Page 2 - Contents; Specifications
Contents Introduction ................................................................................................ 3 Important Safety Information ..................................................................... 4 Pack Contents Checklist .........................................................
Page 3 - Introduction; keep it handy for future reference.
3 Introduction Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly. Having done so, keep it handy for future reference. The Mira Azora is a thermostatic electric shower with separate controls for power selec...
Page 4 - Important Safety Information; on or inside the appliance.; Mains connections are exposed when the cover is removed.
4 Important Safety Information Warning! Follow all warnings, cautions and instructions contained in this guide, and on or inside the appliance. . Products manufactured by us are safe and risk-free, provided that they are installed, used and maintained in good working order, in accordance with our in...
Page 5 - DO NOT
5 Caution! . Read all of these instructions and retain this guide for later use. . The electrical installation must comply to “BS 767 - Requirements for Electrical Installations”, commonly referred to as the IEE Wiring Regulations - Part 7, or any particular regulations and practices, specified by t...
Page 6 - Pack Contents Checklist; Mira Azora; confirm that the parts are included.; Documentation
6 Pack Contents Checklist Mira Azora Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included. 3 x Wall Plugs 3 x Fixing Screws 1 x Mira Azora 1 x Installation and User Guide 1 x Installation Template 1 x Installer Checklist 1 x Guarantee Card...
Page 7 - Mira Energise Electric Shower Fittings; firm that the parts are included.
7 Mira Energise Electric Shower Fittings Tick the appropriate boxes to familiarise yourself with the part names and to con - firm that the parts are included. 2 x Wall Plugs 1 x Slide Bar 1 x Flexible Hose 1 x Handset 2 x Hose Seals 1 x Clamp Bracket Assembly 1 x Soap Dish 1 x Hose Retaining Ring 2 ...
Page 8 - Installation Requirements; Standards and Approvals; pressure of 0.7 bar up to a maximum static inlet pressure of 10 bar.; Do not; fit the
8 Installation Requirements . Plumbing Minimum maintained inlet pressure 70 kPa (0.7 bar). 00 kPa (.0 bar) recommended for satisfactory operation. Maximum static inlet pressure 1000 kPa (10 bar). Minimum static pressure 0 kPa (0. bar) to keep the inlet valve closed. . Electrical The Mira Azora 9.8 k...
Page 9 - be flushed to clear debris before connecting to
9 Avoid layouts where the shower hose will be sharply kinked. This may reduce the life of the hose. A Hose Retaining Ring is supplied to prevent the handset from dropping below the spill-over level of the bath or shower tray, which could lead to contamination from back-siphoning. The supplied Hose R...
Page 10 - exert strain on the terminal block. Ensure that the electrical
0 In a domestic installation, the rating of the electricity supplier’s fuse and the consumer unit must be adequate for the additional demand. All Mira electric showers are high power units, it is essential to contact your electricity supplier to ensure that the supply is adequate for the product. Vo...
Page 11 - Installation; and the appropriate circuit fuse removed, if applicable.; Installation of Mira Azora; Remove the three cover retaining
Double-pole Isolating Switch Consumer Unit Installation Warning! Turn off the electrical and water supplies before proceeding with the installation of the Mira Azora. The electricity must be turned off at the mains and the appropriate circuit fuse removed, if applicable. Note! An installation templa...
Page 13 - Refit the Cover, making sure it is; When fitting the Cover, position
3 Feed cable into Case. Fit Earth sleeve (not supplied) and then strip insulation. Do not twist cable cores. L = BROWN E = GREEN/YELLOWN = BLUE Refit the Cover, making sure it is correctly located. Do not overtighten screws. Caution! Handle glass cover assembly with care. Do not use alternative scre...
Page 15 - Do not overtighten; Place the handset into the slidebar clamp bracket.; Installation of Shower Fittings
5 Decide on a suitable position for the slide bar avoiding buried cables and pipes. Drill the two 7.0 mm fixing holes for the slidebar at 600 mm centres and insert the wall plugs. Assemble the clamp bracket components. Push the plastic slidebar ends into the slidebar. Push the slidebar through the c...
Page 17 - Commissioning; “User Instructions”
7 Commissioning If you are unsure how an electric shower works, please read through the section “User Instructions” before continuing. Turn control to full cold. Turn the water supply fully on. Check for water leaks. Set control to ‘I’. Switch on electrical supply. Press the ‘Start/Stop’ button. Wat...
Page 18 - This is quite normal in use.
8 The temperature will rise further. Adjust temperature as required. Flow rate will adjust automatically. The shower will purge from its tank for a few seconds. Residual water may drain over a few minutes. Set control to ‘III’. 5 - 0 Secs 0 - 5 Secs 3. 5. 4. 6. Press STOP and isolate power. 7. 8. No...
Page 19 - User Instructions; Read the section; “Important Safety Information”
9 User Instructions Read the section “Important Safety Information” first. Note! At the end of every shower make sure that the shower head points into the catchment area. A small amount of water may be retained in the shower handset after the shower has been turned off. This may drain over a few min...
Page 20 - Spray Action; Eco
0 Spray Action The handset spray head has four different spray actions:- Eco, Start, Soothe and Force. The handset operation is described below. . Eco To access the eco setting, turn the spray plate fully clockwise. Water will flow from the outer set of holes at a reduced flow rate. . Start To acces...
Page 21 - Fault Diagnosis
Handset dripping. OFF Any Insufficient Water supply pressure for shut off. Inlet Valve faulty. The minimum static pressure to ensure shut off and prevent dripping is 0. bar. Note: If other appliances are operating, static pressure may drop below 0. bar. Contact local water company. Renew the Flow Va...
Page 23 - Maintenance
3 Appliance fails to produce hot water when set on Medium/ High Heater Setting. ON II/III Heater Tank failure. Contact local water company. Replace. Supply pressure below 0. bar. Contact local water company. Check mains water static pressure. Any ON ON II/III ON II/III Possible failure of the Micros...
Page 25 - Spare Parts List
Page 26 - Accessories
6 DCV-H: An outlet double check valve, designed to prevent the backflow or backsiphonage of potentially contaminated water, through shower controls which are fitted with a flexible hose as part of the outlet shower fitting. Available as an optional accessory from your Mira Showers stockists. Accesso...
Page 27 - Mira Azora Spare Parts Diagram
7 Mira Azora Spare Parts Diagram 405.58 406.7 46.38 46.4 46.48 46.5 87.0 87.8 563.507 563.539 A A A A A A A A A A 563.534 563.59 634.009 563.533 563.537 563.538 B B B B B 563.540 634.05
Page 28 - Mira Energise Shower Fittings Spare Parts List
8 Mira Energise Shower Fittings Spare Parts List 449.03 Slidebar Wall Fixing Assembly 63.73 Hose Seal (x2) 6.65 Slidebar Ends 449.0 Slidebar 449.04 Soap Dish 449.05 Hose 449.0 Clamp Bracket Assembly 563.59 Handset 563.594 Hose Retaining Ring 563.593 Adjuster Ring 450.36 Spray Plate Pack
Page 29 - Dimensions
9 Dimensions 00 mm 77 mm 33 mm 367 mm 69 mm 660 mm 600 mm
Page 30 - Wiring Diagram; Internal Wiring Diagram
30 Wiring Diagram Thermal Cutout Dual Disc Tank Connection Load Inlet Connector Pressure/Power Selector Switch Solenoid Valve Power On L.E.D. START/STOP L e N Internal Wiring Diagram
Page 31 - Customer Services
3 Spare Parts We maintain an extensive stock of spares, and aim to provide support throughout the product’s expected life. Spares can be purchased from approved stockists or merchants (locations on request) or direct from Customer Services. Spares direct will normally be despatched within two workin...