Page 2 - WARNING; ACCESSORIES WARNING
Recessed Side Entry Bath Tubs 2 Part No 1150695 WARNING DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT FIRST COMPLETELY READING AND UNDERSTANDING THESE INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS OWNER’S MANUALS, SERVICE MANUALS OR INSTRUCTION SHEETS SUPPLIED ...
Page 3 - TABLE OF CONTENTS
TABLE OF CONTENTS Part No 1150695 3 Recessed Side Entry Bath Tubs TABLE OF CONTENTS SPECIAL NOTES ................................................................................ 5LABEL LOCATION ............................................................................ 6TYPICAL PRODUCT PARAMETERS ...
Page 5 - SPECIAL NOTES; NOTICE; THE INFORMATION CONTAINED IN THIS DOCUMENT IS SUBJECT TO; attachments not recommended by the manufacturer.
SPECIAL NOTES Part No 1150695 5 Recessed Side Entry Bath Tubs SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. Refer to the following table for...
Page 6 - LABEL LOCATION
LABEL LOCATION Recessed Side Entry Bath Tubs 6 Part No 1150695 LABEL LOCATION ! "#$% #&$"''() #!#* &+##, #% - './.0'12).3'1"4.( (56('72 %, 8'1 (.(6(723 %8 # 5 &)1'7.00.3+./29:;9 %# ! #% % % #<==9 #< %+ #% 0() >?0 '? 51 !/8.( +(.@8&' # .72; SERIAL NO. MODEL NO. PA...
Page 7 - TYPICAL PRODUCT PARAMETERS
TYPICAL PRODUCT PARAMETERS Part No 1150695 7 Recessed Side Entry Bath Tubs TYPICAL PRODUCT PARAMETERS 3750 3800 MINIMUM SPACE REQUIREMENTS: 7 feet x 6 feet LENGTH EXTERIOR:INTERIOR: 59½ inches 49 inches 59½ inches 49 inches WIDTH EXTERIOR:INTERIOR (SEAT): 31.5 inches 21 inches 31.5 inches 21 inches ...
Page 8 - FEATURES
FEATURES Recessed Side Entry Bath Tubs 8 Part No 1150695 FEATURES 3750 Control Panel Tub Interior Flow Water Thermometer Tub Exterior Service Access Door Door Door Handle Drain Drain Plug Burp Fitting Whirlpool Jets Control Panel (See Above) Shower ON/ OFF Valve Whirlpool Aerator Valve Water Tempera...
Page 10 - SECTION 1—GENERAL GUIDELINES; operation and use of this product.; Important Safety Instructions; are closely supervised at all times.; Installation; SAVE THESE INSTRUCTIONS
SECTION 1—GENERAL GUIDELINES Recessed Side Entry Bath Tubs 10 Part No 1150695 SECTION 1—GENERAL GUIDELINES WARNING SECTION 1 - GENERAL GUIDELINES contains important information for the safe operation and use of this product. Check all parts for shipping damage before using. In case...
Page 11 - Electrical; Grounding; service representative.; conductors suppling this equipment.; Plumbing
SECTION 1—GENERAL GUIDELINES Part No 1150695 11 Recessed Side Entry Bath Tubs Electrical Be certain ALL electrical work is performed by a qualified electrician and is in compliance with local electrical codes. ALL electrical connections are to be water...
Page 12 - Maintenance and Inspection; maintenance to the tub.; Disinfecting
SECTION 1—GENERAL GUIDELINES Recessed Side Entry Bath Tubs 12 Part No 1150695 Maintenance and Inspection DANGER ELECTRICAL SHOCK HAZARD. All disassembly and maintenance of the tub MUST be done by a qualified technician, certified electrician or plumber. Disconnect electrical supply or turn off circu...
Page 13 - Operation
SECTION 1—GENERAL GUIDELINES Part No 1150695 13 Recessed Side Entry Bath Tubs Operation DANGER Keep hair and body away from suction guard when pump is running.The causes, symptoms, and effects of hyperthermia may be described as follows: Hyperthermia occurs when the internal temperature of the body ...
Page 14 - Parts Information; panel in the wall with a minimum size of 16 x 14-inches.; cause the system to malfunction and will void the warranty.
SECTION 2—PARTS AND INSTALLATION Recessed Side Entry Bath Tubs 14 Part No 1150695 SECTION 2—PARTS AND INSTALLATION Parts Information For parts information, please contact ICCG Technical Service at (800) 668 ‐ 2337. About Installation WARNING Access for servicing the tub MUST be p...
Page 15 - Installing the Tub
SECTION 2—PARTS AND INSTALLATION Part No 1150695 15 Recessed Side Entry Bath Tubs Installing the Tub WARNING Protective eye wear MUST be worn when drilling to avoid possible eye injury.The tub MUST be supported by the floor and not the deck. NOTE: For this procedure, refer to FIGURE 2.2,...
Page 18 - Electrical Installation; maintenance to the tub to avoid electrical shock.; a position where a person in the unit cannot reach the timer.
SECTION 2—PARTS AND INSTALLATION Recessed Side Entry Bath Tubs 18 Part No 1150695 Electrical Installation DANGER When using electrical products, basic precautions should always be followed, including the following:RISK OF ELECTRIC SHOCK. Connect the bathtub only to a circuit protected by a ground-fa...
Page 20 - Plumbing Installation; compliance with local codes.; requires water for cooling.
SECTION 2—PARTS AND INSTALLATION Recessed Side Entry Bath Tubs 20 Part No 1150695 Plumbing Installation DANGER Be certain all plumbing work is performed by a qualified plumber and is in compliance with local codes. WARNING Some state and local plumbing codes require the installation of a “reduced pr...
Page 21 - Post Installation Checklist
SECTION 2—PARTS AND INSTALLATION Part No 1150695 21 Recessed Side Entry Bath Tubs 10. Check for leaks in supply or drain lines and check operation of tub. Refer to Operation on page 22. NOTE: Check local codes regarding maximum water temperature allo...
Page 22 - SECTION 3—OPERATION; Overview
SECTION 3—OPERATION Recessed Side Entry Bath Tubs 22 Part No 1150695 SECTION 3—OPERATION Overview The tub is designed to improve the efficiency and environmental safety of your facility ʹ s operation. However, if the tub is not operated or maintained p...
Page 24 - Opening/Closing the Tub Door; DO NOT fill or use tub if door does not; Tub Operation; the water temperature is between 95° F and 105° F (35° C and 41° C) to avoid
SECTION 3—OPERATION Recessed Side Entry Bath Tubs 24 Part No 1150695 Opening/Closing the Tub Door WARNING DO NOT open door when water is in the tub, serious injury could result. NOTE: For this procedure, refer to FIGURE 3.1 on page 24. Opening the Tub Door 1. Place one hand o...
Page 26 - Operating Shower/Massage Wand
SECTION 3—OPERATION Recessed Side Entry Bath Tubs 26 Part No 1150695 Operating Shower/Massage Wand NOTE: For this procedure, refer to FIGURE 3.3. NOTE: STEPS 1 ‐ 3 are to be performed while holding the shower/massage wand over the tub. 1. Turn shower/massa...
Page 27 - Hydromassage; jets otherwise damage to the motor/pump will result.
SECTION 3—OPERATION Part No 1150695 27 Recessed Side Entry Bath Tubs FIGURE 3.4 Filling Tub Hydromassage CAUTION Before starting hydromassage, water level MUST be completely above whirlpool jets otherwise damage to the motor/pump will result. NOTE: For this procedure, refer to FIGURE 3.5...
Page 29 - SECTION 4—MAINTENANCE; Safety Inspection Checklists; Initially
SECTION 4—MAINTENANCE Part No 1150695 29 Recessed Side Entry Bath Tubs SECTION 4—MAINTENANCE NOTE: Every six months or as necessary have a qualified technician perform a thorough inspection and servicing. Routine maintenance will extend the life and ef...
Page 30 - Maintenance Overview; Cleaning the Door Seal Gasket
SECTION 4—MAINTENANCE Recessed Side Entry Bath Tubs 30 Part No 1150695 Maintenance Overview Cleaning the Door Seal Gasket The rubber door seal gasket should remain clean and free of debris. Use a working solution of a commercially available heavy duty clea...
Page 31 - Heavy Duty Cleaning Procedure
SECTION 4—MAINTENANCE Part No 1150695 31 Recessed Side Entry Bath Tubs Heavy Duty Cleaning Procedure WARNING The disinfectant dispensing system has been factory tested and calibrated for use with Invacare disinfectant. The use of any disinfectant with a dilution ratio (½ oz. per gallon) or viscosity...
Page 32 - Calibrating the Disinfectant Flow Meter; dures on disinfectant container.
SECTION 4—MAINTENANCE Recessed Side Entry Bath Tubs 32 Part No 1150695 Calibrating the Disinfectant Flow Meter WARNING The disinfectant dispensing system has been factory tested and calibrated for use with Invacare disinfectant. The use of any disinfectant with a dilution ratio (½ oz. per gallon) or...
Page 34 - Maintenance Record
SECTION 4—MAINTENANCE Recessed Side Entry Bath Tubs 34 Part No 1150695 Maintenance Record DATE MAINTENANCE PERSON TYPE OF MAINTENANCE PERFORMED NOTES
Page 35 - SECTION 5—TROUBLESHOOTING
SECTION 5—TROUBLESHOOTING Part No 1150695 35 Recessed Side Entry Bath Tubs SECTION 5—TROUBLESHOOTING NOTE: If problems are not remedied by the suggested means above, contact an ICCG dealer or technical support. SYSTEM/OPERATION SYMPTOMS FAULTS SOLUTION Hydromassage ...
Page 36 - LIMITED WARRANTY
LIMITED WARRANTY PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975.This warranty is extended only to the original purchaser/user of our products.This warranty gives you specific legal rights and you may also have other ...