Page 2 - Table of Contents; Introduction
43006-01 2 Table of Contents Introduction ............................................................................................... 2 Safety Instructions .................................................................................... 3 Description of Air Sterilization System How the Air S...
Page 3 - SAFETY INSTRUCTIONS; READ ALL INSTRUCTIONS BEFORE USING THIS Air Sterilizer.; READ AND SAVE ALL INSTRUCTIONS; place the Air Sterilizer on a firm level floor.; To reduce the r isk of electr ic shock, do not per for m any ser vic ing; CAUTION
43006-01 3 SAFETY INSTRUCTIONS IMPORTANT! READ ALL INSTRUCTIONS BEFORE USING THIS Air Sterilizer. READ AND SAVE ALL INSTRUCTIONS 1. This Air Sterilizer is designed for use on a flat level floor and may not work properly on an uneven floor. ALWAYS place the Air Sterilizer on a firm level floor. ALWAY...
Page 4 - Description of Air Sterilization System; Fig. 1 - Illustration of the Air Sterilization System; Main Filter; How the Air Sterilizer Works
Description of Air Sterilization System 43006-01 4 Fig. 1 - Illustration of the Air Sterilization System Fig. 2 - Air Sterilizer Components Main Filter pre-Filter Top Cover Base Unit How the Air Sterilizer Works Front Back Air Sterilizer Components pre-Filter patented Germicidal Technology Main Filt...
Page 5 - Fig. 2 - Air Sterilizer Controls and Indicators; Controls and Indicators
Description of Air Sterilization System 43006-01 5 Fig. 2 - Air Sterilizer Controls and Indicators Fan Speed Control Dial Fan Speed Control Dial (Top Cover Removed) pre-Filter Reset Button Main Filter Reset Button Fault Indicator off High Medium Low Controls and Indicators power Indicator
Page 6 - Initial operation; The power cord has a three-prong grounded plug, and must be used with; Place the unit on a firm level floor.; Cleaning Your Air Sterilizer; NOTES; pre-Filter and Main Filter Information; you need help finding replacement Main Filters.
43006-01 operation 6 Air Sterilizer Maintenance Initial operation NOTE: The power cord has a three-prong grounded plug, and must be used with an electrical outlet that can accommodate the grounding pin. DO NOT use an adaptor if your power outlet can not accommodate the three-prong grounded plug. DO ...
Page 7 - Air Sterilizer Maintenance; Filter Life Counters; should change the Main Filter.; Cleaning the pre-Filter and Changing the Main Filter; Turn off and unplug the Air Sterilizer.
Air Sterilizer Maintenance 43006-01 7 Filter Life Counters When the Pre-Filter Life Counter exceeds 1400 hours, the Pre-Filter Indicator will flash amber as a reminder that you should clean the pre-Filter. When the Main Filter Life Coun- ter exceeds 8000 hours, the Main Filter Indicator will flash a...
Page 8 - not seated correctly in the unit
Air Sterilizer Maintenance Fan Speed Control Dial (Top Cover Removed) pre-Filter Reset Button 43006-01 8 NOTES : • The Air Sterilizer must be unplugged during the cleaning process.• The Pre-Filter will fit into the unit ONLY when oriented correctly. If the Pre-Filter does not slide easily into the u...
Page 9 - Filter has ridges that fit into grooves in the Base.
Air Sterilizer Maintenance 43006-01 9 NOTES : • The Air Sterilizer must be unplugged during the cleaning process.• The Main Filter will fit into the unit ONLY when positioned correctly. The Main Filter has ridges that fit into grooves in the Base. • The Air Sterilizer will not operate if the Main Fi...
Page 10 - Fig. 9 - Resetting the Main Filter Life Counter; or is not installed correctly on the unit.; plug the unit into a standard household electrical outlet.
Air Sterilizer Maintenance 43006-01 10 Fan Speed Control Dial (Top Cover Removed) Main Filter Reset Button 3. Reset the Main Filter Life Counter by pressing the Main Filter Reset Button. See Figure 9. Fig. 9 - Resetting the Main Filter Life Counter NOTES : • Make certain the Pre-Filter, the Main Fil...
Page 11 - Resetting the Air Sterilizer
Air Sterilizer Maintenance 43006-01 11 Resetting the Air Sterilizer In addition to the pre-Filter and Main Filter Indicators, the Air Sterilizer has a red LED Fault Indicator. See Figure 11. Should the Fault Indicator ever come on, reset the Air Sterilizer. 1. Turn off the Air Sterilizer. 2. Unplug ...
Page 12 - Troubleshooting; Problem; correct replacement filters.; Unit has reduced air
Troubleshooting 43006-01 12 Problem Solutions Obtaining Replacement Main Filters To obtain replacement Main Filters for your Air Sterilizer, first determine your model number by looking at the information label on the back of the Air Sterilizer. The model number will be listed on the label. Then, ca...
Page 13 - Warranty; Technical Support; Hunter Fan Company; Continued
Warranty 43006-01 13 Technical Support If you have any additional questions or problems with your Hunter Air Sterilizer, please call 1-888-830-1326, or contact us over the Internet at www.hunterfan.com. Hunter Fan Company Air Sterilizer 5 YEAR LIMITED WARRANTY The Hunter Fan Company makes the follow...
Page 15 - HUNTER FAN CoMpANY
HUNTER FAN CoMpANY 2500 FRISCo AVENUE MEMpHIS, TN 38114, USA ® 43006-01 Printed in China and Taiwan