Page 2 - Table of Contents; GC150 SERIES DIRECT VENT GAS APPLIANCE
Table of Contents I. Listings and Code Approvals.....................................................................................................................3 II. Description of the Fireplace System.................................................................................................
Page 3 - I. LISTINGS AND CODE APPROVALS; II. DESCRIPTION OF THE FIREPLACE SYSTEM
1-99 3 21322L I. LISTINGS AND CODE APPROVALS Certification The GC150 Series Vented Gas Fireplace has beentested in accordance with the ANSI standard ANSIZ21.50-1998 l CGA 2.22-M98 and has been listed by Warnock Hersey for installation and operation asdescribed in these Installation and OperatingInst...
Page 4 - III. FIREPLACE SYSTEM COMPONENTS; if elbow used, 1st elbow must be one of these
Catalog Number Description GC150 34" natural gas, standing pilot, heat circulating fireplace GC150E 34" natural gas, electronic ignition, heat circulating fireplace(Natural gas models may be converted to propane gas using the CKPconversion kit) CKP Natural gas to propane gas conversion kit B...
Page 6 - C. FIREPLACE LOCATIONS AND; DO NOT EXPOSE THE UNIT TO THE
2-99 6 21322L INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THE APPLIANCESHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE PERSON.MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BED-DING MATERIAL, ETC. IT IS IMPERATIVE TH...
Page 7 - E. FRAMING THE FIREPLACE; The outside walls of the home around the
12-98 7 21322K GC150 SERIES DIRECT VENT GAS APPLIANCE E. FRAMING THE FIREPLACE F. FINISHING MATERIALS The GC150 Series Gas Appliance will fit a framedopening of 40" w X 16 1 ⁄ 2 " d X 30 1 ⁄ 8 " h. Only non-combustible materials may be used tocover the black surfaces of the fireplace fro...
Page 8 - A. Horizontal Termination; THE FIREPLACE SYSTEM; WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION.
STEP 1 - Positioning the Firebox This fireplace may be placed on a smooth combustible or non-combustible continuous, flat surface. When the appliance is installed directly on carpeting, tile or other combustible materialother than wood flooring, the appliance shall be installed on ametal or wood pan...
Page 11 - B. Vertical Termination
12-98 11 21322K GC150 SERIES DIRECT VENT GAS APPLIANCE To install the termination cap, slide the cap ventsections into the vent sections as shown in Figures10A and 10B. Secure the cap flush to the wallusing the eight 1" fasteners provided. Seal the capto the wall with a mastic such as silicone c...
Page 18 - DO NOT HIT, STRIKE OR SLAM SHUT THE
Figure 30 Placing the Rock Wool Figure 31 Glass Replacement Figure 32 Lower Panel Replacement Figure 29 - Placing the Lava Rock and Vermiculite 12-98 18 21322K GC150 SERIES DIRECT VENT GAS APPLIANCE STEP 13 - Placing the Lava Rock, Vermiculite andRock Wool Spread the lava rock over the area in front...
Page 19 - VI. OPERATING INSTRUCTIONS; FOR YOUR SAFETY READ BEFORE LIGHTING; LIGHTING INSTRUCTIONS; TO TURN OFF GAS TO APPLIANCE; STANDING PILOT; STOP! Read the safety information above on this label!
4-99 19 21322M GC150 SERIES DIRECT VENT GAS APPLIANCE VI. OPERATING INSTRUCTIONS A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor...
Page 20 - ELECTRONIC UNITS; Determining the Ignition Type
4-99 20 21322M GC150 SERIES DIRECT VENT GAS APPLIANCE ELECTRONIC UNITS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may resultcausing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It i...
Page 22 - A. STANDING PILOT OPERATION
4-99 22 21322M GC150 SERIES DIRECT VENT GAS APPLIANCE Figure 35 Standing Pilot Ignition Valve “OFF” Figure 36 Standing Pilot Ignition Valve to “PILOT” Figure 38 Standing Pilot Ignition to “ON” Figure 37 Red Ignitor Button A. STANDING PILOT OPERATION 1. Initial and Seasonal Lighting Procedure. Initia...
Page 24 - VII. MAINTENANCE INSTRUCTIONS
12-98 24 21322K GC150 SERIES DIRECT VENT GAS APPLIANCE Cleaning the burner and control compartment Keep the burner and control compartment clean by brushing andvacuuming at least once a year. Always turn off the gas valve andthe ON/OFF switch before cleaning. Checking flame patterns Visually check t...
Page 25 - VIII. TROUBLE SHOOTING
4-99 25 21322M GC150 SERIES DIRECT VENT GAS APPLIANCE VIII. TROUBLE SHOOTING ELECTRONIC IGNITION (GC150E) B. Plugged burner orifice. C. Wall switch defective. D. No Power A. A normal result of gas combustion. A. A normal result during the first 20 minutes ofburning. B. Improper air mixture. 1. Spark...
Page 27 - IX. REPLACEMENT PARTS; ELECTRONIC IGNITION - GC150E
4-99 27 21322M GC150 SERIES DIRECT VENT GAS APPLIANCE IX. REPLACEMENT PARTS Replacement parts are available from your distribu-tor/dealer, or through Heatilator, 1915 W. SaundersStreet, Mt. Pleasant, Iowa 52641. ELECTRONIC IGNITION - GC150E # I g ni ti on c on tr o l i de n ti fi ca t io n m u st be...
Page 28 - STANDING PILOT - GC150; Attention; APPLIANCE; Please return these Operating and Installation Instructions
4-99 28 21322 Rev M STANDING PILOT - GC150 ** If any of the original wir ing as supplied with the appliance must be replaced, it must be replacedwith Type 18 ga., 105C wire, or its equivalent. ITEM PART # DESCRIPTION 1 21427 Burner 2 25660 Pilot Assembly - Natural 3 16752 Orifice - Natural 4 13425 M...