Page 2 - COOKTOP SAFETY; You; DANGER; WARNING: Gas leaks cannot always be detected by smell.
2 COOKTOP SAFETY You can be killed or seriously injured if you don't immediately You can be killed or seriously injured if you don't follow All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what canhappen if the instructions are...
Page 3 - INSTALLATION REQUIREMENTS; Tools and Parts; Tools needed; Location Requirements; Mobile Home - Additional Installation Requirements
3 INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools needed Parts supplied NOTE: The cooktop is manufactured for use with Natural gas. To convert to LP gas, see the “G...
Page 4 - Venting Requirements; IMPORTANT: This cooktop must be exhausted outdoors.
4 Product Dimensions 48" (121.9 cm) Cooktop Cabinet Dimensions NOTE: Access must be provided to remove and empty grease container. Cutout Dimensions Venting Requirements IMPORTANT: This cooktop must be exhausted outdoors. ■ Do not terminate the vent system in an attic or other enclosed area. ■ U...
Page 5 - Venting Methods; Concrete Slab Installations - Exhaust Through Wall
5 ■ Make sure there is a minimum of 18" (45.7 cm) of straight vent between the elbows if more than one elbow is used. ■ Elbows too close together can cause excess turbulence that reduces airflow. ■ Do not use a 5" (12.7 cm) elbow in a 6" (15.2 cm) or 3 ¹⁄₄ " x 10" (8.3 x 25.4 cm)...
Page 6 - Example vent system; Electrical Requirements; WARNING; Explosion Hazard
6 Example vent system NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance. Electrical Requirements IMPORTANT: The cooktop must be electrically grounded in accordance with local codes and ordinances, or in the absence of local...
Page 7 - Type of Gas; Gas Supply Line; Flexible metal appliance connector:; Rigid pipe connection:; Gas Pressure Regulator
7 Type of Gas Natural Gas: This cooktop is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas. ■ This cooktop is factory set for use with Natural gas. If converting to LP gas, see the “LP Gas Conversion” instructions provided in the packag...
Page 8 - INSTALLATION INSTRUCTIONS; Install Cooktop; Rotate Blower - Optional; Excessive Weight Hazard
8 INSTALLATION INSTRUCTIONS Install Cooktop Decide on the final location for the cooktop. 1. Open carton as instructed on product packaging. 2. Remove shipping materials and tape from cooktop. 3. Remove the removable grease filter by lifting the filter out. 4. For island or peninsula installations, ...
Page 9 - Make Gas Connection; Typical flexible connection.
9 Make Gas Connection 1. Apply pipe-joint compound made for use with Natural and LP gas to the smaller thread ends of the flexible connector adapters (see C and G in the following illustration). 2. Attach one adapter to the gas pressure regulator and the other adapter to the gas shutoff valve. Tight...
Page 10 - Burner Ignition; Check Operation of Surface Burners; Adjust Flame Height; Adjust Air Shutter
10 Burner Ignition Check Operation of Surface Burners Push in and turn the surface burners control knobs to light. The surface burner flame should light within 4 seconds. The first time a surface burner is lighted it may take longer that 4 seconds to light because of air in the gas line. Check the f...
Page 11 - Complete Installation; Check that all parts are now installed. If there is an extra part,; Use a mild solution of liquid household cleaner and warm; If you need Assistance or Service:
11 On any burner, closing the air shutter too far will cause the flame to become soft and yellow tipped. Opening the air shutter too wide will cause the flame to blow away from the burner ports. Proper adjustment will produce a sharp, clearly defined, even blue flame. Complete Installation 1. Check ...
Page 12 - GAS CONVERSIONS; LP Gas Conversion; Turn the manual shutoff valve to the closed position.; To Convert Gas Pressure Regulator; Remove the access cap by using a wrench, turning the; Remove spring retainer from the cap by pushing against the
12 GAS CONVERSIONS IMPORTANT: Gas conversions from Natural gas to LP gas must be done by a qualified installer. LP Gas Conversion 1. Turn the manual shutoff valve to the closed position. 2. Unplug cooktop or disconnect power. To Convert Gas Pressure Regulator 1. Remove the access cap by using a wren...
Page 13 - Natural Gas Conversion
13 To Convert Surface Burners 1. Remove Natural gas orifice hoods. Locate the LP gas orifice hoods from the package attached to the outer plenum area of this appliance. 2. To convert from Natural gas to LP gas, apply a ½" open-end wrench to hex section of orifice hood. Turn counterclockwise to r...
Page 15 - SÉCURITÉ DE LA TABLE DE CUISSON; AVERTISSEMENT
15 SÉCURITÉ DE LA TABLE DE CUISSON Risque possible de décès ou de blessure grave si vous ne suivez pas immédiatement les instructions. Risque possible de décès ou de blessure grave si vous ne suivez pas les instructions. Tous les messages de sécurité vous diront quel est le danger potentiel et vous ...
Page 16 - EXIGENCES D'INSTALLATION; Outillage et pièces; Outils nécessaires; Exigences d’emplacement
16 EXIGENCES D'INSTALLATION Outillage et pièces Rassembler les outils et pièces nécessaires avant d’entreprendre l’installation. Lire et observer les instructions fournies avec chacun des outils de la liste ci-dessous. Outils nécessaires Pièces fournies REMARQUE : La table de cuisson est conçue pour...
Page 20 - Spécifications électriques; Spécifications de l'alimentation en gaz; Type de gaz; Conversion pour l'alimentation au propane :
20 Spécifications électriques IMPORTANT : La table de cuisson doit être correctement reliée à la terre en conformité avec les codes et règlements locaux en vigueur, ou en l'absence de tels codes, avec le National Electrical Code, ANSI/NFPA 70 ou le Code canadien des installations électriques, CSA C2...
Page 21 - Canalisation de gaz; Raccord métallique flexible :; Détendeur de gaz
21 Canalisation de gaz ■ Installer une canalisation de gaz rigide de ¾" (1,9 cm) jusqu'à l'emplacement d'installation de la table de cuisson. L'emploi d'une canalisation de plus petit diamètre sur un circuit plus long peut causer une déficience du débit d'alimentation. On doit utiliser un compos...
Page 22 - INSTRUCTIONS D’INSTALLATION; Installation de la table de cuisson; Rotation du ventilateur – facultative.; Risque du poids excessif
22 INSTRUCTIONS D’INSTALLATION Installation de la table de cuisson Déterminer l’emplacement final de la table de cuisson. 1. Ouvrir le carton tel que stipulé sur l'emballage du produit. 2. Enlever les matériaux de transport et le ruban adhésif de la table de cuisson. 3. Retirer le filtre à graisse a...
Page 23 - Raccordement au gaz; Appliquer un composé d'étanchéité pour tuyauteries conçu; Raccordement typique par raccord flexible
23 Raccordement au gaz 1. Appliquer un composé d'étanchéité pour tuyauteries conçu pour une utilisation avec du gaz naturel ou du gaz propane sur l'extrémité filetée la plus petite des adaptateurs de raccord flexible (voir C et G dans l'illustration suivante). 2. Fixer un raccord d'adaptation sur le...
Page 24 - Achever le raccordement; Allumage des brûleurs; Contrôle du fonctionnement des brûleurs de surface; Risque de choc électrique
24 Achever le raccordement 1. Ouvrir le robinet d’arrêt manuel sur la canalisation de gaz. Le robinet est ouvert lorsque la poignée est parallèle au conduit d’alimentation en gaz. 2. Vérifier tous les raccordements en les badigeonnant d’une solution de détection des fuites non corrosive approuvée. L...
Page 25 - Achever l'installation; Si vous avez besoin d’assistance ou de service :
25 S'il est nécessaire de régler la taille des flammes pour le débit thermique minimum : 1. Allumer 1 brûleur et le tourner au réglage le plus bas. 2. Ôter le bouton de commande. 3. Immobiliser la tige de commande avec une pince. Utiliser un petit tournevis à lame plate de ¹⁄₈ " (3 mm) pour fair...
Page 26 - CONVERSIONS POUR CHANGEMENT DE GAZ; Conversion pour l'alimentation au propane; Conversion du détendeur
26 CONVERSIONS POUR CHANGEMENT DE GAZ IMPORTANT : L'opération de conversion de l'appareil (pour l'alimentation au gaz propane au lieu du gaz naturel) doit être exécutée par un installateur qualifié. Conversion pour l'alimentation au propane 1. Tourner le robinet d'arrêt manuel pour le placer à la po...
Page 27 - Achever l’installation; Conversion pour l'alimentation au gaz
27 3. Remplacer par les gicleurs aux couleurs correctes (fournis). Voir le “Tableau de sélection des gicleurs pour gaz propane”. Tourner dans le sens horaire pour installer. Visser le gicleur jusqu'à ce que son extrémité se trouve à ¹¹⁄₁₆ " de la face de l'injecteur de montage. Voir l’illustrati...