10” 15º A 3” (76mm) 4-1/4” (108mm) 5-3/4” (146mm) 7-1/4” (184mm) 10-1/4” (260mm) 13-1/4” (337...
Page 21 - Note: In cold areas it is recommended to; OFFSET CHIMNEY INSTALLATION WITH WALL PENETRATION; Note: This illustration is not to scale. It represents how
Figure 35 OFFSET CHIMNEY INSTALLATION Rain Cap Collar Roof Flashing Offset Support Insulated Wall Radiation Shield Framing 2” x 3” Figure 36 Roof Support Note: In cold areas it is recommended to protect the chimney in a insulated chase. Outside Wall OFFSET CHIMNEY INSTALLATION WITH WALL PENETRATION ...
Page 22 - Table 5; CHIMNEY; Table 6; ANGLED WALL RADIATION SHIELD; Note: 45o angle for Canada only; CHIMNEY SUPPORT INSTALLATION; Universal Roof Support; Table 6 gives maximum height of supported; UNIVERSAL OFFSET SUPPORT
RSMI30, RSMI45, AC10RSMI30 Chimney (10” dia.) Angle Hole Dimension Secure Temp ASHT+ Nova Temp HT6103+ 30º 17-9/16” x 45- 3/4” (446 mm x 1162 mm) Secure Temp ASHT+ Nova Temp HT6103+ 45º Canada only 17-1/2” x 30” (444 mm x 762 mm) AC 30º 17” x 42-1/2” (432 mm x 1080 mm) Table 5 Figure 37 Drywall Insu...
Page 23 - OPTIONAL INSTALLATION ACCESSORIES; Description; CHIMNEY - PARTS AND COMPONENTS LISTS
Installation Accessories Description Cat./Part No. Outside Air Kit (included with fireplace) Outside air kit, UZI UZI UZI outside air kit fireplace adaptor, UZIAD UZIAD Gravity Kit Gravity Kit, Complete double ducting system including: 2 elbows 90º, 2 telescopic lengths, 2 grill supports and 2 black...
Page 24 - Secure Temp ASHT+ 1” High Temp. Insulated Stainless Steel Chimney; Lengths and Misc. Chimney Components
CHIMNEY - PARTS AND COMPONENTS LISTS Secure Temp ASHT+ 1” High Temp. Insulated Stainless Steel Chimney 10” I.D., Double-Wall Stainless Steel, Listed to CAN/UCL-S604 & UL-103HT Description Part/Cat. No. Lengths and Misc. Chimney Components 8” length, 10” Dia., 10L8-N 10L8-N 12” length, 10” Dia., ...
Page 25 - CLEARANCE TO COMBUSTIBLES; • Ceiling: 7’ 6” (2286 mm) measured from the base of the fireplace; Top: Do not fill the space above the fireplace with any material; SPECIFICATIONS; Model; Cambria; mance and safety hazards.
CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation: • Side wall (fireplace front): 24” (457 mm) measured from the fireplace door. • Ceiling: 7’ 6” (2286 mm) measured from the base of the fireplace • Fireplace enclosure: Bottom: 0” Side: 0” to spa...
Page 26 - WARRANTY; to be familiar with its coverage.; PRODUCT REFERENCE INFORMATION; plied from the manufacturer.; The installation date of the appliance.
Printed in Canada © 2008 by Lennox Hearth Products P/N 850,057M REV. E 06/2010 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for f...