Page 6 - Without end of stroke feedback, solenoid control can only; figure 1

PEXXP-XXX-XXX-XXXX (en) Page 6 of 16 SOLENOID GENERAL DESCRIPTION Without end of stroke feedback, solenoid control can only be used to cycle the pump based on timing. The following curves represent the flow rates of a pump based on timed operation of the solenoid at a common operating point of 70 ps...

Page 7 - figure 4; LUBRICATION / SEALANTS; “U” cups and mating parts.

Page 7 of 16 PEXXP-XXX-XXX-XXXX (en) 140 141 200 233 105 107 107 236 135 � 139 138 � 137 � 136 111 419 � 421 420 134 133 429 417 403 415 418 416 407 428 414 413 figure 4  LUBRICATION / SEALANTS   Apply Lubriplate fML-2 grease (94276) to all “O” rings, “U” cups and mating parts. SOLENOID PART LIST...

Page 8 - Set ring may need to be adjusted accordingly.; figure 5

PEXXP-XXX-XXX-XXXX (en) Page 8 of 16 END Of STROKE GENERAL DESCRIPTION With end of stroke feedback from a pressure switch, the solenoid can be used to cycle the pump based on known feed- back that the pump has fully completed each stroke. PRESSURE SWITCH OPERATION A calibration procedure is necessar...