Page 2 - What to Expect with Your Installation; qualified electrician.; Standard Downrod; than 34° will require an; Read and Save These Instructions; WARNINGS; CAUTIONS
www.HunterFan.com 1.888.830.1326 M0069-01 • 04/30/13 • © Hunter Fan Company What to Expect with Your Installation Know your wiring If you are unfamiliar with wiring, use a qualified electrician. You may need a friend to help you. Check box to see fan weight Assess location 30 inches from blade tip t...
Page 3 - Tools Needed; Ladder
Tools Needed Ladder Power Drill (optional) 9/64” Drill Bit (optional) Screwdrivers Pliers Wire Strippers If mounting to a support structure, you will also need these tools. www.HunterFan.com 1.888.830.1326 3 M0069-01 • 04/30/13 • © Hunter Fan Company
Page 4 - TU; TU; Mounting Options; Use; Standard Mounting; or; Angled Mounting; to hang the fan from a; OPTION; SLIDE; PLACE; FOLD
www.HunterFan.com 1.888.830.1326 4 M0069-01 • 04/30/13 • © Hunter Fan Company 4 If you have an angled ceiling: 1. You will need a longer downrod (sold separately) . 2. If your ceiling angle is greater than 34°, you will also need an Angled Mounting Kit (sold separately) . Guide Touches BOTH Ceiling ...
Page 5 - Ceiling Bracket; OFF; For angled ceilings, point; If you are unable to do this,; Turn P
1.888.830.1326 www.HunterFan.com Ceiling Bracket OFF Make sure all four (4) bumpers are still attached. For angled ceilings, point opening toward peak. Refer to warning w.1 on pg. 2 To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breake...
Page 6 - Preparation; DISCA
www.HunterFan.com 1.888.830.1326 Ceiling Bracket (continued) Preparation 1.888.830.1326 www.HunterFan.com DISCA RD KEEP! Remove the shipping blocks from the motor. Save the screws. They will be needed for blade iron installation. Note: Some fans will have a shipping ring instead of shipping blocks. ...
Page 7 - Downrod; Slid; Option 1; skip to next page; If you need a different downrod length follow these steps:; Steps 1-5 to remove standard downrod pipe; new; pipe
1.888.830.1326 Downrod Slid e Slid e 1 2 3 4 5 6 7 8 9 10 Sold S epar at ely Included Longer Downrod for angled ceilings or ceilings 10’ or higher Shorter Downrod for fans installed close to ceiling Standard Downrod for ceilings 8-10’ high Option 1 Option 2 Option 3 skip to next page If you need a d...
Page 8 - leave at least 8” extending; DO NOT
KEEP! 8” 3/8” CU T & ST R IP (not to scale) Remove the pre-installed setscrew so that the downrod can be inserted. Hand tighten the downrod (at least 4-5 full turns) until it stops. The wires can be cut, but leave at least 8” extending from the top of the downrod. Downrod (continued) 8” 3/8” Tig...
Page 9 - DO NOT PICK THE FAN UP BY THE; Place the downrod
1.888.830.1326 9 M0069-01 • 04/30/13 • © Hunter Fan Company www.HunterFan.com Downrod (continued) DO NOT PICK THE FAN UP BY THE CANOPY OR WIRES. Place the downrod ball into the slot in the ceiling bracket. Put the wires and downrod through the canopy. Let the canopy sit loosely on top of the fan.
Page 10 - Wiring; “common out”) to the white; “neutral in” or
www.HunterFan.com 1.888.830.1326 Wiring Turn the splices upward and push them carefully back through the hanger bracket into the outlet box. Spread the wires apart, with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box. Refer to CAUTION c....
Page 11 - Canopy; lifted into place, the canopy fits into; Screw
www.HunterFan.com 1.888.830.1326 11 M0069-01 • 04/30/13 • © Hunter Fan Company Canopy Lift the canopy into place so that the screw holes are aligned. Position the canopy so that, when lifted into place, the canopy fits into the hanging bracket as shown. Screw Holes Insert the two canopy screws found...
Page 12 - Blades
www.HunterFan.com 1.888.830.1326 M0069-01 • 04/30/13 • © Hunter Fan Company Blades Your blades are shielded with Dust Armor® which is a nanotechnology coating that repels dust. For cleaning the fan, use soft brushes or cloths to prevent scratching. Cleaning agents may damage the finishes. 12 Insert ...
Page 13 - Switch Housing
www.HunterFan.com 1.888.830.1326 Feed the wire plug through the center hole of the upper switch housing, then wrap keyhole slots around the screws and twist counterclockwise. Screw two (2) housing assembly screws from the hardware bag halfway into the motor housing. It does not matter which two scre...
Page 14 - Light Kit; Switch; Want to install your fan without a light kit?; “How do I install my fan without the light kit?”
www.HunterFan.com 1.888.830.1326 Connect the plugs from the upper and lower switch housings. Make sure to line up the colored markings on the connectors. Partially install two of the switch housing screws found in the bag. Align the notches in the sides of the lower switch housing with the screws on...
Page 15 - Bulb
www.HunterFan.com 1.888.830.1326 Light Kit (continued) Install a light bulb in each socket. Note: Do not use CFL bulbs to replace your light bulbs. Your lights may flicker or fail to work. Note: Glass shade style and number of lights may vary. See next page for fan operation instructions. Connect th...
Page 16 - Remote Control; ON; Within 3 minutes; the High button for at least 4 seconds. Your
www.HunterFan.com 1.888.830.1326 Remote Control ON Turn P ow er Note: The remote must be paired before the fan will operate. Within 3 minutes of restoring power to the fan, press both the Fan Off button and the High button for at least 4 seconds. Your fan will turn on low to indicate successful sync...
Page 17 - Light Chain
www.HunterFan.com 1.888.830.1326 Remote Control (continued) CONGRATULATIONS! YOU’RE DONE! Push the light button on the remote transmitter. Pull the light chain once. If the light does not turn on, repeat step. Push the 3 button on the remote transmitter for high fan speed. Pull the fan speed chain u...
Page 19 - For cleaning the fan, use soft brushes or
www.HunterFan.com 1.888.830.1326 M0069-01 • 04/30/13 • © Hunter Fan Company 19 For cleaning the fan, use soft brushes or cloths to prevent scratching. Cleaning products may damage the finishes. Safe-Exit • Press the Fan Off button for at least three seconds to initiate the Safe-Exit Mode. • The ligh...
Page 20 - Troubleshooting; the specifications on the light; Fan doesn’t work; Make sure power switch is on.; Excessive wobbling; Install a fresh batter y.; Noisy operation
www.HunterFan.com 1.888.830.1326 M0069-01 • 04/30/13 • © Hunter Fan Company 20 Troubleshooting Lights dim when turned on or do not turn on at all. • Make sure the wattage of the light bulbs installed matches the specifications on the light sockets. Fan doesn’t work • Make sure power switch is on. • ...