Page 2 - TABLE OF CONTENTS
2 3 Congratulations! Your new CTC thermostat will provide years of reliable service. Using this digital ther- mostat will provide more uniform comfort in your home through the seasons. Thank you for buying a Climate Technology product! Please read this manual for complete instructions on installing ...
Page 3 - IMPORTANT INFORMATION; What You Need; INSTALLATION; Remove Old Thermostat; instructions carefully. Wires must be labeled prior to removal.; Figure 1
4 5 1.This thermostat is designed to work on the following systems: • Single-Stage Heat Pump • Mulit-stage Heat Pump (up to 2 heating and 2 cooling) 2.Temperature Range This thermostat can be set between 45°F and 95°F (7°C and 35°C).However, it will display room temperatures from 30°F to 99°F (0°C a...
Page 4 - If the terminal letter
6 7 Wire Labeling • CAUTION! TURN OFF POWER TO THE HEAT PUMP SYSTEM BEFORE YOU ATTEMPT TO ACCESS THE THERMOSTAT’S WIRING. • IMPORTANT! BEFORE DISCONNECTING ANY WIRES FROM THE EXISTING THERMOSTAT, APPLY THE PROVIDED SELF-ADHESIVE LABELS TO THE WIRES. • Use the information in Table 1 below and the pro...
Page 5 - Mount Wallplate; Figure 2; Release Tab
8 9 Mount Wallplate • Remove the wallplate from the thermostat by pressing the release tab on the bottom of the thermostat. See Figure 2. Figure 2 • Position wallplate on wall and pull existing wires through the large opening, then level for appearance. If the existing mounting holes from the old wa...
Page 6 - Connect Wires and Mount Thermostat to Wallplate; Figure 4; your system or thermostat.
10 11 1 2 HE HG F C Connect Wires and Mount Thermostat to Wallplate • Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate. See Figure 4. Ignore any wires which may be present, but which were not connected to the old thermostat. Figure 4 Terminal Screws • Be ...
Page 8 - Switches and Buttons; system’s operation and status.
14 15 system off cool heat fan autorefresh on reset filter em heat sys em aux A B C D E F G H Switches and Buttons Switches and Buttons A LCD Readout - displays indoor temperature, set temperature, and information about the heat pump system’s operation and status. B System Switch - “em heat” is the ...
Page 10 - OPERATION; Change the Set Temperature; Heating or Cooling; fan
18 19 system off cool heat em heat OPERATION Change the Set Temperature 1. Press and hold either the Up or Down button for more than one second. The LCD Display will show “temp”, “set”, the set temperature. 2. To raise the Set Temperature, press the Up button. To lower the Set Temperature, press the...
Page 11 - TROUBLESHOOTING; Problem; reset
20 21 To set the Residual Cooling Fan Delay: 1. Press the Up and Down buttons at the same time again and hold them for three seconds. The LCD Display will show “cool”, “set”, and the current Residual Cooling Fan Delay time in seconds (0, 30, 60, or 90). 2. Press the Up button to increase the Residua...
Page 12 - WIRING DIAGRAM
22 23 TROUBLESHOOTING Problem Solution System continues to op- erate in the Off position 1. Replace thermostat. 1. Replace thermostat. Thermostat permanently reads “HI”, “LO” or “E1” after pressing the Reset button If you experience any other problems with your CTC thermostat, call CTC Technical Sup...
Page 13 - Climate Technology Corp.; A Hunter Fan Company
24 Climate Technology Corp. 2500 FRISCO AVENUE MEMPHIS, TN 38114 © 2006, Climate Technoogy Corp. A Hunter Fan Company Form No. 41982-01, 03/31/06