2 DRYER SAFETY TABLE OF CONTENTS IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.The dryer must be electrically grounded in accordance w...
Page 4 - TOOLS AND PARTS; Tools needed for all installations:; INSTALLATION REQUIREMENTS; If using a power supply cord:
4 TOOLS AND PARTS Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools needed for all installations: Level #2 Phillips screwdriver Wire stripper (direct wire installations) Parts supplied (all models): Flat-head...
Page 5 - LOCATION REQUIREMENTS; DRYER DIMENSIONS; Spacing for recessed area or closet installation
5 Parts needed: (Not supplied with dryer) Check local codes. Check existing electrical supply and venting. See “Electrical Requirements” and “Venting Requirements” before purchasing parts.Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom...
Page 6 - ELECTRICAL REQUIREMENTS -
6 Mobile home - Additional installation requirements: This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 2...
Page 7 - ELECTRIC DRYER POWER; If connecting by direct wire:; GAS DRYER POWER HOOKUP -
7 4-wire receptacle (14-30R) ELECTRIC DRYER POWER HOOKUP - CANADA ONLY ELECTRICAL REQUIREMENTS It is your responsibility: ■ To contact a qualified electrical installer. ■ To be sure that the electrical connection is adequate and in conformance with Canadian Electrical Code, C22.1-latest edition and ...
Page 8 - WARNING
8 GAS TYPE Natural Gas: This dryer is equipped for use with Natural gas. It is certified by UL for use with propane gas with appropriate conversion. ■ Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your ...
Page 9 - BURNER INPUT REQUIREMENTS; INSTALL LEVELING LEGS; Prepare dryer for leveling legs; For mobile home use
9 3/8" NPT dryer pipe NOTE: For a garage installation, the gas pipe height must be an additional 18" (460 mm) from the floor. GAS SUPPLY CONNECTION REQUIREMENTS ■ Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as ne...
Page 10 - RACCORDEMENT ÉLECTRIQUE – ÉTATS-UNIS SEULEMENT); Electrical Connection Options; Choose electrical connection type; POWER SUPPLY CORD CONNECTION
10 MAKE ELECTRICAL CONNECTION - U.S.A. ONLY (EFFECTUER LE RACCORDEMENT ÉLECTRIQUE – ÉTATS-UNIS SEULEMENT) Electrical Connection Options 1. Choose electrical connection type Power supply cord 4-wire receptacle (NEMA Type 14-30R): Go to Power Supply Cord Connection. 3-wire direct connection: Go to Dir...
Page 11 - -wire Power Supply Cord Connection
11 Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point. Atta...
Page 12 - -wire Power Supply Cord Connection; Connect remaining wires
12 3-wire receptacle (NEMA type 10-30R) 3-prong plug Spade terminals with upturned ends Ring terminals Use where local codes permit connecting cabinet-ground conductor to neutral wire. 3-wire Power Supply Cord Connection 3. Connect remaining wires Connect remaining wires to outer terminal block scre...
Page 13 - DIRECT WIRE CONNECTION; Attach direct wire strain relief; Attach direct wire cable; -wire Direct Wire Connection; Prepare your 4-wire cable for
13 DIRECT WIRE CONNECTION Unscrew the removable conduit connector (A) and any screws from a 3/4" (19 mm) UL Listed strain relief. Put the threaded section of the strain relief (C) through the hole below the terminal block opening (B). Reaching inside the terminal block opening, screw the removab...
Page 15 - Optional 3-wire Connection
15 Connect remaining wires 4. Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw...
Page 16 - Venting Requirements; VENTING; Connect gas supply to dryer; Plan pipe fitting connection; MAKE GAS CONNECTION -
16 Venting Requirements WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances. Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid ...
Page 17 - Optional exhaust installations:; Plan Vent System; Recommended exhaust installations
17 Clamps: ■ Use clamps to seal all joints. ■ Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape. Vent products can be purchased from your dealer. For more information, see “Assistance or Service...
Page 18 - Special provisions for mobile homes:; Connect vent to exhaust hood; Install Vent System; Install exhaust hood; Vent System Chart; CONNECT INLET HOSES; Turn cold water off, remove and
18 Special provisions for mobile homes: Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home. Terminate exhaust vent outside. Moblie Home Exhaust installation Connect vent to exhaust hood 2. Vent must fit over the exhaust ho...
Page 19 - Attach long hose to dryer fill valve
19 Tighten couplings 3. Using pliers, tighten the couplings with additional two-thirds turn. NOTE: Do not overtighten. Damage to the coupling can result. Attach short hose and “Y” connector 2. Attach 2 ft (0.6 m) inlet hose to cold water faucet. Screw on coupling by hand until it is seated on faucet...
Page 20 - LEVEL DRYER; CONNECT VENT; Connect vent to exhaust outlet; Move dryer to final location; Level Dryer
20 LEVEL DRYER Not Level LEVEL Not Level Check levelness of dryer from side to side. Repeat from front to back. NOTE: The dryer must be level for the moisture sensing system to operate correctly. CONNECT VENT 1. Connect vent to exhaust outlet Using a 4" (102 mm) clamp, connect vent to exhaust ou...
Page 22 - REVERSE DOOR SWING; Remove door from dryer cabinet; Reverse the strike
22 REVERSE DOOR SWING You can change your door swing from a right-side opening to a left-side opening, if desired. 1. Place a towel or soft cloth on top of dryer or work space to avoid damaging the surface. Remove door from dryer cabinet 1. Open the dryer door. 2. Using a T25 ® screwdriver, remove s...
Page 23 - Remove the door assembly
23 Remove the door assembly 1. Lay the door on a flat, covered surface, with the inside of the door facing up. Remove the 3 plugs with a flat-head screwdriver. There is a cut out to stick the screwdriver under to pop out. 2. Remove the 10 screws from the dryer door and set screws off to the side. 3....
Page 25 - TROUBLESHOOTING
25 10. Add inside door panel back into the dryer door by sliding the top into the top trim piece and then lower door down. Then press down on the corners to snap into place with the hinges lined up with the hinge holes. 11. Install 6 hinge screws and the other 4 screws. 12. Install hinge covers and ...
Page 26 - Kenmore; Customer Care Hotline; To schedule repair service or order parts; Para pedir servicio o ordenar piezas; com; For service in Canada Au Canada pour service
Kenmore ® Customer Care Hotline To schedule repair service or order parts Para pedir servicio o ordenar piezas 1-844-553-6667 www. kenmore. com For service in Canada Au Canada pour service 1-800-469-4663 ® W11101364A ©2017 Sears Brands, LLC 03/17