Page 2 - Listing Label Information/Location; This owner ’s manual; Homeowner Reference Information; Model Number; XXXXXXXX; Read this manual before installing or operating this appliance.
2 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: ___________________...
Page 3 - Safety Alert Key:; • NOTICE: Used to address practices not related to personal injury.; Table of Contents; User Guide
3 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION...
Page 6 - This warranty is void if:; QRWOLPLWHGWRLPSURSHUFKLPQH\RUYHQWLQJLQVWDOODWLRQ; LIMITATIONS OF LIABILITY:; DWLRQRIJODVV
6 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 4021-645C 12-29-10 Page 2 of 2 WARRANTY CONDITIONS: 7KLVZDUUDQW\RQO\FRYHUV++7DSSOLDQFHVWKDWDUHSXUFKDVHGWKURXJKDQ++7DXWKRUL]HGGHDOHURUGLVWULEXWRU$OLVWRI ++7DXWKRUL]HGGHDOHUVLVDYDLODEOHRQWKH++7EUDQGHGZHEVLWHV 7KLVZDUUDQW\LVRQO\YDOLGZKL...
Page 7 - NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.; Listing and Code Approvals; Models
7 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 C. BTU Specifi cations This product is listed to ANSI standards for “Vented Gas Appliance Heaters” and applicable sections of “Gas Burn-ing Heating Appliances for Manufactured Homes and Recreational Vehicles”, and “Gas Fired Appliances f...
Page 8 - T h e f o l l o w i n g r e q u i r e m e n t s r e f e r e n c e va r i o u s
8 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned ...
Page 9 - A. Gas Fireplace Safety; WARNING; HOT SURFACES; touch glass until it is cooled; Operating Instructions
9 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Figure 2.1 General Operating Parts B. Your Fireplace WARNING! DO NOT operate fi replace before read-ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or inju...
Page 10 - RATING PLATE
10 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 C. Clear Space WARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat ...
Page 11 - J. Before Lighting Fireplace; have a; I. Control Module Operation; Module Reset; Nine Hour Safety Shutdown Feature
11 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 J. Before Lighting Fireplace Before operating this fi replace for the fi rst time, have a qualifi ed service technician : • Verify all shipping materials have been removed from inside and/or underneath the fi rebox. • Review proper plac...
Page 12 - NOT FOR USE; Final inspection by
12 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 K. Lighting Instructions (IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. 2. Wait fi ve (5) minutes to clear out any gas. Then smell for gas, incl...
Page 13 - ISSUE; Condensation on the glass
13 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 L. After Fireplace is Lit Initial Break-in Procedure • T h e f i r e p l a c e s h o u l d b e r u n t h r e e t o f o u r h o u r s continuously on high. • Turn the fi replace off and allow it to completely cool. • Remove fi xed glass ...
Page 14 - Maintenance and Service; Tools needed; Glass Cleaning; Tools Needed
14 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 3 3 Maintenance and Service A. Maintenance Tasks-Homeowner The following tasks may be performed annually by the homeowner. If you are uncomfortable performing any of the listed tasks, please call your dealer for a service ap-pointment. ...
Page 16 - Burner Ignition and Operation
16 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Figure 3.1 IPI Pilot Flame Patterns Burner Ignition and Operation Frequency: Annually By: Qualifi ed Service Technician Tools needed: Protective gloves, vacuum cleaner, whisk broom, fl ashlight, voltmeter, indexed drill bit set, and a m...
Page 17 - A. Typical Appliance System; Getting Started; Installer Guide
17 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 A. Typical Appliance System NOTICE: Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual. Figure 4.1 Typ...
Page 18 - Read all of the instructions before starting the instal-; C. Tools and Supplies Needed; • Installation and use of any damaged appliance or vent; Any such action may cause a fi re hazard.
18 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 B. Design and Installation Considerations Heatilator direct vent gas appliances are designed to op-erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside ...
Page 19 - Framing and Clearances; A. Selecting Appliance Location; Dimensions below refer to a framed wall on
19 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 5 5 Framing and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). WARNING! Risk of Fire or Burns! Provide adequate clear...
Page 20 - B. Constructing the Appliance Chase; • Insulation and other materials must be secured to prevent; * MINIMUM FRAMING DIMENSIONS
20 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 C B D A B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: Treatment of ceilin...
Page 21 - D. Mantel and Wall Projections; Combustible Mantel Legs or Wall Projections
21 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 D. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear-ances as specifi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of non-combustible materials (i.e., ste...
Page 22 - Non-Combustible Mantel Projections; NOT; MATERIAL; Combustible Mantel Projections
22 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 6 12 10 18 21 FIREPLACE OPENING 1-1/4 IN. SEE SECTION 13.D 1/2 IN. NON-COMBUSTIBLE MATERIAL HEIR36HEIR42 MAX. MIN. Note: All measurements in inches. Note: Measurement is taken from top of the opening, NOT the top of the fi replace. Non-...
Page 23 - MODEL; mm; Hearth extension must be non-combustible and
23 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Figure 5.10 Non-Combustible Hearth Extension Dimensions MODEL A B in. mm in. mm HEIR36 12 305 57-1/4 1454 HEIR42 12 305 63-5/16 1608 HEIR50 12 305 71-5/16 1811 A B NON-COMBUSTIBLE NON-COMBUSTIBLE BOARD HEARTH CLEARANCE BRACKET WOOD OR O...
Page 24 - A. Vent Termination Minimum Clearances; Termination Locations; DO NOT; pack air space with insulation or other; NOTICE: HEIR50 Models Only
24 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 A. Vent Termination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0*Over 6/12 to 7/12 .................................................1.25*Over 7/12 to 8/12 ...........
Page 25 - public; Covered Alcove Applications; pass; permitted in screened; HEIR50 is not approved for use with vinyl siding or vinyl soffi ts.
25 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 O N P R Q C J B D B F B A E V V V V V V M H or i V G X V H A V V H Electrical Service V K V K V L C V Figure 6.3 Minimum Clearances for Termination X = AIR SUPPLY INLET A = 12 inches.................clearances above grade, veranda, porc...
Page 26 - Vent Information and Diagrams; D. Measuring Standards; Horizontal
26 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 A. Approved Pipe This appliance is approved for use with Hearth & Home Technologies DVP venting systems. Refer to Section 16.B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufactur...
Page 27 - One Elbow; • Install wall shield and ceiling fi restops as specifi ed.; Minimum; After V; DO NOT attach elbow directly to the appliance.
27 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 H 1 V 1 1. Top Vent - Horizontal Termination Figure 7.3 One Elbow Fire Risk. Explosion Risk. Do NOT pack insulation or other combustibles between ceiling fi restops. • ALWAYS maintain specifi ed clearances around venting and fi restop s...
Page 28 - Two Elbows; Flue restrictor is permit-
28 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 H 2 H 1 INSTALLED HORIZONTALLY V 1 Figure 7.4 Two Elbows Note: Flue restrictor is permit- ted ONLY on 30 ft. minimum vertical runs with no elbows. WARNING! Risk of Fire! • HEIR36(NG/LP), HEIR42(NG/LP) and HEIR50(NG/LP) models require a ...
Page 29 - Three Elbows; must be adhered to.; and V; cannot exceed 60 ft Maximum
29 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 1. Top Vent - Horizontal Termination - (continued) Figure 7.5 Three Elbows HEIR36 (NG/LP), HEIR42 (NG/LP), HEIR50 (NG/LP) V 1 H 1 V 2 H 2 2 ft 610 mm 7 in 178 mm * H 2 Max = 2 X V 2 3 ft 914 mm 2 ft 610 mm * H 2 Max = 2 X V 2 4 ft 1.2 m...
Page 30 - No Elbow; Flue Restrictor
30 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 2. Top Vent - Vertical Termination No Elbow Figure 7.6 V 1 = 50 ft. Max. (15.2 m) V 1 = 2 ft. Min. (610 mm) NOTE: Flue Restrictor ships in manual bag assembly. Note: Flue restrictor is permit- ted ONLY on 30 ft. minimum vertical runs wi...
Page 31 - ELBOWS
31 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Figure 7.8 HEIR36 (NG/LP), HEIR42 (NG/LP), HEIR50 (NG/LP) V 1 H 1 V 2 2 ft 610 mm 1 ft 305 mm * 3 ft 914 mm 3 ft 914 mm * 4 ft 1.2 m 4 ft 1.2 m * 5 ft 1.5 m 9 ft 2.7 m * 6 ft 1.8 m 12 ft 3.7 m * V 1 + V 2 + H 1 = 50 ft (15.2 m) Max. *No...
Page 32 - and H
32 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Three Elbows HEIR36 (NG/LP), HEIR42 (NG/LP), HEIR50 (NG/LP) V 1 H 1 H 2 V 2 H t Max. 2 ft 610 mm * * ** 7 in 178 mm 3 ft 914 mm * * ** 2 ft 610 mm 4 ft 1.2 m * * ** 4 ft 1.2 m 5 ft 1.5 m * * ** 8 ft 2.4 m 6 ft 1.8 m * * ** 12 ft 3.7 m 7...
Page 34 - A. Pipe Clearances to Combustibles; Vent Clearances and Framing; B. Wall Penetration Framing; Combustible Wall Penetration; • The opening must be framed on all four sides using the; Non-Combustible Wall Penetration
34 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 A* B 10 in. 12 in. DO NOT PACK WITHINSULATION OR OTHERMATERIAL A. Pipe Clearances to Combustibles WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops• B...
Page 35 - C. Install the Ceiling Firestop; A ceiling fi restop; MUST; be used between; DVP pipe only; • Frame the area with the same sized lumber
35 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/fl oor (see Figure 8.3). • Frame ...
Page 36 - D. Install Attic Insulation Shield; Flat Ceiling Installation; Vaulted Ceiling Installation; Gas
36 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 D. Install Attic Insulation Shield WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home Technologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and NFPA 54...
Page 37 - Appliance Preparation; NOTICE: This appliance is top vented ONLY.
37 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 9 9 Appliance Preparation A. Vent Preparation Figure 9.2 Seal Cap and Gasket Location SEAL CAP SEAL CAP GASKET GASKET CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal-lation. She...
Page 38 - B. Securing and Leveling the Appliance
38 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Figure 9.3 Side Nailing Tab in Shipping Position Figure 9.4 Nailing Tab Bent Out for Installation HEAT SHIELD NAILING TAB IN SHIPPING POSITION Figure 9.5. Heat Shields and Nailing Tabs in Installation Position B. Securing and Leveling t...
Page 39 - C. Installing Non-combustible Facing Material; • No materials may be substituted without authorization
39 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Figure 9.6 Shipping Location of Non-Combustible Board C. Installing Non-combustible Facing Material WARNING! Risk of Fire!• Follow these instructions exactly.• Facing materials must be installed properly to prevent fi re. • No materials...
Page 40 - A. Assemble Vent Sections; Attach Vent to the Firebox Assembly; The end of the pipe sections with the lanced tabs will face; Assemble Pipe Sections; Make sure that the seams are not aligned to prevent; INCORRECT; Lances
40 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 10 10 Installing Vent Pipe (DVP Pipe) A. Assemble Vent Sections Attach Vent to the Firebox Assembly Note: The end of the pipe sections with the lanced tabs will face toward the appliance. Attach the fi rst pipe section to the starting c...
Page 41 - C. Disassemble Vent Sections
41 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 120º Figure 10.5 Securing Vertical Pipe Sections 120º Figure 10.6 Securing Horizontal Pipe Sections C. Disassemble Vent Sections • Rotate either section (see Figure 10.7) so the seams on both pipe sections are aligned as shown in Figure...
Page 42 - D. Install Metal Roof Flashing; E. Assemble and Install Storm Collar; CAULK
42 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 D. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.9) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the roof a...
Page 43 - F. Install Vertical Termination Cap; Heat shields may not be fi eld constructed.; G. Heat Shield Requirements for Horizontal; • DO NOT remove the heat shields attached to the; H. Install Horizontal Termination Cap
43 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.13 Figure 10.13 TERMINATION CAP F. Install Vertical Termination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while...
Page 44 - • Purge should be performed by qualified service; Gas Information; Gas Pressure; • If substituting for these components, please consult; D. High Altitude Installations
44 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home Technologies specifi ed and approved parts. B. Gas Pressure • Opti...
Page 45 - Electrical Information; A. Wiring Requirements; Ignition System Wiring; C. Optional Accessories Requirements
45 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 12 12 Electrical Information Figure 12.1 IPI Wiring Diagram TO JUNCTION BOX (110V) MODULE I S FLAME SENSE IGNITER GROUND ORANGE (PILOT) GREEN (MAIN) BROWN BLACK RED BATTERY PACK 6V DC FLAME MODULATION ORANGE WHITE TO CUSTOMER-SUPPLIED W...
Page 46 - D. Electrical Service and Repair; If the box is being wired from the; INSIDE; • The junction box is accessible through the front left; ACCESS THROUGH LEFT COLUMN
46 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Figure 12.3 Junction Box Detail NOTICE: DO NOT wire 110 VAC to wall switch. GRN wire inside box Copper groundattached to GRN screw with GRN wire WHT WHT BLK BLK 14/2WG Romex Connector D. Electrical Service and Repair WARNING! Risk of Sh...
Page 47 - Finishing; A. Finishing Templates; Template installation instruction; TOP FINISHING
47 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 13 13 Finishing A. Finishing Templates Two side fi nishing templates and one top fi nishing template are supplied with the appliance. They are fastened to the top surround. INSIDE FIT Method: The fi nishing template pieces are required ...
Page 48 - Slide side tabs into slots by sides of glass.
48 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Figure 13.6. Splatter Guard Installation B. Splatter Guard The splatter guard is a piece of corrugated material used to protect the appliance during the installation process before fi nishing work on the whole hearth is complete. Splatt...
Page 49 - C. Mantel and Wall Projections
49 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 C. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear-ances as specifi ed. Framing closer than the minimums listed must be constructed entirely of non-combustible materials (i.e., steel studs, concrete boar...
Page 52 - Finishing templates are included with this product.
52 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 FINISHING MATERIAL FINISHING MATERIAL IF FINISHING MATERIAL IS THICKER THAN 1-1/2 IN. DOORS WILL ONLY OPEN AS FAR AS PICTURED 1-1/2 IN. MEASURE FROM FIREPLACE OPENING Figure 13.16 Minimum Side Clearance for Operable Doors A B COMBUSTIBL...
Page 53 - Apply the lava rock and Mystic Embers as shown in; Appliance Setup; F. Glowing Ember Placement; • Embers CANNOT be placed directly over ports. Care; APPLY GLOWING EMBERS
53 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 A. Remove Fixed Glass Assembly See Section 14.H. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi ...
Page 55 - Locate log placement notches on bottom of Log #3. See Figure 6. Place; GRATE
55 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Figure 8 Log #4 (2284-704) : See Figure 8. Place Log #4 in appliance with burned edge facing center. The bottom of Log #4 will rest on bottom refractory. Slide bottom of Log #4 forward until it contacts back side of Log #2. Log should a...
Page 57 - LOG PLACEMENT INSTRUCTIONS
57 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Log Set Assembly: LOGS-HEIR50 Models: HEIR50T, HEIR50H LOG PLACEMENT INSTRUCTIONS CAUTION: Logs are fragile, handle with care. Log #1 (2285-701) : Locate log placement notch on the bottom of log #1. See Figure 2. Mate notch on the botto...
Page 58 - and also be about 1/4 inch from right side refractory.; LOG CONTACTS
58 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Log #5 (2285-705) : Locate notched area on Log #1 that will be used to position Log #5. See Figure 2. Place Log #5 into appliance with “burned” edge toward center of appliance. See Figure 11. Log will sit on bottom refractory and should...
Page 60 - H. Fixed Glass Assembly; Removing Fixed Glass Assembly; The glass clip removal/installation tool is fastened to; Glass Weights
60 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Figure 14.4. Glass Clip Tool Location Figure 14.5 Inserting Glass Clip Tool Figure 14.3. Glass Clip Tool H. Fixed Glass Assembly WARNING! Risk of Asphyxiation! Handle fi xed glass assembly with care. Inspect the gasket to ensure it is u...
Page 61 - Replacing Fixed Glass Assembly
61 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 TOP RETAINING RAIL NOTCH TOP RETAINING RAIL NOTCH GLASS FRAME NOTCH GLASS FRAME NOTCH Figure 14.6 Figure 14.8. Replacing Fixed Glass Assembly This fi xed glass assembly is held in place by two side clips, one top retaining rail and lowe...
Page 62 - I. Air Shutter Setting; Visually, a propane fl ame may differ from a natural
62 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 I. Air Shutter Setting Air shutter settings should be adjusted by a qualifi ed ser-vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical ...
Page 63 - Troubleshooting; A. IntelliFire PlusTM Ignition System; Symptom
63 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 15 15 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualifi ed service techni...
Page 65 - Reference Materials; A. Appliance Dimension Diagram; Location Inches
65 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 16 16 Reference Materials Appliance Dimensions Table HEIR36 A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Figure 16.1 Applian...
Page 67 - B. Vent Components Diagrams
67 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 B. Vent Components Diagrams Figure 16.3 DVP vent components 10-1/2 in.(267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in.(289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in.(337 mm) 1/2 in. TYP DVP90ST (90° Elbow) 10 in....
Page 68 - Horizontal Termination Cap; The heat shield is designed to be
68 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal Termination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is ...
Page 70 - Optional Wire Harness; Power Vent Inline
70 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW VerticalTermination Cap (Highwind) PVK-80 (Approved for HEIR36, HEIR42, HEIR50) 11-1/2 in. (292 mm) 12-1/2 in. (318 mm) 16 in. (406 mm) 9 in. (229 mm) 2-3/...
Page 71 - ITEM; Log Set Assembly; Beginning Manufacturing Date: May 2012
71 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Service Parts IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer....
Page 75 - Beginning Manufacturing Date: June 2012
75 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Service Parts IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer....
Page 78 - Qty 2 req
78 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Service Parts Beginning Manufacturing Date: May 2012 Ending Manufacturing Date: Active HEIR36, HEIR42, HEIR50 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model num...
Page 79 - D. Contact Information; For the location of your nearest Heatilator dealer,; DO NOT DISCARD THIS MANUAL; NOTICE; • Leave this manual with
79 Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12 Heatilator, a brand of Hearth & Home Technologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www.heatilator.com D. Contact Information Please contact your Heatilator dealer with any questions or concerns. For the location of ...