Page 2 - Cautions and Warnings; Welc om e
2 45030-01 • 09/11/09 • Hunter Fan Company Table Of Contents 1 • Getting Ready . . . . . . . . . . . . . . . . . . . . . . 4 2 • Installing the Ceiling Plate . . . . . . . . . . 5 3 • Assembling and Hanging the Fan . . . 6 4 • Wiring the Fan . . . . . . . . . . . . . . . . . . . . . 7 5 • Installing...
Page 3 - Inst al ler’s Choice and O ptional Ac ce ss orie s
3 45030-01 • 09/11/09 • Hunter Fan Company Understanding Mounting and Installer’s Choice ® Hunter’s patented 3-position mounting system provides you maximum installation flexibility and ease. You can install your Hunter fan in one of three ways, depending on ceiling height and your preference: Low P...
Page 4 - To install a ceiling fan, be sure you can do the following:; Gathering the Tools; You will need the following tools for installing the fan:; Checking Your Fan Parts; • Gettin g R eady
4 45030-01 • 09/11/09 • Hunter Fan Company To install a ceiling fan, be sure you can do the following: • Locate the ceiling joist or other suitable support in ceiling.• Drill holes for and install wood screws.• Identify and connect electrical wires.• Lift 40 pounds. If you need help installing the f...
Page 5 - • Inst al lin g th e C ei lin g Pl at e
5 45030-01 • 09/11/09 • Hunter Fan Company CAUTION: To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fa...
Page 6 - WARNING: Fan may fall if not assembled as directed in these; CAUTION: The adapter has a special coating on the threads. Do; • A ssemblin g and Han g in g th e Fan
6 45030-01 • 09/11/09 • Hunter Fan Company Steps 3-5 – 3-6 Low Profile Screw Low Profile Washer Steps 3-2 – 3-3 Downrod Canopy Canopy Trim Ring Setscrew WARNING: Fan may fall if not assembled as directed in these installation instructions. 3-1. Unbundle the wires from the fan.For Standard or Angled ...
Page 7 - Single Switch Wiring:; • The black wire (ungrounded) from the ceiling to the black; CAUTION: Be sure no bare wire or wire strands are visible after; ceiling plate into the outlet box.; • Wirin g th e Fan
7 45030-01 • 09/11/09 • Hunter Fan Company All wiring must be in accordance with national and local electrical codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified electrician.Wall switches are not included. Select an acceptable general-use switch in accordance with national an...
Page 8 - • Inst al lin g th e C anopy and C anopy Trim Rin g
8 45030-01 • 09/11/09 • Hunter Fan Company 5-1. Holding the canopy, raise the fan off the hook.5-2. Align the slots in the canopy with the tabs on the ceiling plate.5-3. Raise the canopy over the ceiling plate. Rotate the canopy clockwise until the tabs on the ceiling plate totally engage with the s...
Page 9 - • A ssemblin g th e Bl ade s
9 45030-01 • 09/11/09 • Hunter Fan Company Hunter fans use several styles of fan blade irons (brackets that hold the blade to the fan).6-1. Your fan may include blade grommets. If your fan has grommets, insert them by hand into the holes on the blades. 6-2. Attach each blade to a blade iron using th...
Page 10 - WARNING: Use only the light fixture supplied with this fan model.; assembly screws into the switch housing mounting plate.; CAUTION: Make sure the upper switch housing is securely; If you do not want to install the light fixture, you need to
10 45030-01 • 09/11/09 • Hunter Fan Company Your Hunter fan comes with an integrated light fixture assembly and an optional switch housing cap and plug button. This feature gives you the option of installing the fan with OR without the included light fixture. The steps below direct you whether or no...
Page 11 - Note: In compliance with US federal energy regulations, this
11 45030-01 • 09/11/09 • Hunter Fan Company Lower Switch Housing Plug Connector Housing Assembly Screw Plug Connector Detail Steps 7-6 – 7-7 7-6. To attach the lower switch housing, connect the upper plug connector from the motor to the lower plug connector in the lower switch housing assembly. Note...
Page 12 - Installing the Glass Bowl; -13. Place the cover plate up against the
12 45030-01 • 09/11/09 • Hunter Fan Company Installing the Glass Bowl 7-8. First install B10 candelabra bulbs (60 Watt Maximum) into the sockets. 7-9. Attach the extra pull chain (included) to the fan pull chain using the plastic breakaway connector. (You may find the plastic breakaway connector on ...
Page 13 - Uninstalling the Light Fixture
13 45030-01 • 09/11/09 • Hunter Fan Company Uninstalling the Light Fixture 7-15. To uninstall the light fixture, first disconnect the plug connectors between the black wire and the red wire. 7-16. Disconnect the plug connectors between the two white wires. 7-17. Uninstall the connector and washer fr...
Page 14 - • O p eratin g and Cleanin g Your C ei lin g Fan
14 45030-01 • 09/11/09 • Hunter Fan Company In warm weather, use downward air flow pattern In cold weather, use upward air flow pattern 8-1. Turn on electrical power to the fan.8-2. The fan pull chain controls power to the fan. The pull chain has four settings in sequence: High, Medium, Low, Serenit...
Page 15 - Problem: Lights dim when turned on or do not turn on; Check to make sure wattage of light bulbs installed match the; Problem: If the light on this fan shuts off suddenly.; • Trouble sho otin g
15 45030-01 • 09/11/09 • Hunter Fan Company Problem: Nothing happens; fan does not move. 1. Turn power on, replace fuse, or reset breaker.2. Loosen canopy, check all connections according to the wiring the fan section. 3. Check the plug connection in the switch housing.4. Push motor reversing switch...