Page 2 - BLE OF CONTENT; FULL ONE YEAR WARRANTY ON HUMIDIFIER; MASTER PROTECTION AGREEMENT; Congratulations on making a smart purchase.; PRODUCT RECORD
Warranty......................................................................2Safety Instruction ....................................................... 3 Before You Start......................................................... 3Understanding Humidity............................................. 4...
Page 3 - SAFETY INSTRUCTION; BEFORE YOU STA
SAFETY INSTRUCTION J RULES FOR SAFE INSTALLATION & OPERATION Read these rules and the instructions carefully. Failure to follow the rules and instructions could cause bodily injury and/or property damage. • Check your local building codes and utility standards. The installation must comply with ...
Page 4 - UNDERSTANDING HUMI; Maximum Sate Recommended
I UNDERSTANDING HUMI I THANK YOU! Thank you for selecting a Sears Humidifier. It will provide years of service if you give it a little care. Humidity can be puzzling, it cannot be seen, heard, touched, smelled or tasted. Many people do not understand what a humidifier will or will not do. Probably t...
Page 5 - TALLAT; TYPICAL REMOTE INSTALLATION; Living Area
TALLAT J SELECTING A LOCATION Carefully study the location that you choose for your humidifier. Install the humidifier so that if the humidifier or any connection should leak, the water will not cause damage. Under no condition is Sears, Roebuck and Co., and the manufacturer, to be held liable for a...
Page 6 - COUNTERFLOW FURNACE INSTALLATION; GRAVITY FURNACE INSTALLATION; sheet metal; If plenum is
COUNTERFLOW FURNACE INSTALLATION For installation of your humidifier on a counterflow furnace, see Fig. 6. Connect the humidifier to the supply air plenum using Remote Installation Kit, Sears Stock No. 9372. COUNTERFLOW FURNACE INSTALLATION SUPPLY AIR PLENUM (Wider Than Stiffener) GRAVITY FURNACE IN...
Page 7 - If plenum is wider than stiffener:
If plenum is wider than stiffener: 2. The five reference hole marks you’ve made on the plenum outline the area that must be cut out. Mark straight lines connecting the five points. WARNING: Wear safety glasses! Be sure not to drill or cut into air conditioner coil or tubing! If electric drill is use...
Page 8 - STANDARD WIRING METHOD
4. Peel off the paper from the back of the gasket and stick the gasket on the return air plenum. 5. Remove the humidistat knob by gently pulling straight out. Remove the cover screw and the cover (Fig. 12). Y 8 . Knob Cover Fig. 12 Mount the humidistat on the return air plenum with the screws, furni...
Page 9 - Alternate Method - 1; For; ALTERNATE WIRING METHODS; Sail
The alternate wiring methods are for your humidifier to operate only when the furnace blower is on and the humidistat is calling for humidity. The method you select will depend on your furnace control system. Find the type of system you have and follow that method. Also, if the method selected requi...
Page 12 - OPERAT; all; HUMIDISTAT; mmsm; If sweating of windows or walls occurs:
I OPERAT J WATER LEVEL CHECK 1 , 2 . Turn on the water supply at the saddle valve. Water should now flow into reservoir. If not, check that saddle valve is open. Check for leaks at all connections. Allow Reservoir to fill and check that water level is correct. The water level should be between the t...
Page 13 - AINTENANC; REGULAR MAINTENANCE
I AINTENANC J Your humidifier will maintain its efficiency for a long period of time. If it is not serviced, damage may result. Service it every mointh. Follow instructions below. Since water conditions vary, it may be necessary to service either more or less often. Establish your own servicing sch...
Page 14 - IF AIR IS TOO DRY (AND WINDOWS ARE NOT
ADJUSTING THE FLOAT 1. Disconnect the water supply at quick disconnect. 2. Remove the float and float arm by pulling out the float pivot pin (Fig. 27). *Floa.t Valve Button Valve Body Float "Reverse button if it has not been used. Replace vtfith new button if both sides are worn. Fig. 27 3. Rais...
Page 15 - PROBLEM
TROUBLESHOOTING Frequently, what seems to be a major problem can be solved very easily. Listed below are the common concerns with any humidifier. Check the simple things first. Remove the front panel and see if there is a crusty, white lime buildup on the media pad. The lime buildup won’t hurt the ...
Page 16 - DESCRIPTION
KENMORE “3000” CENTRAL HUMIDIFIER MODEL NO. 303.9380612 REPAIR PARTS KEY NO. PART NO. DESCRIPTION KEY NO. PART NO. DESCRIPTION 1 21567101 Plenum Stiffener 25 03029401 Locknut 2 STD 610803 Screw (11 Req.) 26 21569101 Float Valve Body (No. 8A X 3/8" Slotted) 27 28110201 Pivot Pin 3 21568601 Upper ...
Page 17 - EXPLODED VIEW
KENMORE “3000” CENTRAL HUMIDIFIER MODEL NO. 303.9380612 REPAIR PARTS EXPLODED VIEW 1 7
Page 18 - Your Home; no matter who made it, no matter who sold it!; Our Home; Para pedir servicio de reparación
Get it fixed, at your home or ours! Your Home For repair-in your home-of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner’s manuals that you need to do-it-yourself. Fo...