Page 2 - WARNING; ACCESSORIES
WARNING Platinum ™ Series 2 Part No 1118353 WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner ’s manuals...
Page 3 - TABLE OF CONTENTS
Part No 1118353 3 Platinum ™ Series TABLE OF CONTENTS TABLE OF CONTENTS ACCESSORIES .................................................. 2REGISTER YOUR PRODUCT .............................. 4SPECIAL NOTES ............................................... 5LABEL LOCATION ...................................
Page 4 - REGISTER YOUR; Register ONLINE at
TABLE OF CONTENTS Platinum ™ Series 4 Part No 1118353 TABLE OF CONTENTS SECTION 6—MAINTENANCE .......................... 23 Routine Maintenance ........................................................................ 23 Cleaning the Cabinet Filter........................................................
Page 5 - SPECIAL NOTES; NOTICE; SIGNAL WORD
SPECIAL NOTES Part No 1118353 5 Platinum ™ Series SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. Refer to the following table for definitio...
Page 6 - CAUTION
SPECIAL NOTES Platinum ™ Series 6 Part No 1118353 CAUTION “Caution: Federal law restricts this device to sale or rental by or on order of a physician, or any other practitioner licensed by the law of the State in which he/she practices ...
Page 7 - LABEL LOCATION
LABEL LOCATION Part No 1118353 7 Platinum ™ Series LABEL LOCATION HomeFill II Compatib le I/O Operating Instructions (See Operator's Manual) Alarms (See Operator's Manual) WARNING - RISK OF FIRE NO SMOKING - Keep ALL sources of ignition out of the room inwhich this product is located and away from a...
Page 8 - SECTION 1—GENERAL GUIDELINES; To Reduce the Risk of Burns,
SECTION 1—GENERAL GUIDELINES Platinum ™ Series 8 Part No 1118353 SECTION 1—GENERAL GUIDELINES In order to ensure the safe installation, assembly and operation of the Platinum concentrator these instructions MUST be followed. WARNING This section contains imp...
Page 9 - Operating Information
SECTION 1—GENERAL GUIDELINES Part No 1118353 9 Platinum ™ Series Operating Information For optimum performance, Invacare recommends that each concentrator be on and running for a minimum of 30 minutes at a time. Shorter periods of operation may red...
Page 11 - SECTION 2—FEATURES
SECTION 2—FEATURES Part No 1118353 11 Platinum ™ Series SECTION 2—FEATURES Oxygen Outlet Flowmeter Oxygen Purity Indicator Lights (SensO 2 model only)/ Fault and Power Indicator Lights (LX model only) Power Switch Circuit Breaker Elapsed Time Meter Cabinet Filter (one of two shown) REAR VIEW ACCESSO...
Page 12 - SECTION 3—HANDLING; Unpacking; Inspection
SECTION 3—HANDLING Platinum ™ Series 12 Part No 1118353 SECTION 3—HANDLING The concentrator should ALWAYS be kept in the upright position to prevent cabinet damage while being transported. If the concentrator is to be reshipped by common carrier, a...
Page 13 - SECTION 4—TYPICAL PRODUCT PARAMETERS
SECTION 4—TYPICAL PRODUCT PARAMETERS Part No 1118353 13 Platinum ™ Series SECTION 4—TYPICAL PRODUCT PARAMETERS *NOTE: Stated concentration levels achieved after initial warm ‐ up period (approximately 30 minutes). Electrical Requirements: 120 VAC ± 10% (132 VAC/108 VAC), 60 Hz ...
Page 16 - SECTION 5—OPERATING INSTRUCTIONS; SECTION 5—; OPERATING; Introduction
SECTION 5—OPERATING INSTRUCTIONS Platinum ™ Series 16 Part No 1118353 SECTION 5— OPERATING INSTRUCTIONS Introduction Your oxygen concentrator is intended for individual use indoors. It is an electronically operated device that separates oxygen from room air. ...
Page 17 - Plug in Power Cord; Filling the Humidifier
SECTION 5—OPERATING INSTRUCTIONS Part No 1118353 17 Platinum ™ Series Set-Up Plug in Power Cord Plug in power cord to an electrical outlet. POLARIZED PLUG WARNING As a safety feature, this appliance may have a polarized plug (one blade is wider than the ...
Page 18 - Humidifier Compartment
SECTION 5—OPERATING INSTRUCTIONS Platinum ™ Series 18 Part No 1118353 FIGURE 5.2 Humidifier Compartment 3. Remove the filter access door located on the side of the concentrator. Insert a flathead screwdriver in the plate groove on the top edge of the...
Page 19 - Attaching the Oxygen Tubing; Power Switch
SECTION 5—OPERATING INSTRUCTIONS Part No 1118353 19 Platinum ™ Series 7. Attach oxygen tubing from the humidifier bottle to oxygen outlet connector on the oxygen concentrator (FIGURE 5.4). 8. Attach the cannula/patient supply tubing to the humidifier b...
Page 20 - Flowrate
SECTION 5—OPERATING INSTRUCTIONS Platinum ™ Series 20 Part No 1118353 Flowrate NOTE: For this procedure, refer to FIGURE 5.6 on page 20. 1. Turn the flowrate knob to the setting prescribed by your physician or therapist. CAUTION Never set the flow gr...
Page 21 - Front Panel Indicators - Units with SensO; Initial Startup of the Concentrator
SECTION 5—OPERATING INSTRUCTIONS Part No 1118353 21 Platinum ™ Series Front Panel Indicators - Units with SensO 2 NOTE: For this procedure, refer to FIGURE 5.7. The SensO 2 feature monitors the purity of oxygen generated by the oxygen concentrator. If purity...
Page 22 - Front Panel Indicators - Units without
SECTION 5—OPERATING INSTRUCTIONS Platinum ™ Series 22 Part No 1118353 Front Panel Indicators - Units without SensO 2 NOTE: For this procedure, refer to FIGURE 5.8. FIGURE 5.8 Front Panel Indicators - Units without SensO2 Initial Startup of the Concentrator NOTE: Concentrator may ...
Page 23 - SECTION 6—MAINTENANCE; Routine Maintenance; Cleaning the Cabinet Filter
SECTION 6—MAINTENANCE Part No 1118353 23 Platinum ™ Series SECTION 6—MAINTENANCE WARNING The Invacare concentrators are specifically designed to minimize routine preventive maintenance. Only qualified personnel should perform preventive maintenance on the conc...
Page 24 - Cleaning the Cabinet
SECTION 6—MAINTENANCE Platinum ™ Series 24 Part No 1118353 2. Clean the cabinet filters with a vacuum cleaner or wash in warm soapy water and rinse thoroughly. 3. Dry the filters thoroughly before reinstallation. FIGURE 6.1 Cleaning the Cabinet Filter Cleani...
Page 25 - Preventive Maintenance Record
SECTION 6—MAINTENANCE Part No 1118353 25 Platinum ™ Series FIGURE 6.2 Preventive Maintenance Record ON EACH INSPECTION MODEL NO. I R C SERIAL NO. PREVENTIVE MAINTENANCE RECORD INVACARE PLATINUM OXYGEN CONCENTRATOR Record Date of Service Record Elapsed Hours On Hour Meter Clean Cabinet Filter(s) Chec...
Page 26 - SECTION 7—TROUBLESHOOTING GUIDE
SECTION 7—TROUBLESHOOTING GUIDE Platinum ™ Series 26 Part No 1118353 SECTION 7—TROUBLESHOOTING GUIDE SYMPTOM: PROBABLE CAUSE: SOLUTION: Alarm: SHORT BEEPS, LONG PAUSE Concentrator NOT operating,power switch ON. Beep......Beep...... Main Power Loss: 1. Power cord NOT plugged in. 1. Insert plug into o...
Page 28 - NOTES
Page 30 - LIMITED WARRANTY
LIMITED WARRANTY Platinum ™ Series 30 Part No 1118353 LIMITED WARRANTY NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975.This warranty is extended only to the original purchaser who purchases this product when new and unused f...