Page 2 - COOKTOP SAFETY; WHAT TO DO IF YOU SMELL GAS:
2 COOKTOP SAFETY WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. – WHAT TO...
Page 3 - INSTALLATION REQUIREMENTS; Tools and Parts; Tools Needed
3 INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools Needed Adjustable wrench Tape measure Marker or pencil Pipe wrench Flat-blade screwdriver 15/16" (24 mm) combi...
Page 4 - Location Requirements; Mobile Home - Additional Installation Requirements
4 Parts Supplied Check that all parts are included. ■ Gas pressure regulator ■ Burner grates ■ Burner bases and burner caps ■ Griddle drip tray (on griddle models) ■ Foam tape ■ Propane orifice package (W10393255) ■ Conversion label (W10393342) NOTE: The cooktop is manufactured for use with Natural g...
Page 6 - Cabinet Requirements
6 Cabinet Requirements Size Model A* Cooktop Cutout to Back Wall B** Cooktop to Cabinet C Optional Backguard and Upper Cabinet Opening D Cabinet and Countertop E Countertop Only 30" (76.2 cm) JGCP430 1 3 / 4 " (4.4 cm)* 30" (76.2 cm) 30" (76.2 cm) 29 1 / 4 " (74.3 cm) 30" (76...
Page 7 - Type of Gas; Gas Supply Line; WARNING
7 Electrical Requirements IMPORTANT: The cooktop must be electrically grounded in accordance with local codes and ordinances or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.This cooktop is equipped with an electronic ignition ...
Page 8 - Gas Pressure Regulator; INSTALLATION INSTRUCTIONS; Install Cooktop
8 ■ Flexible metal appliance connector: ■ If local codes permit, a new CSA design-certified, 4-5 ft (122-152 cm) long, 5/8" (16 mm) or 3/4" (19 mm) I.D., flexible metal appliance connector may be used for connecting the cooktop to the gas supply line. ■ A 1/2" (13 mm) male pipe thread is n...
Page 9 - Make Gas Connection; To Assemble Pressure Regulator:; Typical flexible connection
9 Make Gas Connection To Assemble Pressure Regulator: 1. Using two or more people, stand the cooktop on its side or back. 2. Connect the flexible stainless steel connector to the pressure regulator using a 1/2" (13 mm) male pipe thread adapter.A combination of pipe fittings must be used to connect...
Page 11 - Flame Height; To Adjust Flame Height:
11 Flame Height The cooktop flame should be a steady blue flame approximately 1/4" (6.4 mm) high. Dual Flame Burner Single Flame Burner To Adjust Flame Height: 1. Unplug cooktop or disconnect power. 2. Remove burner grates. 3. Remove the control knobs. 4. Pull cooktop forward to expose the control...
Page 12 - GAS CONVERSIONS; Propane Gas Conversion; To Convert Gas Pressure Regulator; To Convert Surface Burners
12 19. Check that the control console is flush with the top edge of the cooktop. 20. Replace the two screws on each side of the control console. 21. Push the cooktop back into place in the cutout. 22. Replace the control knobs. 23. Replace burner grates. 24. Plug in cooktop or reconnect power. 25. Te...
Page 14 - Complete Installation; Natural Gas Conversion
14 20. Set the control console back into place on the cooktop. For a proper fit, the flange of the control console must hook over the lip on the front of the cooktop. 21. Check that the control console is flush with the top edge of the cooktop. 22. Replace the two screws on each side of the control con...
Page 15 - STRIP CIRCUITS; Griddle 120V Control Wiring Diagram to Cooktop Stand-Alone
15 To Convert Surface Burners 1. If installed, remove the burner grates. 2. Remove burner cap. 3. Remove the burner base. A B Large Dual Burner A. Burner capB. Burner base A B C Medium Burner A. Burner capB. Burner baseC. Choke (for use with medium burner, Propane gas only) A B Small Burner A. Burne...
Page 16 - WIRING DIAGRAMS; -Burner Cooktop Reignition Wiring Diagram; Cooktop; LEGEND
16 WIRING DIAGRAMS 6-Burner Cooktop Reignition Wiring Diagram Caution : Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. SW1 SW2 SW3 SW4 5 6 3 4 1 2 Power Cord Only To Cooktop Stand-Alon...
Page 17 - -Burner Cooktop Reignition Wiring Diagram; Control Input
17 4-Burner Cooktop Reignition Wiring Diagram Power Cord L N GND GN RD RD WH WH WH WH RD BK BK BK RD RD RD RD RD RD BU BR YL GND Control Input Electrodes Output SW1 SW2 SW3 SW4 L N YL BR BU RD 2 1 4 3 Power Cord Only To Cooktop Stand Alone Version Main - Harness Power Spare Griddle Spare Grill Spare...