Page 2 - DESCRIPTION; Accessories; CONTENTS
3 "Plug-and-Play" redefined Electronic setting of all important parameters, automatic levelling (only for VGP 9033-1G/9041) as well as remote configuration via HMS or DOCSIS monitoring ensure the shortest start-up and maintenance times. The copy function enables one to copy all settings and ...
Page 3 - ACCESSORIES, BLOCK DIAGRAM, DELIVERY STATUS; Delivery status; Output insert position; for operation with one output
DETAILS, ACCESSORIES, BLOCK DIAGRAM, DELIVERY STATUS 4 Delivery status F-type test socket internal (-20 dB) F-type test socket internal (-20 dB) Output insert position Insert position "Forward 1" e.g. for additional C-line pre-emphasis Connection socket for hand-held unit HTE 10 Insert posit...
Page 4 - Technical Data; Simple, yet effective; local insertion max. 10 A totally
Technical Data DESCRIPTION VGO 939-1G/ VGF 939-1G DATA Type VGF 9030 VGF 9040 VGP 9033-1G VGP 9041 Order no. 24410108 24410109 24410103 24410054 FORWARD PATH Frequency range MHz 85-862 85-862 85-1000 85-862 Gain (at 1000 MHz) dB 33 40 33 40 Return loss dB 19-1.5 dB/oct. Frequency response (85-1000 M...
Page 6 - House connection amplifiers; In the latest generation, the
1 1 Technical Data DESCRIPTION VOS 952-1G/953-1G DATA Type VGO 939-1G VGF 939-1G Notes Order no. 24410101 24410100 Locally fed Remotely fed FORWARD PATH Frequency range MHz 85-1000 Gain dB 40 Gain setting range, interstage ³ ) dB 32-40 Amplitude response dB ±0.5 85-1000 MHz, at 25 °C Amplitude respo...
Page 7 - • The insert position is fitted with a
1 2 DETAILS, ACCESSORIES, BLOCK DIAGRAM, DELIVERY STATUS Accessories Delivery status 1 3 LED (Power supply function) ) Input insert position e.g. for de-emphasis equaliser Insert position for monitoring transponder (not included in delivery scope) F-type test socket for the return path (-10 dB) F-ty...
Page 8 - DATA
1 4 1 5 DATA Technical Data 1) Adjustable with 2 slide switches in 1 dB steps 2) CENELEC: 42 channels 3) When the 15 MHz high pass is connected, the dynamic range increases by 3 dB Type VOS 952-1G VOS 953-1G Notes Order no. 24410098 24410099 Locally fed Remotely fed FORWARD PATH Frequency range MHz ...
Page 10 - ERZ 940 – De-emphasis equaliser
EAC 90-1G, 93-1G, 94-1G – Tap-off cards 1 1 9 Type EAC 90-1G EAC 93-1G EAC 94-1G EBC 90-1G Order no. 24510116 24510115 24510114 24510113 Frequency range MHz 5-1000 5-1000 5-1000 5-1000 Through loss ¹) 5-610 MHz dB < 1.3 < 2.1 < 0.5 < 3.6 Through loss ¹) 610-862 MHz dB < 1.3 < 2.3 &...
Page 11 - We are pleased to advise you:; Antennen · Electronic; F-type cable fittings; PG 11 connectors
We are pleased to advise you: 99811514/1/0810/JH/Pf T echnical data subject to modification. Technical data repr esent typical values. Antennen · Electronic The products described must only be installed by qualified specialists. Please consult the provided instruction manuals for the safety instruct...