Ingersoll Rand 613100-1 - Manuals
Ingersoll Rand 613100-1 – Manual in PDF format online.
Manuals:
Manual Ingersoll Rand 613100-1
Summary
PAGE 2 OF 6 613100-X OPERATING PRECAUTIONS WARNING HAZARDOUS PRESSURE. Do not exceed maxi- mum operating pressure of 1500 p.s.i. (103 bar) at 150 p.s.i. (10.3 bar) inlet air pressure. PUMP RATIO X INLET PRESSURE TO PUMP MOTOR = MAXIMUM PUMP FLUID PRESSURE Pump ratio is an expression of the relations...
PAGE 3 OF 6 613100-X INSTALLATION (See Figure 1) 1. Attach the (E) pump bracket assembly to the lip of the drum and tighten the retaining screw or bolt the pump bracket assembly to the wall using the 3 holes provided in the back of the (E) pump bracket assembly. 2. Attach the (H) suction tube assemb...
PAGE 4 OF 6 613100-X LOWER PUMP SERVICE PROCEDURES LOWER PUMP DISASSEMBLY NOTE: All threads are right hand. 1. Clamp the lower pump assembly in a vise side ways on the (7) pump body with the material outlet up. 2. With a plastic hammer tap all around the lower end of the (16) suc- tion tube. (Close ...